Unusually tight construction is defined as 
construction where:
a.  walls and ceilings exposed to the out-

side  atmosphere  have  a  continuous 
water  vapor  retarder  with  a  rating  of 
one perm (6 x 10

-11

 kg per pa-sec-m

2

) or 

less with openings gasketed or sealed 
and 

b.  weather stripping has been added on 

openable windows and doors and 

c.  caulking  or  sealants  are  applied  to 

areas  such  as  joints  around  window 
and door frames, between sole plates 
and floors, between wall-ceiling joints, 
between  wall  panels,  at  penetrations 
for plumbing, electrical, and gas lines, 
and at other openings. 

If your home meets all of the three criteria 
above, you must provide additional fresh 
air.  See 

Ventilation  Air  From  Outdoors

page 8. 
If your home does not meet all of the three 
criteria  above,  proceed  to 

Determining 

Fresh-Air Flow For Fireplace Location

.

Confined and Unconfined Space

The 

National  Fuel  Gas  Code, ANSI  Z223.1.3/ 

NFPA 54

 defines a confined space as a space whose 

volume is less than 50 cubic feet per 1,000 Btu 

per hour (4.8 m

3

 per kw) of the aggregate input 

rating of all appliances installed in that space and 

an unconfined space as a space whose volume is 

not less than 50 cubic feet per 1,000 Btu per hour 

(4.8 m

3

 per kw) of the aggregate input rating of 

all appliances installed in that space. Rooms com-

municating directly with the space in which the 

appliances are installed*, through openings not 

furnished with doors, are considered a part of the 

unconfined space.
* Adjoining  rooms  are  communicating  only  if 

there are doorless passageways or ventilation grills 

between them.

AIR FOR COMBUSTION 

AND VENTILATION

Continued

DETERMINING FRESH-AIR FLOW 
FOR FIREPLACE LOCATION

Determining if You Have a Confined or 
Unconfined Space

Use this work sheet to determine if you have a 

confined or unconfined space.

Space: 

Includes the room in which you will install 

fireplace plus any adjoining rooms with doorless pas-

sageways or ventilation grills between the rooms.
1.  Determine the volume of the space (length x 

width x height).

 

Length x Width x Height =__________cu. ft. 

(volume of space)

 

Example: 

Space  size  20  ft.  (length)  x  16  ft. 

(width) x 8 ft. (ceiling height) = 2560 cu. ft. 

(volume of space)

 

If  additional  ventilation  to  adjoining  room  is 

supplied with grills or openings, add the volume 

of these rooms to the total volume of the space. 

2.  Multiply the space volume by 20 to determine 

the maximum Btu/Hr the space can support.

 

 __________ (volume of space) x 20 = (Maxi-

mum Btu/Hr the space can support)

 

Example: 

2560 cu. ft. (volume of space) x 20 = 

51,200 (maximum Btu/Hr the space can support)

3.  Add the Btu/Hr of all fuel burning appliances in 

the space.

 

Vent-free fireplace 

 ___________ Btu/Hr

 

Gas water heater* 

 ___________ Btu/Hr

 

Gas furnace 

 ___________ Btu/Hr

 

Vented gas heater 

 ___________ Btu/Hr

 

Gas fireplace logs 

 ___________ Btu/Hr

 

Other gas appliances* + ___________ Btu/Hr

 

Total                            = ___________ Btu/Hr

 

* Do not include direct-vent gas appliances. Di-

rect-vent draws combustion air from the outdoors 

and vents to the outdoors.

 

Example: 

 

Gas water heater 

 ____________ Btu/Hr

 

Vent-free fireplace  + ___________ Btu/Hr

 

Total 

= ___________ Btu/Hr

4.  Compare the maximum Btu/Hr the space can 

support with the actual amount of Btu/Hr used.

 

 _________Btu/Hr (maximum the space can support) 

 

 _________Btu/Hr (actual amount of Btu/Hr used)

 

Example:

  51,200 Btu/Hr (maximum the space 

can support) 

 

 

56,000  Btu/Hr  (actual  amount  of 

Btu/Hr used)

The space in the above example is a confined space 

because the actual Btu/Hr used is more than the maxi-

mum Btu/Hr the space can support. You must provide 

additional fresh air. Your options are as follows:

  30,000
  26,000
  56,000

Содержание Vanguard VMH26TNC

Страница 1: ...SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier MODELS VMH26TPC AND VMH26TN...

Страница 2: ...e rating plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer TABLE OF CONTENTS Safety Information 3 Local Codes 4 Product Identification 4 Product Features 5 Unpacking 5 Assembly 5 Air for Combustion and Ventilation 6 Installation 9 Operating Fireplace 19 Inspecting Burner 21 Cleaning and Maintenance 22 Tro...

Страница 3: ...d proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for us...

Страница 4: ...as an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation page 6 If fireplace keeps shutting off see Troubleshooting page 23 11 Do not run fireplace where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this fireplace to cook food or burn paper or other object...

Страница 5: ...ing damage If fireplace is damaged promptly inform dealer where you bought fireplace ASSEMBLY WARNING Always have branch support and screen in placebeforeoperatingfireplace Thispreventsexcessivetemper atures on fireplace surfaces WARNING Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this fireplace may result in prop erty damage or person...

Страница 6: ... insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy effi cient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fres...

Страница 7: ...Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install fireplace plus any adjoining rooms with doorless pas sageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height __________cu ft volume of space Example Space size 20 ft ...

Страница 8: ... connecting the two spaces see options 1 and 2 Figure 4 You can also remove door into adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts AIR FOR COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills ...

Страница 9: ... mildew to form from too much moisture See Air for Combustion and Ventilation page 6 Note Your Vanguard fireplace is designed to be used in zero clearance installations Wall or framing material can be placed directly against any exterior surface of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed direc...

Страница 10: ...and depth of the fireplace CAUTION If you install the fireplace in a home garage fireplacepilotandburnermustbe at least 18 inches above floor locatefireplacewheremoving vehicle will not hit it For convenience and efficiency install fireplace where there is easy access for operation inspec tion and service in coldest part of room An optional blower kit is available from your dealer see Accessories page 3...

Страница 11: ...connections 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equip ment shutoff valve The flexible gas line must be the last item installed on the gas piping 4 If you have not assembled firebox follow instructions on page 4 5 Carefully set fireplace in front of rough opening with back of fireplace inside wall opening ...

Страница 12: ...le locate outlet so cabinet mantel will cover it when installed see Figure 12 3 Place hearth base against wall at installation location Cut an access hole in hearth base to run gas line to fireplace see Figure 12 Make sure to locate access hole so cabinet mantel will cover it when installed Note You can secure base to floor using wood screws Countersink screw heads and putty over 4 Route flexible gas...

Страница 13: ...n see Figure 16 page 14 2 Using short Phillips screwdriver remove the screw under the center of the branch support Rotate valve cover shield clockwise and slide out IMPORTANT Do not remove shoulder screw on the left side of valve cover shield Slide the valve cover shield off of the shoulder screw see Figure 16 page 14 Note If you do not have a short Phillips screwdriver the screen log set and bran...

Страница 14: ... is in the ON position the fan will run until turned to OFF Reinstall upper louver assembly and hood if previously removed see Figure 15 page 13 Close lower louver door Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors cancauseimproperanddanger ous operation CAUTION Verify proper op eration after servicing Note If you are using a mantel w...

Страница 15: ...supplied will not be used in built in installations Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring harness see Figure 19 5 Plug power cord to the outlet receptacle not provided as shown in Figure 18 Wind the extra power cord and tie ...

Страница 16: ...may be used in certain areas Check your local codes Use pipe of 1 2 or greater diameter to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Installation must include a equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 22 IMPORTANT Install equipment shutof...

Страница 17: ...ce see Figure 23 3 Route flexible gas line included from fireplace control to equipment shutoff valve through side or rear access holes in outer casing NOTICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure23 The flexible gas supply line con nectiontotheequipmentshutoff valve should be accessible CAUTION Avoi...

Страница 18: ...or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply a noncorrosive leak detection fluid to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 ...

Страница 19: ...ICE Duringinitialoperation of new fireplace burning logs will give off a paper burning smell Orange flame will also be present Open window to vent smell Operate fireplace on HI position to burn off odor This will only last a few hours 1 STOP Read the safety information starting in column 1 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5...

Страница 20: ... position 2 Turn off all electric power to the appliance if service is to be performed Shutting Off Burner Only pilot stays lit Turn control knob clockwise to the PILOT position THERMOSTAT CONTROL OPERATION The thermostatic control used on this fireplace differs from standard thermostats Standard ther mostats simply turn on and off the burner The thermostat used on this fireplace senses the room tem...

Страница 21: ... pattern The incorrect pilot flame is not properly heating the thermocouple This will cause the thermocouple to cool When the thermocouple cools the fireplace will shut down If pilot flame pattern is incorrect as shown in Figure 33 turn fireplace off see To Turn Off Gas to Ap pliance page 20 see Troubleshooting page 23 Note The pilot flame on natural gas units will have a slight curve but flame should b...

Страница 22: ...ow position If using com pressed air in a can please follow the directions on the can If you donʼt follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 35 3 Blow air through the ports slots and hole...

Страница 23: ...sition 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pilot assembly 6 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff va...

Страница 24: ... terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas company B Clean ODS pilot see Cleaning and Maintenance page 22 or replace ODS pilot assembly 7 Replace pilot assembly 8 Replace control valve 1 Clean burner see Cleaning and Maintenance page 22 or replace burner ori...

Страница 25: ...nd let warm up for a minute 2 Operate burner until air is re moved from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Clean burner see Cleaning and Maintenance page 22 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products 1 This is common with most fireplaces If...

Страница 26: ...ally clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between con trol valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ven tilation air REMEDY 1 Ventilate room Stop using odor causing products while fireplace is running 2 Refill supply tank 3 Locate and correct all leaks see Checking Gas Connec tions page 18 1 Open window and o...

Страница 27: ...at 1 866 672 6040 for referral information When calling DESA Heating Products have ready your name your address model and serial numbers of your fireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they canʼt supply original r...

Страница 28: ...11 01D 28 ILLUSTRATED PARTS BREAKDOWN MODELS VMH26TPC SHOWN AND VMH26TNC 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14 25 14 40 3 37 26 39 39 5 6 9 ...

Страница 29: ...ator Screw 2 19 Outer Shell Base 1 20 102649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 25 098271 06 Ignitor Cable 1 26 107186 01 Injector 1 107186 02 Injector 1 27 101006 02 Pilot Bracket 1 28 098249 01 Nut M5 2 29 098522 26 Gas Valve 1 098522 23 Gas Valve 1 30 102639 01...

Страница 30: ...nal extruded louver Kit contains 2 louvers THERMOSTATICALLY CONTROLLED BLOWER KIT GA3450TA For all models Provides better heat distribution Makes fireplace more efficient Automatically turns off and on as needed CORNER MANTEL WITH FULL HEARTH BASE Not Shown GMC64FC Series Oak Finished GMC63UC Series Unfinished CS26CP Series 2 Tone Finish Black Lyptus GMC83FA Series Oak Finished Column Style CMA208F S...

Страница 31: ...ent performance problems This kit gives you the tools and instruc tions to make it easy to clean all critical areas of your appliance INFORMATION VIDEO 108917 01 A care and maintenance video is available by calling 1 866 672 6040 You may also email your request to productsupport desaint com FIRE CRACKLE CF6 A Not Shown Creates the sound of a real burning fire ...

Страница 32: ...used by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENTALLOWED BYTHE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WAR...

Отзывы: