13
105568
OWNER’S MANUAL
OPERATING
HEATER
Continued
CAUTION: Do not try to ad-
just heating levels by using the
manual shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.
Slightly press in control knob and
turn clockwise
to the
PILOT/IGN position.
2.
Fully press in control knob and turn
clockwise
to the OFF posi-
tion.
3.
Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
Slightly press in control knob and turn
clockwise
to the PILOT position.
1.
Remove front panel (see Figure 6,
page 8).
2.
Follow steps 1 through 5 under Light-
ing Instructions, page 12.
3.
With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
5.
Replace front panel.
MANUAL LIGHTING
PROCEDURE
Figure 17 - Control Knob In The OFF
Position
Figure 18 - Pilot
7.
Press in control knob and turn back
to PILOT/IGN. This should cause
the piezo ignitor to spark and light
the pilot gas. If needed, repeat steps
5 through 7 until pilot lights.
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 15
through 17. Also contact a qualified
service person or gas supplier for
repairs. Until repairs are made, light
pilot with match. To light pilot with
match, see Manual Lighting Proce-
dure.
8.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
9.
To light burner, slightly press in con-
trol knob and turn counterclockwise
. Release downward pres-
sure on control knob while turning.
Set control knob to desired heating
position.
Note:
Both HIGH, MED, and LOW
are locked positions. You must press
in control knob before turning it
from these positions.
Thermocouple
Ignitor Electrode
Pilot Burner