OPTIONAL OUTSIDE AIR KIT 
(MODEL AK4)

The installation of an outside air kit should be 

completed during the rough framing of the fire-

place due to the nature of it's location. Outside 

combustion  air  is  accessed  through  a  vented 

crawl space.

  CAUTION:  Air  inlet  ducts 

must  not  be  terminated  in  an 

attic space.

Avoid installing outside air eyebrow in areas where 

inlet opening may be blocked by snow, bushes or 

other obstacles (see Figure 10).
The maximum height for the air inlet termination 

cannot exceed 3 feet below the B-vent termination 

exhaust height.

Figure 10 - Outside Air Kit

Secure to Collars with Duct Tape or 
Screws

Air Inlet 
Location 
Must Allow 
For Bushes 
or Snow

Vent Hood 
Required for 
Wall Installation

Air Inlet 
Eyebrow

Vented Crawl Space
(Check Local Codes 
Before Installing in a 
Vented Crawl Space)

MILLIVOLT MODELS (GL36PN/PNP)

The installation of a wall switch in this millivolt 

control appliance allows you to activate the gas 

control valve without the use of normal current.

  CAUTION:  Do  not  connect 

this millivolt system wall switch 

to a regular 120v power source! 

Gas valve will be damaged be-

yond repair. 

Wall Switch Installation

1.  Remove the J-box cover plate from side of 

applianceʼs outer surround.

2.  Using the 18 ga. millivolt wire and wall switch 

(both supplied), connect wiring per wiring 

diagram (see Figure 11). For more detail, see 

Wiring Diagrams

 on page 16.

Note:

 If any of the original 10 feet supplied wire 

must be replaced, use Thermostat Millivolt Wire 

18 AWG Type CL2-105 C or equivalent only.

IMPORTANT

: Do not hook up to standard 120 

VAC household wiring.

Figure 11 - Wall Switch Installation

O

F

P

IL

OT

ON

F

T

O

I

P L

7

TP

T

H

TP

TH

Wall Switch

(Supplied)

Back View

To Thermopile

Route Millivolt Wires 
(Supplied) Through 
Electrical Conduit Bushing

ELECTRONIC MODELS  
(GL36PNE/PNEP)

This appliance must be properly wired to standard 

120v household current through the DESA-pro-

vided wall switch before its remote control unit 

can be used to activate the automatic pilot ignition 

(turn fireplace flames ON).

Wall Switch Installation

1.  Remove the J-box cover plate from side of 

applianceʼs outer surround.

2.  Using the 18 ga. wires coming through strain 

relief grommet on side of applianceʼs outer 

wall to standard household 120 VAC current 

through the wall switch provided, as shown in 

Figure 12, page 9. For more detail, see 

Wiring 

Diagrams

, page 16.

Note:

 If any of the original 10 feet supplied wire 

must be replaced, use 20 AWG electrical wire or 

equivalent only.

Содержание Marblehead GL36PN

Страница 1: ...this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfroman...

Страница 2: ...to install and maintain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers...

Страница 3: ...y for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 2 Forpropane LP replace donotplacepropane LP supply tank s inside any structure...

Страница 4: ...way Provide adequate clearancesaroundairopeningsintothecombus tion chamber along with adequate accessibility clearance for servicing and proper operation SAFETY INFORMATION Continued 16 Do not instal...

Страница 5: ...approved for use in this gas appliance This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code AN...

Страница 6: ...lowing precautions must be observed 1 Do not connect this appliance to a chimney system used for a solid fuel burning re place 2 Install in an area providing ventilation and adequate combustion air 3...

Страница 7: ...N A6 B 1 type gas vent pipe is a double wall vent ing system not supplied which must be installed during rough framing of the appliance Any B 1 type gas vent system may be used for proper vent ing as...

Страница 8: ...yond repair Wall Switch Installation 1 Remove the J box cover plate from side of appliance s outer surround 2 Using the 18 ga millivolt wire and wall switch both supplied connect wiring per wiring di...

Страница 9: ...he information sticker attached to the unit when eld converting See Speci cations page 15 when derating The gas control valve is secured to the burner pan assembly underneath the front ledge A 1 8 NPT...

Страница 10: ...nstallation is completed Afterensuringthatthegasvalve is on apply a commercial leak detection solution to all con nections and joints If bubbles appear leaks can be detected and corrected Donotuseanop...

Страница 11: ...Facing Material Figure 18 Correct Pilot Flame Pattern Millivolt Assembly Figure 19 Correct Pilot Flame Pattern Electronic Assembly BURNER FLAME ADJUSTMENT The air shutter located at the base of the m...

Страница 12: ...FT your left as you face the replace moves glass door s top inner corner UP moving spring clip to the RIGHT moves glass door s top inner corner DOWN c When door alignment is satisfactory use Phillips...

Страница 13: ...ning logs will give off a paper burning smell Orange ame will also be pres ent Open window to vent smell This will only last a few hours 1 STOP Read the safety information column 1 2 Turn wall switch...

Страница 14: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a quali ed service tech nician or gas supplier Force or attempted repair may result...

Страница 15: ...g or brushing at least twice a year Take care not to alter the set tings on the pilot assembly Do not use abrasive liquids or cleaners for cleaning glass doors and trims Any household glass cleaner sh...

Страница 16: ...PPLY MILLIVOLT WIRING DIAGRAM STEP DOWN TRANSFORMER EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N C SW HEAT LIMIT SWITCH 120V AC 120V AC INCOMING OR BREAKER FUSE BOX OFF ON SUPPLIED WAL...

Страница 17: ...control valve 1 Wall switch wires defective 2 Thermopile or sensor not generating suf cient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Millivolt output on thermo pile too...

Страница 18: ...lt current is being sent back to regulator 2 If valve knob and wall switch are in the ON position prob able defective control valve 1 Wall switch wires defective 2 Thermocouple generator or sensor not...

Страница 19: ...22180 Wall Switch 14112 Cover Plate 14113 For use with all models IGNITION CONTROL 110286 01 For use with all models GAS VALVE CONVERSION KIT Millivolt Propane LP Gas PC GL36 Millivolt Natural Gas NC...

Страница 20: ...ali cations 1 The gas appliance must be installed as per the DESA installation instructions and local building codes The use of components manufactured by others with this DESAgas appliance except for...

Отзывы: