background image

www.desatech.com

109005-01C

7

IGNITOR

Make  sure  gap  between  ignitor  electrode  and 

burner nozzle is 0.13/0.15 in (3.3/3.8 mm). Access 

ignitor electrode from inside combustion chamber. 

No other maintenance is needed for ignitor.

SERVICE PROCEDURES

Continued

Figure 8 - Fan Cross Section

Figure 7 - Fan, Motor Shaft and Setscrew 

Location

Setscrew

Motor 
Shaft

Fan

Setscrew

Fan

Hub

Motor Shaft

Figure 6 - Fan Removal

Fan

Motor

REPLACEMENT PARTS

 WARNING: Use only original 

replacement parts. This heater 

must use design-specific parts. 

Do not substitute or use generic 

parts.  Improper  replacement 

parts could cause serious or fa-

tal injuries. This will also protect 

your warranty coverage for parts 

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they 

canʼt  supply  original  replacement  part(s),  call 

DESA Industries at 1-905-826-8010.
When calling DESA Industries, have ready
•  your name
•  your address
•  model number of your heater
•  how heater was malfunctioning
•  purchase date
In most cases, we will ask you to return the part 

to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If 

they canʼt supply original replacement part(s), 

call  DESA  Industriesʼ  Parts  Department  at 

1-905-826-8010.
When calling DESA Industries, have ready:
•  model number of your heater
•  the replacement part number

SPECIFICATIONS

•  150,000 Btu/Hr Input Rating
•  Propane Vapor Fuel Only
•  Fuel Consumption - 1.6 Gal/hr (6 Liters/hr)

  Fuel Consumption - 7.0 lb/hr (26.4 Kg/hr
•  Supply Pressure To Regulator:

  Minimum (for purposes of input adjustment)

  0 psi 69 (kPa), Maximum - Tank Pressure

•  Regulator Outlet Pressure (Factory Preset)

  12.5 in (31.8 cm) WC
•  Manifold Pressure - 9.8 in (24.9 cm) WC
•  Hot Air Output (CFM Approx)  - 15.6 (550)
•  Motor - 3,450 RPM, 1/8 HP
•  Electric Input - 120 V/60 Hz
•  Amperage - 2.2
•  Ignition - Direct Spark, Interrupted Type
•  Ignitor Gap - 0.13/0.15 in (3.3/3.8 mm)

Содержание RCLP155AT

Страница 1: ...or service this heater Ifyouneedassistanceorheaterinformationsuchasanin structions manual labels etc contact the manufacturer Save this manual for future reference For more information visit www desatech com CANADIAN PROPANE CONSTRUCTION FORCED AIR HEATER OWNER S MANUAL MODEL RCLP155AT 150 000 BTU HR WITH BUILT IN THERMOSTAT TABLE OF CONTENTS Safety Information 2 Unpacking 3 Product Identification ...

Страница 2: ... added to propane gas The odor helps you detect a propane gas leak However the odor added to propane gas may fade Propane gas may be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater 1 Install and use heater with care Follow all local ordinances and codes In the absence o...

Страница 3: ...e UNPACKING 1 Remove all packing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT IDENTIFICATION PROPANE SUPPLY Propane gas and propane tank s are to be fur nished by the user...

Страница 4: ...ON WARNING Review and un derstand the warnings in the SafetyInformationsection page 2 They are needed to safely op erate this heater Follow all local codes when using this heater WARNING Testallgaspiping and connections for leaks after installation or servicing Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all ...

Страница 5: ...valve and open again slowly 6 Turn on off switch to the ON position Adjust thermostat to desired setting If heater does not start thermostat setting may be too low Turn thermostat knob to higher position to start heater Note If heater does not start turn on off switch to the OFF position Wait ten seconds for safety control to reset then try again Note If heater still does not start after turning t...

Страница 6: ...egulator assembly before each use If hose is highly worn or cut replace 4 Have heater inspected yearly by a qualified service agency 5 Keep inside of heater free from combustible and foreign objects 6 Clean fan blades each season or as needed see Fan PREVENTATIVE MAINTENANCE SCHEDULE Item How Often How To Fan See Fan SERVICE PROCEDURES WARNING Never service heater while it is plugged in connected t...

Страница 7: ...Industries at 1 905 826 8010 When calling DESA Industries have ready your name your address model number of your heater how heater was malfunctioning purchase date In most cases we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they canʼt supply original replacement part s call DESA Industriesʼ Parts Department at 1 905 826 801...

Страница 8: ...tor page 7 If you see spark at ignitor have heater serviced by qualified service person If no spark seen A Loose or disconnected ignitor wire B Wrong spark gap C Bad ignitor electrode 1 Propane supply may be inad equate 2 High surrounding air tem perature causing thermal limit device to shut down heater 3 Restricted air flow 4 Damaged fan 5 Excessive dust or debris in surrounding area OBSERVED FAULT...

Страница 9: ...k Motor Power Cord 120 VAC On Off Switch Black High Temp Switch Black Thermostat White Green Green T Black Black Line Neutral Green or Green Yellow Black White Green Black White Motor Blue Blue Blue Green Black White Orange Ignitor Solenoid Valve Automatic Ignition System G V VR ACR AC Position of Leads May Vary WIRING DIAGRAM Electrical Connection Diagram Electrical Ladder Diagram ...

Страница 10: ... 10 ILLUSTRATED PARTS BREAKDOWN MODEL RCLP155AT 33 2 1 31 12 26 43 32 10 11 38 20 21 6 7 6 5 3 37 34 Note Screws are standard hardware items 28 7 15 17 27 8 14 36 29 39 4 8 13 25 23 16 42 30 20 35 22 24 18 19 41 44 45 9 40 46 47 ...

Страница 11: ...rmostat Knob 1 31 M51104 01 Handle 1 32 M11084 29 Screw 10 16 x 3 4 2 33 097964 03AA Fan Guard 1 34 101206 01 Motor Relay Support Bracket Assembly 1 35 M11143 1 Strain Relief Bushing 1 36 098219 17 Power Cord 1 37 M50631 Rubber Bumper 2 38 NTC 4C Lock Nut 2 39 099157 01 Break Mandrell Rivet 3 16 1 40 099125 01 Terminal Board 1 41 M12461 25 Screw 10 32 x 1 4 2 42 M10908 1 Screw Hex TPG F 6 32 x 25 ...

Страница 12: ...EU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSE DESA Industries assumes no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you This Limited Warranty gives you specific ...

Страница 13: ...liser ou réparer cet appareil de chauffage Si vous avez besoin d assistance ou de renseignements concernant l appareil de chauffage tels que le mode d em ploi les étiquettes etc communiquez avec le fabricant Conservez ce manuel pour consultation future Pour plus de détails visitez le site www desatech com APPAREIL DE CHAUFFAGE À AIR FORCÉ DE CHANTIER AU GAZ PROPANE POUR LE CANADA MANUEL D UTILISAT...

Страница 14: ...auffagenefonctionnepasbien Respirez toutdesuitedel airfrais Vérifiezsilaventilationest suffisante et faites réviser l appareil de chauffage Gazpropane legazpropaneestsansodeur Unproduit odorantestajoutéaugazpropane Cetteodeurvousper metdedétecterunefuitedegaz Cependant cetteodeur ajoutéeaupropanepeutsedissiper Dugazpropanepeut être présent même s il n y a pas d odeur Lisez et comprenez tous les aver...

Страница 15: ...ubstituts ou de pièces génériques L utilisation de pièces de rechange inadéquates peut causer des blessures graves ou la mort 31 Cet appareil de chauffage est équipé d un ther mostat Il peut donc s allumer à tout moment DÉBALLAGE 1 Enlevez tout matériau d emballage appliqué sur l appareil de chauffage pour son expédition Conservez les bouchons en plastique sur le raccord d entrée et l assemblage d...

Страница 16: ...spourfaire fonctionnercetappareildechauffage sans danger Respectez tous les codes locaux lors de l utilisation de cet appareil de chauffage AVERTISSEMENT testez toutes les conduites de gaz et les connexions pour détecter les fuites après l installation ou la révision N utilisezjamaisdeflammenuepour rechercher une fuite Appliquez une solutiondesavonliquideetd eausur touslesjoints Laprésencedebulles ...

Страница 17: ...es des dimensions de la rallonge électrique Jusqu à 15 m 50 pi employez un cordon de calibre 18 AWG Entre 16 et 30 m 51 et 100 pi employez un cordon de calibre 16 AWG Entre 31 et 60 m 101 et 200 pi employez un cordon de calibre 14 AWG 4 Branchez la rallonge électrique dans une prise de terre trifilaire de 120 volts et 60 hertz 5 Ouvrez lentement la vanne d approvisionnement en propane du ou des rés...

Страница 18: ...4 Faites inspecter l appareil de chauffage une fois l an par une entreprise de service qualifiée 5 Enlevezlesproduitscombustiblesetlescorpsétran gers qui se trouvent dans l appareil de chauffage 6 Nettoyez les pales de ventilateur chaque saison ou au besoin voir Ventilateur CALENDRIER D ENTRETIEN PRÉVENTIF Pièce Périodicité Comment Ventilateur Voir Ventilateur PROCÉDURES D ENTRETIEN AVERTISSEMENT n...

Страница 19: ...s au 1 905 826 8010 Lorsque vous appelez DESA Industries soyez prêt à fournir votre nom votre adresse le numéro du modèle de l appareil de chauffage une description de la panne de l appareil de chauffage la date de l achat En général nous vous demanderons de retourner la pièce à l usine PIÈCES QUI NE SONT PAS SOUS GARANTIE Communiquez avec un revendeur autorisé de ce produit S il ne peut vous four...

Страница 20: ...ent 2 Aucune étincelle à l allumeur Voir Allumeur page7 Sivouspercevez une étincelle sur l allumeur faites réparer l appareil de chauffage par un technicien qualifié Si vous ne percevez aucune étincelle A Le fil d allumage est desserré ou débranché B L espace ne permet pas d étin celles C L électrode d allumage est défectueuse 1 L approvisionnement en propane peut ne pas être adéquat 2 La températur...

Страница 21: ... On Off Switch Interrupteur de marche arrêt High Temp Switch Interrupteur pour haute température Thermostat White Blanc White Blanc White Blanc T Line Ligne Neutral Neutre Green or Green Yellow Vert ou vert jaune Green Vert Motor Moteur Blue Bleu Blue Bleu Blue Bleu Green Vert Black Noir Black Noir Black Noir White Blanc White Blanc White Blanc Orange Ignitor Allumeur Solenoid Valve Électrovanne A...

Страница 22: ...LÉE DES PIÈCES MODÈLES RCLP155AT 33 2 1 31 12 26 43 32 10 11 38 20 21 6 7 6 5 3 37 34 Note Screws are standard hardware items 28 7 15 17 27 8 14 36 29 39 4 8 13 25 23 16 42 30 20 35 22 24 18 19 41 44 45 9 40 46 47 Remarque Les vis sont de type ...

Страница 23: ...e de protection du ventilateur 1 34 101206 01 Prêt à monter du support du moteur et du relais 1 35 M11143 1 Bride de cordon 1 36 098219 17 Cordon électrique 1 37 M50631 Butoir en caoutchouc 2 38 NTC 4C Contre écrou 2 39 099157 01 Rivet de mandrin 3 16 po 1 40 099125 01 Bornier 1 41 M12461 25 Vis n 10 32 x 1 4 po 2 42 M10908 1 Vis hexagonale TPG F 6 32 x 0 25 2 43 M11271 8 Écrou à pince 8 44 101480...

Страница 24: ...ES DE COMMERCIALITÉ ET D ADÉQUATION À UN BESOIN PARTICULIER DESA Industries n assume aucune responsabilité pour des dommages indirects imprévus ou incidents Certains États ou provinces ne permettent pas l exclusion ou la restriction des dommages imprévus ou incidents et certaines restrictions ou exclusions pourraient ne pas s appliquer à votre cas Cette garantie limitée vous donne des droits spéci...

Отзывы: