598-1168-03

  Least Sensitive 

 Most Sensitive

The  sensor  is  less  sensitive  to  motion  directly 
towards  it  and  more  sensitive  to  motion  across 
coverage area.

Sensor

Motion

Motion

SPECIFICATIONS

Range ........................... Up to 30 ft. (9.1 m) 

[varies with surrounding 
temperature].

Sensing Angle .............. 360°
Electrical Load .............. Up to 100 Watt Maxi-

mum Incandescent (Up 
to 25 Watt Maximum 
each lampholder).

Bulb Type ...................... Candelabra Base, Type 

“B”, 25 Watt Maximum

Sensor Capacity ........... Up to 500 Watt (4.2 A.) 

Maximum

Power Requirements .... 120 VAC, 60 Hz
Operating Modes .......... TEST, AUTO, and 

MANUAL MODE

ON-Timer ...................... 1, 5, 10 minutes
DESA Specialty Products™ reserves the right to 
discontinue products and to change specifications at 
any time without incurring any obligation to incorpo-
rate new features in products previously sold.

Adjustment of Coverage Area

The  sensor  on  this  light  fixture  detects “motion” 
by the movement of heat (body heat) across the 
coverage area. However, following are examples 
of objects that also produce heat and can cause 
the sensor to false trigger:
• Pools of Water 

• Air Conditioners

• Dryer Vents 

• Fenced-In Animals

• Heating Vents 

• Automobile Traffic

If you suspect that a heat source of this type is falsely 
triggering the sensor and reducing the sensitivity 
does  not  solve  the  problem,  then  a  lens  shield 
(included) can be installed. The plastic lens shield 
is divided into 6 sections. Each section will reduce the 
coverage angle by 30 degrees. Also, the tip of each 
section may be removed to change the effective 
range of the sensor.

Area 
Blocked

1.  Break off the amount of lens shield needed to 

block the desired area of coverage.

2.  Cut desired amount of foam tape needed to 

adhere the lens shield to the sensor lens.

3.  Remove paper backing from one side of cut 

foam tape and adhere foam tape to inside of 
lens shield.

4.  Remove paper backing from other side of cut foam 

tape and adhere lens shield to sensor lens.

5.  Retest to confirm that the sensor is no longer 

false triggering.

Note:  To  help  determine  amount  of  lens  shield 
required, apply small sections one at a time. Ad-
ditional sections can be applied if necessary.

LO

 - M

 - HI

SE

NS

ITIVITY

ON-

TIM

E

TEST

  1 

 5  

10 

MIN

Lens Shield

Sensor 
Lens

Area 
Blocked

Lens 
Shield

Lens 
Shield

Portion 
Removed

Effective
Coverage Area 
(Top View)

Содержание Portfolio PF-4305

Страница 1: ...to calibrate resets to Auto Mode at dawn ON TIME Set the ON TIME switch on the sensor to TEST TEST 1 5 10 MIN TEST Set ON TIME switch to 1 5 or 10 minutes AUTO ON TIME Switch at 1 5 or 10 minutes back...

Страница 2: ...s from light xture cover 2 Remove cover from base 3 Removetwodecorativenutsfrom xturescrews in universal mounting bracket 4 Remove universal mounting bracket from base Decorative Nut Light Fixture Bas...

Страница 3: ...there is any question as to the suitability of the system When controlling an additional light xture s the maximum wattage of the motion sensor on this xture should be observed See illustration below...

Страница 4: ...ystem Itisrecommendedthat onlypeoplewithelectricalwiringexperienceattempt this con guration Please call our customer service number 1 800 858 8501 before attempting this wiring If the dual controlled...

Страница 5: ...ols of Water Air Conditioners Dryer Vents Fenced In Animals Heating Vents Automobile Traf c Ifyoususpectthataheatsourceofthistypeisfalsely triggering the sensor and reducing the sensitivity does not s...

Страница 6: ...urchase and Place of Purchase No Service Parts Available for this Product THREE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you speci c legal rights You may also have other rights whi...

Страница 7: ...UNCIONAMIENTO ON TIME Ponga el interruptor de ON TIME DURACI N del detector en TEST PRUEBA TEST 1 5 10 MIN PRUEBA Ponga el interruptor de tiempo ON TIME en la posici n de 1 5 10 minutos AUTOMATICO Mue...

Страница 8: ...ete a mano los dos tornillos del aparato 2 Sujete bien el soporte universal de montaje a la caja de empalme usando los dos tornillos provistos Tornillo del aparato apretado a mano Caja de empalme Sopo...

Страница 9: ...ladas en el aparato Tornillo de conexi n a tierra M todo recomendado de conexi n a tierra Una l mpara detectora de movimiento Dos l mparas detectoras de movimiento trabajan do independientemente Negro...

Страница 10: ...ontrol doble Serecomiendaques lopersonasconamplios conocimientos de electricidad conecten este tipo de con guraci n Porfavorcontactoconnuestrodepar tamentodeasistenciaalclienteanteshacerestetipo de co...

Страница 11: ...e la cinta espumosa cortada y adhiera la cubierta a la placa trasl cida del detector 5 Vuelva a probar para con rmar que el detector ya no presenta activaciones err neas Nota Para ayudar a determinar...

Страница 12: ...ales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Para reclamos por la garant a se requiere la prueba de compra SERVICIO T CNICO No enviar los prod...

Отзывы: