7

These models are tested and approved for use with DESA (direct-
vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and
can not be attached to a chimney or flue system serving a separate
solid fuel or gas burning appliance. A direct-vent appliance must have
its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through
an outside wall or vertically through a roof or chase enclosure using
the following guidelines:
• When venting system terminates horizontally on an outside wall,

you may install a standoff if the termination cap is to be in-
stalled directly on a combustible finish such as vinyl, wood,
stucco, etc.

• Never run the vent downward as this may cause excessive tem-

peratures which could cause a fire.

• Vent pipe air space clearances to combustibles are 1" on all sides

except on the horizontal sections, which requires 2" clearance
from the top of the pipe. Where the termination cap penetrates a
combustible wall, 1" air space clearance is required.

• Snorkel terminations are required when minimum clearance to grade

cannot be met (see Figure 16 on page 11).

• Have fireplace and selected vent components on hand to help

determine the exact measurements when elbowing or offsetting.
Always use wall firestops when penetrating walls and firestops
when penetrating ceilings or attic spaces.

• Install horizontal venting with a 1/4" rise for every 12" of run

toward the termination.

VENTING INSTALLATION
INSTRUCTIONS

NOTICE: Read these instructions completely be-
fore attempting installation.

 WARNING: Read all instructions completely and

thoroughly before attempting installation. Failure to
do so could result in serious injury, property damage
or loss of life.

NOTICE: Failure to follow these instructions will void
the warranty.

 WARNING: This gas fireplace and vent assembly

must be vented directly to the outside. The venting
system must NEVER be attached to a chimney serv-
ing a separate solid fuel burning appliance. Each
direct-vent gas appliance must use a separate vent
system. Do not use common vent systems.

 WARNING: Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the horizontal
sections, which require 2" clearances from the top of
the pipe. Where the termination cap penetrates a com-
bustible wall, 1" air space clearance is required.

VENTING INSTALLATION INSTRUCTIONS

Installation Precautions

INSTALLATION PRECAUTIONS

• Wear gloves and safety glasses for protection
• Use extreme caution when using ladders or when on roof tops
• Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting
system:
• Installation of any damaged venting component
• Unauthorized modification of the venting system (Do not cut

or alter vent components)

• Installation of any component part not manufactured or ap-

proved by DESA

• Installation other than as instructed by these instructions

IMPORTANT: 

Do not seal vent cap to pipe. Cap must be removable

for service.

Содержание K42EN Series

Страница 1: ...n service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a qualified in stall...

Страница 2: ...liance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s...

Страница 3: ...This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Ca nadian Electrical C...

Страница 4: ...he location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not lo...

Страница 5: ...s tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do not in...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...ng ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore at...

Страница 8: ...ctions together and twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall...

Страница 9: ...sition the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exterior fas...

Страница 10: ...igure includes a chart with critical minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figur...

Страница 11: ...throughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requir...

Страница 12: ...max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max 45 Elbow Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace Figu...

Страница 13: ...oom install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are f...

Страница 14: ...wo90 Elbows Vertical Round High Wind Termination Shown VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination Cont Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5...

Страница 15: ...Wall Pipe Galvanized PA58 712 Adjustable7 12 SectionDoubleWallPipe Galvanized FPA58 6 6 DuraventCollartoFMIPipeAdaptor 6 Collar Pipe Section DPA58 6 6 FMICollartoPipeDuraventAdaptor 6 Collar Pipe Sec...

Страница 16: ...ructions provided in the blower accessory kit 1 Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the bl...

Страница 17: ...e thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in order to sense temperature and properly operate The blower will be held in position against the back wall by the magnet...

Страница 18: ...External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator Vent Pointing Down FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Installing Optional Blow...

Страница 19: ...provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas supply to contro...

Страница 20: ...ection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fireplace pages 24 and 25 Check all other internal joints for leaks 6 Turn off fireplac...

Страница 21: ...tch Cleaning Glass Door See Cleaning and Maintenance on page 26 Figure 38 Installing Rear Left and Right Brick Panels Rear Brick Panel INSTALLING BRICK LINER MODELS BL42DA SA BL42DHA SA WARNING If fir...

Страница 22: ...ber Material Figure 44 Placing Ember Material on Burner 8 9 Figure 43 Installing Logs No 8 and No 9 WARNING The glass door must be securely in place before running this fireplace Do not run this firep...

Страница 23: ...ttery by removing the insulat ing tab on the back of the handset see Figure 46 The battery is included pre installed 4 Once the battery is activated the unit is ready to use 5 Close lower louver panel...

Страница 24: ...ars at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay lit after s...

Страница 25: ...ove any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit an...

Страница 26: ...ed CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotoperatefire...

Страница 27: ...e and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace contro...

Страница 28: ...erial OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position Gas o...

Страница 29: ...CAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehaveyourmodeland serial n...

Страница 30: ...rmation visit www desatech com 30 ILLUSTRATED PARTS BREAKDOWN Models V K42EN V K42ENH V K42EP V K42EPH ILLUSTRATED PARTS BREAKDOWN MODELS V K42EN V K42ENH V K42EP V K42EPH 6 7 20 17 18 13 2 12 19 8 1...

Страница 31: ...4 108331 01 Top Louver Assembly 1 5 108331 02 BottomLouver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 02 Heat Shield 1 10 111925 01 Log Set 1 10 1 11193...

Страница 32: ...visit www desatech com 32 ILLUSTRATED PARTS BREAKDOWN Models V K42EN V K42ENH V K42EP V K42EPH ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V K42EN V K42ENH V K42EP V K42EPH 7 9 8 12 12 6 1...

Страница 33: ...02 Screw 8 32 x 3 8 PPH Zinc 2 8 108866 01 Pilot Natural Gas 1 108866 02 Pilot Propane LP Gas 1 9 111316 01 Pilot Bracket 1 10 111913 02 Burner Base Gasket 1 11 111310 02 Firebox Bottom 1 12 11165 Scr...

Страница 34: ...s FPD42P Filligree Panel Kit Platinum FPD42PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT42B Rolled Louver Trim Kit Brushed Brass LT42P Rolled Louver Trim Kit P...

Страница 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 36: ...111922 01C For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Страница 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: