INSTALLING
Continued
Continued
Alternate Built-In Attachment Method: Nailing Flange Accessory
If desiring to attach heater to wall studs, use nailing flange accessory.
Note:
You
cannot use brass trim if using the nailing flange.
1. Attach nailing flange accessory to each side of fireplace (see Figure 14). See
Accessories, page 33, for nailing flange.
2. Carefully insert fireplace into rough opening.
3. Attach fireplace to wall studs using nails or wood screws through holes in
nailing flange (see Figure 14).
4. Check all gas connections for leaks. See Checking Gas Connections, page 18.
Figure 14 - Installing and Attaching Nailing Flange Accessory
Nailing Flange
Mantel Shelf
Figure 15 - Minimum Mantel Clearances for Built-In Installation
If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.
Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must meet minimum clearance between
mantel shelf and top of fireplace opening.