ventilation Air From Outdoors

Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma

-

nent  openings:  one  within  12"  (30.5  cm)

  of 

the  ceiling  and  one  within  12"  (30.5  cm)

  of 

the floor. Connect these items directly to the 
outdoors  or  spaces  open  to  the  outdoors. 
These  spaces  include  attics  and  crawl 
spaces. Follow the 

National Fuel Gas Code, 

ANSI  Z223.1/NFPA  54,  Section  5.3, Air  for 
Combustion and Ventilation

 for required size 

of ventilation grills or ducts.

IMPORTANT:

  Do  not  provide  openings  for 

inlet or outlet air into attic if attic has a thermo

-

stat-controlled power vent. Heated air entering 
the attic will activate the power vent.

AIR FOR COMbUSTION 

AND VENTILATION

Continued

Figure 2 - Ventilation Air from Inside 

Building

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE:  This  heater  is  intended 

for use as supplemental heat. Use 

this heater along with your primary 

heating system. Do not install this 

heater as your primary heat source. 

If you have a central heating system, 

you may run system’s circulating 

blower while using heater. This will 

help circulate the heat throughout 

the house. In the event of a power 

outage, you can use this heater as 

your primary heat source.

  WARNING: A  qualified  ser-

vice person must install heater. 

Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 
correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 
type heater.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat-

ing plate. Field conversion is not 

permitted.

INSTALLATION ITEMS

Before installing heater, make sure you have 
the items listed below.
•  for  propane/LP  gas,  external  regulator 

(supplied by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  ground joint union

•  sediment trap
•  tee joint

•  pipe wrench
•  for natural gas, test gauge connection*
*  A CSA design-certified equipment shutoff 
valve with 1/8" NPT tap is an acceptable alter

-

native to test gauge connection. The optional 
CSA design-certified equipment shutoff valve 
can be purchased from your dealer. See 

Ac-

cessories

, page 26.

Or  

Remove  

Door into  

Adjoining  

Room,  

Option 3 

Ventilation Grills  

Into Adjoining Room, 

Option 2 

12" 

12" 

Ventilation

Grills into

Adjoining

Room, 

Option 1

Outlet

Air

Ventilated

Attic 

Outlet

Air

Inlet

Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Содержание GWRn18A

Страница 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and s...

Страница 2: ...ncer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of car bon mon...

Страница 3: ... not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 This heater shall not be installed in a bedroom or bathroom 4 If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Страница 4: ...al gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts Unpacking 1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly r...

Страница 5: ...e air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec ...

Страница 6: ...n support ________ Btu Hr actual amount used Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr used AIR FOR COMBUSTION AND VENTILATION Continued The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can sup port You must provide additional fresh air Your options are as follows A Rework wor...

Страница 7: ... the event of a power outage you can use this heater as your primary heat source WARNING A qualified ser vice person must install heater Follow all local codes CHECK GAS TYPE Use only the correct type of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater WARNING This appliance is equipped for eit...

Страница 8: ...nd joining wall You can locate heater on floor away from a wall An optional floor mounting stand is need ed Purchase the floor mounting stand from your dealer See Accessories page 26 WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 91 5 cm from the front top or sides of the heater as a ...

Страница 9: ...6 cm Min 16 40 6 cm Min 14 35 6 cm 12 30 4 cm Min Adjoining Wall 14 35 6 cm Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Only Insert Mounti Screws Through L Hole On Each En Floor Floor Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 14 35 6 cm apart from their cen ters Attach...

Страница 10: ...Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 2 5 cm deep 2 Fold wall anchor as shown in Figure 9 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For thin walls 1 2 1 3 cm or less insert red key ...

Страница 11: ...odes Use pipe of large enough diameter to allow proper gas volume to heater If pipe is too small undue loss of volume will occur Typical Inlet Pipe Diameters 16 18 000 Btu hr models 3 8 or greater 26 30 000 Btu hr models 1 2 or greater Installation must include equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from hea...

Страница 12: ...luid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION For propane LP gas make sure external regula tor has been installed between propane LP supply and heater See guidelines under Connect ing to Gas Supply page 11 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and e...

Страница 13: ... LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to thermostat gas valve see Figure 17 or 18 Apply a noncorrosive leak de tection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas...

Страница 14: ...o the PI LOT position Keep control knob pressed in for five 5 seconds 7 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attached to the front of burner Note You may be running this heater for the first time after hooking up to gas supply If so you may need to press in control knob for 30 seconds or more This will allow air to bleed from the gas ...

Страница 15: ...urner Only pilot stays lit Turn control knob clockwise to the PILOT position THERMOSTAT Control OPERATION The thermostatic control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will ...

Страница 16: ... Figure 27 shows an incorrect burner flame pattern If burner flame pattern is incorrect as shown in Figure 27 turn heater off see To Turn Off Gas to Ap pliance page 15 see Troubleshooting page 18 Thermocouple Pilot Burner Pilot Burner Thermocouple Blue Flame Yellow Flame Figure 24 Correct Pilot Flame Pattern Figure 25 Incorrect Pilot Flame Pattern Figure 26 Correct Burner Flame Pattern Figure 27 I...

Страница 17: ...es a clean burning flame Keep these holes clear of dust dirt and lint Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To ...

Страница 18: ...or setting is not correct 1 Not enough combustion ventilation air REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace ignitor 7 Tighten nut holding piezo ignitor Nut is located inside heater cabinet at top 1 Turn on gas supply or open equipment shutoff valv...

Страница 19: ...valve 4 Hand tighten until snug then tighten 1 4 turn more 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 16 or replace ODS pilot assembly 6 Replace pilot assembly 7 Replace control valve 8 Wait one minute for safety interlock system to reset Repeat ignition operation 1 Clean burner orifice s see Cleaning and Maintenance page 16 or replace b...

Страница 20: ...ate and correct all leaks see Checking Gas Con nections page 12 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections page 12 1 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 2 Observe minimum installa tion clearances see Figure 4 page 8 3 Clean burner se...

Страница 21: ...er Weight 29 lb 13 2 kg Average Shipping Weight 33 lb 15 kg GWRP16A and GWRP16TA Propane LP Gas 16 000 Btu hr GWRP16 is variable Piezo Ignition Pressure Regulator Setting 8 W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 Average Heater Weight 22 lb 10 kg Average Shipping Weight 25 5 lb 11 6 kg GWRP26A and GWRP26TA Propane LP Gas 26 000 Btu hr GWRP26 is variable Piezo Ignition Pressure Reg...

Страница 22: ...esatech com 119346 01B 22 Illustrated Parts Breakdown Cabinet body Models GWRP16A GWRn18A GWRP26A GWRN30A GWRP16TA GWRn18TA GWRP26TA and GWRn30TA 14 15 8 5 6 7 4 3 1 2 16 10 9 11 12 13 17 See pages 24 and 25 ...

Страница 23: ...5 01 Roll Pin 1 11 098354 03 Control Knob 1 12 099415 18 Gas Regulator Propane LP Gas 1 099415 19 Gas Regulator Natural Gas 1 13 104819 02 Regulator Bracket 1 14 098522 24 Thermostat Gas Valve 1 15 102394 02 Thermostat Valve Mounting Bracket 1 16 107660 01 Inlet Tube 1 107660 03 Inlet Tube 1 103256 02 Inlet Tube 1 17 118721 04 Baffle 1 118721 03 Baffle 1 PARTS AVAILABLE NOT SHOWN 100642 03 Hardwar...

Страница 24: ...er Nut 1 7 099056 24 Injector Plaque A or C 1 2 099056 25 Injector Plaque A or C 1 2 8 099056 01 Injector Plaque B 1 099056 02 Injector Plaque B 1 9 103844 01 Control Valve 1 100747 01 Control Valve 1 10 103352 03 Tubing Valve to Plaque 1 103353 04 Tubing Valve to Plaque 1 11 103352 04 Tubing Valve to Plaque 1 103353 05 Tubing Valve to Plaque 1 12 103353 06 Tubing Valve to Plaque 1 If replacing OD...

Страница 25: ...njector Plaque B 1 099056 02 Injector Plaque B 1 If replacing ODS pilot and your model is pre 2002 your part number will be 099059 07 for natural gas models 103894 04 for propane LP models The thermocouple part number will be 098514 01 for both gases The electrode part number will be 098594 01 for both gases Burner Assembly GWRP26TA and GWRN30TA ILLUSTRATED PARTS BREAKDOWN and PARTS LIST Burner As...

Страница 26: ...placement Parts Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Technical Ser vice Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and s...

Страница 27: ... dealers of this product and or DESA Heating Products who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wea...

Отзывы: