background image

www.desatech.com

121486-01F

17

INSTALLATION

Continued 

4.  Place right front log (log #4) on peg of log 

#3 and grate prongs as shown in Figure 
23, page 16.

5.  Place left crossover log (log #5) on pegs 

of log #2 and #3 (see Figure 24). Place 

Figure 24 - Placement of Crossover Logs 

(Logs #5, #6, and #7)

Log #5

Log #6

Log #7

Figure 25 - Control Cover Log (Log #8) 

Placement

Log #8

OPERATION

middle crossover log (log #6) on pegs of 
log #1 and #2 (see Figure 24). Place right 
crossover log (log #7) on pegs of log #2 
and #4 (see Figure 24).

6.  Slide  control  cover  log  (log  #8)  into 

place between front logs #3 and #4 (see 
Figure 25).

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 
pilot, follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the 

appliance area for gas. Be sure to smell 
next to the floor because some gas is 

heavier than air and will settle on the 

floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 
gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 
If the knob will not push in or turn by 
hand, don’t try to repair it, call a quali

-

fied service technician or gas supplier. 
Force or attempted repair may result in 
a fire or explosion.

D.  Do  not  use  this  appliance  if  any  part 

has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.

Содержание LDL3930NRB

Страница 1: ...ctrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Страница 2: ...ented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation s...

Страница 3: ...ings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert h...

Страница 4: ...nd Maintenance page 22 9 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder residue within burner b...

Страница 5: ...DS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteries or other sources to light heater Air For...

Страница 6: ...Z223 1 NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and a...

Страница 7: ...Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ce...

Страница 8: ...e is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted NOTICE Thisheater isintended for use as supplemental heat U...

Страница 9: ...ee Operation WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoin ing wall MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Side Wall 16 Ceil...

Страница 10: ...es you must operate heater with chimney flue damper open Go to Install ing Damper Clamp Accessory for Vented Operation page 11 Mantel Clearances In addition to meeting noncombustible mate rial clearan...

Страница 11: ...must be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material ForMassachusettsResidentsOnly Installation ofthisventedgaslogsetintheCommonwealt...

Страница 12: ...oved flexible gas hose to gas control fitting in heater see Figure 11 IMPORTANT Hold gas fitting with wrench when connecting flexible gas hose 2 Locate two masonry screws in hardware package 3 Place h...

Страница 13: ...must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not re duce incoming gas pressu...

Страница 14: ...tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 17 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turni...

Страница 15: ...as valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show...

Страница 16: ...ifically approved with this heater may result in property damage or personal injury CAUTION After installa tion and periodically thereafter check to ensure that no flame comes in contact with any log...

Страница 17: ...hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air an...

Страница 18: ...fter the pilot is lit 1 STOP Read the safety information on page 17 2 Make sure equipment shutoff valve is fully open 3 Remove control cover log see Figure 26 4 Set remote selector switch in the REMOT...

Страница 19: ...its will have a slight curve but flame should be blue and have no yellow or orange color Figure 28 Pilot Propane LP Ignitor Electrode Pilot Burner Figure 29 Pilot Natural Ignitor Electrode Pilot Burne...

Страница 20: ...in high position see Figure 32 A beep from the receiver confirms the command Push ON OFF button again and burners will turn off A beep from the receiver confirms the command Figure 32 Hand Held Remot...

Страница 21: ...re The control system will cycle the fireplace on or off to maintain se lected temperature Child Safety Lock Out This function lets you deactivate the remote control buttons It is active when the lock...

Страница 22: ...o Turn Off Gas to Appliance page 19 see Troubleshooting page 24 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color WARNING T...

Страница 23: ...y Air Inlet Holes Shape of Holes May Vary by Model Figure 40 Injector Holder On Outlet Burner Tube Figure 41 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to In stalling Logs page 16...

Страница 24: ...n in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubin...

Страница 25: ...l knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company...

Страница 26: ...r off when us ing furniture polish wax carpet cleaners or similar products 1 Refer to Air for Combustion and Ventilation require ments page 5 1 Properly locate logs see Installing Logs page 16 2 Elimi...

Страница 27: ...fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warn ing statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burne...

Страница 28: ...nt parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s cal...

Страница 29: ...onal rock is desired CLEANING KIT CCK For all models Your vent free gas appliance requires regular cleaning and maintenance to prevent performance problems This kit gives you the tools and instruction...

Страница 30: ...atech com 121486 01F 30 Parts Models LDL3930NRB and LDL3930PRB 11 28 2 3 25 18 5 19 10 7 7 6 4 20 24 16 14 26 9 23 23 15 16 8 23 23 23 23 17 22 28 29 21 1 12 13 27 1 27 2 27 3 27 4 27 5 27 6 27 7 27 8...

Страница 31: ...Extension 1 21 121129 01 Proflame Remote Control 1 22 121129 02 Proflame Receiver 1 23 M11084 26 Screw HWH AB 10 16 x 0 38 17 24 M12461 26 Screw Hex SLT WSR 10 32 x 0 38 6 25 098249 01 ODS Nut 2 26 1...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...