background image

www.desatech.com

113084-01J

14

INSTALLATION

Continued

PRESSURE TESTING HEATER GAS 
cONNEcTIONS

1.  Open equipment shutoff valve (see Figure 

17, page 13).

2.  Open main gas valve located on or near 

gas  meter  for  natural  gas  or  open  pro-
pane/LP supply tank valve.

3.  Make sure control knob of heater is in the 

OFF position.

Figure 18 - Checking Gas Joints 

(Oxford™ Stove Model Shown)

Control Valve Location

Propane/LP 
Supply Tank

Equipment Shutoff Valve

Figure 19 - Checking Gas Joints 

(Oxford™ Stove Model Shown)

Gas Meter

Equipment 
Shutoff Valve

Control Valve Location

OPERATION

4.  Check  all  joints  from  equipment  shutoff 

valve to control valve (see Figure 18 or 
19). Apply a noncorrosive leak detection 

fluid to gas joints. Bubbles forming show 

a leak.

5.  Correct all leaks at once.
6.  Light  heater  (see 

Operation

).  Check  all 

other internal joints for leaks.

7.  Turn off heater (see 

To Turn Off Gas to 

Appliance

, page 15).

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the pi

-

lot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 
gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 
If the knob will not push in or turn by 
hand, don’t try to repair it, call a quali

-

fied service technician or gas supplier. 
Force or attempted repair may result in 
a fire or explosion.

D.  Do  not  use  this  appliance  if  any  part 

has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.

LIGHTING 

INSTRUcTIONS

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Open window to vent smell. This 

will only last a few hours.

1.  STOP!  Read  the  safety  information 

above.

2.  Make sure equipment shutoff valve is fully 

open.

Содержание GXSVYD18NRA

Страница 1: ...do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Страница 2: ...not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sa...

Страница 3: ...mfurniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater SAFETY Continued Stove becomes very hot when running heater Ke...

Страница 4: ...SAFETY Continued 11 Do not run heater where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this stove to cook food or burn paper or other objects 13 Do not use hea...

Страница 5: ...system re quires no matches batteries or other sources to light heater WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by...

Страница 6: ...ed a part of the un confined space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING...

Страница 7: ...ing to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figur...

Страница 8: ...st point of stove top to any combustible side wall should not be less than 12 B Clearances from outermost point of stove top to any combustible back wall should not be less than 6 includes corner inst...

Страница 9: ...Legs include leg leveler bolts 1 Bottom door 3 Top grates 1 Hardware kit bag with fasteners 5 Carefully lay stove body on back to attach bottom components to stove body see Figure 5 Rest stove on drop...

Страница 10: ...s 13 Remove gas log heater from carton Note Do not pick up gas log heater by the burner itself This could damage heater Always handle the gas log heater by the heater base only 14 Fasten stove pan to...

Страница 11: ...x 1 bolts and washers 6 Place freestanding stove in desired posi tion in room Be sure to maintain clear ances to combustibles as outlined on page 8 CAUTION After installa tion and periodically thereaf...

Страница 12: ...ally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of volume will oc...

Страница 13: ...sures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig wi...

Страница 14: ...t which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some...

Страница 15: ...nob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas supplier for repairs...

Страница 16: ...l burner turns on Hold the control button again until burner turns off see Figure 23 To Lock press both buttons on hand held remote control until light stops flashing Hand held remote control is now l...

Страница 17: ...y debris or rust with no flame present If so turn off heater and let cool Remove blockage Blocked burner flame holes will create soot Pilot Burner Figure 25 Correct Pilot Flame Pattern Propane LP Show...

Страница 18: ...airpassagewaysofheater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent clean ing due to excessive lint from...

Страница 19: ...essure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if p...

Страница 20: ...Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas contro...

Страница 21: ...lot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page REM...

Страница 22: ...www desatech com 113084 01J 22 Parts Models SVYD18PRA and svyd18nrA 17 17 18 19 24 15 14 16 13 12 12 11 22 23 20 10 9 21 4 8 5 3 2 21 7 6 1...

Страница 23: ...e 1 099387 15 Pilot Tube 1 10 103781 02 Gas Control Valve 1 103781 01 Gas Control Valve 1 11 103345 02 Lower Bracket 1 12 M11084 38 Screw 8 x 0 38 7 13 Painted Base Assembly 1 14 098271 10 Ignitor Cab...

Страница 24: ...m 113084 01J 24 2 5 5 5 5 8 7 4 6 7 1 7 2 4 9 7 3 3 1R 1C 1L 10 9 10 Parts Oxford VCIS Series and PVCIS Series Victor Hearth VH A Series Indicates Color Suffix Designation Oxford Stove Body Victor Hea...

Страница 25: ...uts 1 Per Unit 1 7 3 Bottom Floor Bolts M6 x 1 25 mm Long With Flat Washer And Lock Washer 4 Per Unit 1 7 4 Leg Bolts M8 x 1 25 20 mm Long With Flat Washer And Lock Washer 4 Per Unit 1 8 104178 01 Bac...

Страница 26: ...ting LLC have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under...

Страница 27: ...log heater to be turned on and off with a wall switch Cleaning Kit Cck For all models Your vent free gas appliance requires regular cleaning and maintenance to prevent performance problems This kit gi...

Страница 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: