www.desatech.com
119169-01E
8
INSTALLATION ITEMS
Before installing heater, make sure you have
the items listed below.
• for propane/LP gas, external regulator
(supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment
trap
• tee
joint
• pipe
wrench
• for natural gas, test gauge connection*
• hardware
packet
- wall anchor (4)
095112-02
- red key (1)
095116-01
- pan head screw, black (4)
097403-02
- nylon spacer (2)
099064-02
- clamp (1)
099123-01
- Phillips head screw, silver (4) 100159-02
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable alter-
native to test gauge connection. The optional
CSA design-certified equipment shutoff valve
can be purchased from your dealer. See
Ac-
cessorie
s, page 26.
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
You can locate heater on floor, away from
a wall. An optional floor mounting stand is
included.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing or other flammable objects
are less than 36" from the front,
top or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
INSTALLATION
Continued
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT:
Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See
Air for Combustion and Ventila-
tion
, page 5. If high humidity is experienced,
a dehumidifier may be used to help lower the
water vapor content in the air.
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above floor
• locate heater where moving
vehicle will not hit it
For convenience and efficiency, install heater
• where there is easy access for operation,
inspection and service
• in coldest part of room
An optional fan kit is available from your dealer.
See
Accessories
, page 26. If planning to use
fan, locate heater near an electrical outlet.
Minimum
From
Sides Of
Heater
36"
2"
FLOOR
CEILING
Minimum
Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material
Left
Side
Right
Side
6"