background image

www.desatech.com

113195-01A

34

ACCESSORIES

Purchase these fireplace insert accessories from
your local dealer. If they can not supply these ac-
cessories, call DESA Heating Products’ Sales De-
partment at 1-866-672-6040 for information. You
can also write to the address listed on the back
page of this manual.

FIREPLACE SURROUND KIT GS38
AND GS43 BLACK (Surround Kit
Required for Installation)

Allows insert to be fitted to fireplace opening.
A surround is required for installation.

Note:

 Use the accessory which best covers the

existing masonry fireplace opening.
• Model GS38 Surround Kit (for use with fire-

places with an opening smaller than 30" H and
38" W)

• Model GS43 Surround Kit (for use with fire-

places with an opening 30" to 36 

3

/

4

" H and 38"

to 43" W)

EQUIPMENT SHUTOFF VALVE -
GA5010

For all models.

 Equipment shutoff valve with 1/8"

NPT tap. Fits 1/2" NPT pipe.

FIREBOX BRICK LINER - G8010
Series (Not Shown)

Ceramic fiber firebox liner adds the look of real brick.

DUPLEX OUTLET KIT GA3555
(Not Shown)

For built-in installation when accessory blowers
are used.

RECEIVER AND HAND-HELD
THERMOSTAT REMOTE CONTROL
KIT - GHRCTB SERIES

For all models. 

Allows the gas log heater to be

operated in a manually or thermostatically-con-
trolled mode. You can turn the gas log heater on
and off without ever leaving the comfort of your
easy chair.

RECEIVER AND HAND-HELD
REMOTE CONTROL KIT - GHRCB
SERIES

For all models.

 Allows the gas log heater to be

turned on and off by using a hand-held remote
control.

WALL-MOUNT THERMOSTAT
SWITCH GWMT1 (Not Shown)

For all models. 

The desired comfort setting can

be selected on the wall thermostat and the log
heater will automatically cycle from pilot to the
heat setting selected.

WALL-MOUNT ON/OFF SWITCH -
GWMS2 (Not Shown)

For all models. 

Allows the gas log heater to be

turned on and off with a wall switch.

CLEANING KIT - GCK (Not Shown)

For all models. 

Your vent-free gas appliance re-

quires regular cleaning and maintenance to pre-
vent performance problems. This kit gives you the
tools and instructions to make it easy to clean all
critical areas of your appliance.

INFORMATION VIDEO - 108917-01

For all models.

 A care and maintenance video is

available by calling 1-866-672-6040. You may also
email your request to

[email protected].

FIRE CRACKLE - CF6-A
(Not Shown)

For all models. 

Creates the sound of a real burn-

ing fire.

Содержание Vanguard VI33NRB

Страница 1: ...LL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instruct...

Страница 2: ...lled in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance...

Страница 3: ...ide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directly into the fireplace insert Avoid any dra...

Страница 4: ...eeds fresh air ventila tion to run properly This fireplace insert has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place insert if not enough fresh air is avail ab...

Страница 5: ...ve pack ing Note The hood is located in the packing on the right hand side of the heater front Lift the heater off the bottom tray 2 Locate two screws above top corners of the fireplace insert screen...

Страница 6: ...to make your home energy effi cient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces...

Страница 7: ...burning appliances in the space Vent free fireplace __________ Btu Hr Gas water heater __________ Btu Hr Gas furnace __________ Btu Hr Vented gas heater __________ Btu Hr Gas fireplace logs _________...

Страница 8: ...move door into adjoining room see option 3 Figure 3 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or duct...

Страница 9: ...fireplace insert WARNING This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted INSTALLATION Continued ELECTRICAL HOOKUP Blower Accessory This fireplace insert in...

Страница 10: ...ly Make sure each part fits properly Firmly tighten all screws installed during assembly INSTALLATION Continued Figure 5 Removing Screws and Screen Shipping Screw DISCARD Screen Mounting Shoulder Scre...

Страница 11: ...s screws provided to at tach hood to fireplace insert and 2 Phillips screws provided to attach hood and surround sides to fireplace insert Figure 10 Installing Hood to Firebox Screws INSTALLATION CLEA...

Страница 12: ...r connect natural gas fireplace insert to private non utility gas wells This gas is commonly known as wellhead gas Installation Items Needed Before installing fireplace insert make sure you have the i...

Страница 13: ...te sediment trap where trapped mat Figure 13 External Regulator with Vent Pointing Down Propane LP Supply Tank External Regulator Vent Pointing Down ter is not likely to freeze A sediment trap traps m...

Страница 14: ...Line from Fireplace Gas Regulator Provided with Fireplace Insert To Fireplace Gas Regulator Equipment Shutoff Valve Propane LP To External Regulator Natural To Gas Meter CHECKING GAS CONNECTIONS WARN...

Страница 15: ...pply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light fireplace insert see Operating Fireplace Insert page 19 Check all other internal...

Страница 16: ...trim from packaging 2 Locate four 6 screws two adjusting plates with set screws and two shims in the hard ware packet 3 Align shim under adjusting plate as shown in Figure 21 4 Slide one end of adjust...

Страница 17: ...ontact any log If so reposition logs according to the log installation instruc tions in this manual Flames contacting logs will create soot It is very important to install the logs exactly as instruct...

Страница 18: ...STALLING 9 VOLT BATTERIES Two 9 volt batteries not included are required to operate this heater with the wireless hand held remote control set Install one battery in the re ceiver and one in the hand...

Страница 19: ...and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the fireplace insertscreeninplace Makesure fireplace insert screen is in stalled before...

Страница 20: ...URN OFF GAS TO APPLIANCE Shutting Off Heater 1 Turn control knob clockwise to the OFF position 2a Set selector switch in the OFF position 2b If Using Optional Hand Held Remote Set remote selector swit...

Страница 21: ...fully press the C F mode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons to gether to turn on the hand held remote control 2 Press the MANU b...

Страница 22: ...AUTO position the blower will start when the thermostat senses a sufficient increase in firebox temperature Note Your gas logs and thermostat blower will not turn on and off at the same time The fire...

Страница 23: ...ep control areas burner and cir culating air passageways of heater clean Inspect these ar eas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more...

Страница 24: ...er to In stalling Logs page 16 to properly replace logs Replace log s if broken or chipped dime sized or larger BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting a...

Страница 25: ...installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Ke...

Страница 26: ...ly 2 AfterODS pilotlights keepcon trol knob pressed in 30 seconds 3 Fully open equipment shutoff valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenanc...

Страница 27: ...on requirements page 6 1 Turn control knob to LO po sition and let warm up for a minute 2 Operate burner until air is re moved from line Have gas line checked by local natural or propane LP gas compan...

Страница 28: ...Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents af fecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked REMEDY 1 Open wi...

Страница 29: ...chase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heat...

Страница 30: ...01A 30 ILLUSTRATED PARTS BREAKDOWN MODELS VI33NRB AND VI33PRB 17 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 Note Items 27 and 28 a...

Страница 31: ...10 104236 01CK 104236 01CK Painted Base Assy 1 11 M12461 26 M12461 26 Screw 10 x 32 4 12 Firebox Bottom 1 13 103284 03 103284 03 Wiring Harness 1 14 098265 02 098265 02 Elbow Male 1 15 103782 01 10378...

Страница 32: ...w desatech com 113195 01A 32 ILLUSTRATED PARTS BREAKDOWN FIREPLACE INSERT MODELS VI33NRB AND VI33PRB 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 15 23 4 6 6 17 16 18 19 20 21 22 22 23 14 24 25 14 2...

Страница 33: ...05518 01CK Firebox Hood 1 8 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 Firebox Top 1 11 Outer Base 1 12 Firebox Wrapper 1 13 101614 02 Cover and Switch Assembly 1 14 M11084 26 Hex Screw 10 46 1...

Страница 34: ...THERMOSTAT REMOTE CONTROL KIT GHRCTB SERIES For all models Allows the gas log heater to be operated in a manually or thermostatically con trolled mode You can turn the gas log heater on and off withou...

Страница 35: ...____________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________...

Страница 36: ...nce or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the ow...

Отзывы: