Desa Marblehead GL36PN Скачать руководство пользователя страница 4

www.desatech.com

55175-F

4

11.  Keep the area around your fireplace clear of 

combustible  materials,  gasoline  and  other 

flammable vapor and liquids. Do not run fire-

place where these are used or stored. Do not 

place items such as clothing or decorations on 

or around fireplace.

12.  Do not use this fireplace to cook food or burn 

paper or other objects.

13.  Do not use any solid fuels (wood, coal, paper, 

cardboard, etc.) in this fireplace. Use only the 

gas type indicated on fireplace nameplate.

14.  This appliance, when installed, must be electri-

cally grounded in accordance with local codes 

or, in the absence of local codes, with the 

National Electrical Code, ANSI/NFPA 70

 or 

the 

Canadian Electrical Code, CSA C22.1

.

15.  Do not obstruct the flow of combustion and 

ventilation air in any way. Provide adequate 

clearances around air openings into the combus-

tion chamber along with adequate accessibility 

clearance for servicing and proper operation.

SAFETY INFORMATION

Continued

16.  Do not install fireplace directly on carpeting, 

vinyl tile or any combustible material other 

than wood. The fireplace must set on a metal 

or wood panel extending the full width and 

depth of the fireplace.

17.  Do not use fireplace if any part has been ex-

posed to or under water. Immediately call a 

qualified service person to arrange for replace-

ment of the unit.

18.  Do not operate fireplace if any log is broken. 
19.  Do not use a blower insert, heat exchanger 

insert or other accessory not approved for use 

with this fireplace.

20.  Provide  adequate  clearances  around  air 

openings.

DIMENSIONS

SIDE VIEW

FRONT VIEW

TOP VIEW

1

/

2

"

12"

1

/

2

"

24"

40"

36 

1

/

2

"

8"

37 

1

/

2

"

1

/

4

"

40"

1

/

2

"

1

/

2

"

24"

BACK VIEW

16" 12"

1

/

4

"

1

/

2

"

9"

13"

1

/

2

"

20 

1

/

2

"

23"

19 

1

/

4

"

19 

3

/

8

"

20 

5

/

8

"

6"

24"

19 

1

/

4

"

4"

6" O.D.

16"

52 

1

/

2

"

Содержание Marblehead GL36PN

Страница 1: ...this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfroman...

Страница 2: ...to install and maintain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers...

Страница 3: ...y for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 2 Forpropane LP replace donotplacepropane LP supply tank s inside any structure...

Страница 4: ...way Provide adequate clearancesaroundairopeningsintothecombus tion chamber along with adequate accessibility clearance for servicing and proper operation SAFETY INFORMATION Continued 16 Do not instal...

Страница 5: ...approved for use in this gas appliance This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code AN...

Страница 6: ...lowing precautions must be observed 1 Do not connect this appliance to a chimney system used for a solid fuel burning re place 2 Install in an area providing ventilation and adequate combustion air 3...

Страница 7: ...N A6 B 1 type gas vent pipe is a double wall vent ing system not supplied which must be installed during rough framing of the appliance Any B 1 type gas vent system may be used for proper vent ing as...

Страница 8: ...yond repair Wall Switch Installation 1 Remove the J box cover plate from side of appliance s outer surround 2 Using the 18 ga millivolt wire and wall switch both supplied connect wiring per wiring di...

Страница 9: ...he information sticker attached to the unit when eld converting See Speci cations page 15 when derating The gas control valve is secured to the burner pan assembly underneath the front ledge A 1 8 NPT...

Страница 10: ...nstallation is completed Afterensuringthatthegasvalve is on apply a commercial leak detection solution to all con nections and joints If bubbles appear leaks can be detected and corrected Donotuseanop...

Страница 11: ...Facing Material Figure 18 Correct Pilot Flame Pattern Millivolt Assembly Figure 19 Correct Pilot Flame Pattern Electronic Assembly BURNER FLAME ADJUSTMENT The air shutter located at the base of the m...

Страница 12: ...FT your left as you face the replace moves glass door s top inner corner UP moving spring clip to the RIGHT moves glass door s top inner corner DOWN c When door alignment is satisfactory use Phillips...

Страница 13: ...ning logs will give off a paper burning smell Orange ame will also be pres ent Open window to vent smell This will only last a few hours 1 STOP Read the safety information column 1 2 Turn wall switch...

Страница 14: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a quali ed service tech nician or gas supplier Force or attempted repair may result...

Страница 15: ...g or brushing at least twice a year Take care not to alter the set tings on the pilot assembly Do not use abrasive liquids or cleaners for cleaning glass doors and trims Any household glass cleaner sh...

Страница 16: ...PPLY MILLIVOLT WIRING DIAGRAM STEP DOWN TRANSFORMER EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N C SW HEAT LIMIT SWITCH 120V AC 120V AC INCOMING OR BREAKER FUSE BOX OFF ON SUPPLIED WAL...

Страница 17: ...control valve 1 Wall switch wires defective 2 Thermopile or sensor not generating suf cient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Millivolt output on thermo pile too...

Страница 18: ...lt current is being sent back to regulator 2 If valve knob and wall switch are in the ON position prob able defective control valve 1 Wall switch wires defective 2 Thermocouple generator or sensor not...

Страница 19: ...22180 Wall Switch 14112 Cover Plate 14113 For use with all models IGNITION CONTROL 110286 01 For use with all models GAS VALVE CONVERSION KIT Millivolt Propane LP Gas PC GL36 Millivolt Natural Gas NC...

Страница 20: ...ali cations 1 The gas appliance must be installed as per the DESA installation instructions and local building codes The use of components manufactured by others with this DESAgas appliance except for...

Отзывы: