background image

108319-01B

10

For more information, visit www.desatech.com

For more information, visit www.desatech.com

NOTICE: Shut off gas supply and disconnect heater
from gas supply. Contact a qualified service person
to do this.

IMPORTANT

: For clarity, gas valve assembly and grate/burner

assembly are not shown in Figures 24 and 25. They will, however,
be in your fireplace when you are installing the blower. Also for
clarity the firebox is shown with dotted lines.

1.

Open lower louver panel as shown in Figure 24.

2.

Attach the power cord to the blower motor by firmly pushing
the two female terminals at the end of the power cord onto the
two spade terminals on the blower motor.

3.

Attach green ground wire from power cord to blower housing
using screw provided (see Figure 24). Tighten screw securely.

4.

Place the blower under the firebox and against the lower rear
wall of firebox outer wrapper with the exhaust port directed
upward. Align the holes in the top mounting tabs of blower
with holes in wall of wrapper (see Figure 24). Using the two
screws provided, mount blower and tighten screws securely.

5.

Be sure all wire terminals on blower are attached securely.
Make sure the screw retaining the green wire is tight.

6.

Remove screws securing the plate containing the ON/OFF
switch to the bottom of the firebox and set aside.

7.

Place speed control against the back of this plate and push the
plastic control shaft through opening (see Figure 25).

8.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise un-
til tight against the plate. Place control knob (provided) onto
shaft (see Figure 25).

9.

Replace plate containing switches and tighten screws securely.

10. Plug in blower power cord.

a. If your fireplace system is installed as a freestanding unit

with an accessory mantel, determine whether the power cord
will exit the left side or the right side of the firebox. Install
one plastic bushing (provided) into the 1 

1

/

2

" hole in the outer

casing through which the power cord will exit. Install the sec-
ond plastic bushing (provided) into the floor support bracket
if exiting through the right side (see Figure 26, page 11). Route
power cord through (both) plastic bushing(s) and plug the
power cord into a properly grounded 3-prong wall receptacle
near the firebox.

INSTALLING BLOWER
ACCESSORY IN DIRECT-VENT
FIREPLACE SERIES BHDV,
(E)BDV, DDV, HDV, CDV, CHDV,
DVF(E), OR DVFH

IMPORTANT: Read all installation instructions be-
fore installing blower.

b. If your fireplace system installation is recessed and/or

pre-wired, a qualified installer must make all electrical con-
nections for the outlet kit included with the fireplace.

11. Check to make sure that the power cord is completely clear of the

blower wheel and that there are no other foreign objects in blower
wheel. Turn blower on and check for operation. Turn blower off
by rotating knob fully counterclockwise before continuing.

Figure 24 - Mounting Blower to Firebox

Lower Rear
Wall of
Firebox
Wrapper

Lower Louver
Panel

Screw

Exhaust Port

Blower Assembly

Green
Ground Wire

Screws

Figure 25 - Attaching Speed Control to Firebox

Speed Control

Control Shaft

Locknut

Control
Knob

Switch
Plate

 CAUTION: Never touch the blower wheel while in

operation.

INSTALLING BLOWER ACCESSORY IN DIRECT-VENT FIREPLACE SERIES
   BHDV, (E)BDV, DDV, HDV, CDV, CHDV, DVF(E), OR DVFH

Содержание Ga3750a

Страница 1: ...r specific applications and additional instructions WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle For Use With Fireboxes NL FB32C NL FB36C FB42C NL UV32C CGFB32C and CGFB36C Series Vent Free Fireplaces VSGF28 VYGF33 VTGF33 ...

Страница 2: ...ground wire is tight 6 Locate the plastic hole plug installed in the 3 8 diameter open ing in the lower right side of the firebox front panel see Fig ure 2 Remove the plastic plug and discard 7 Place speed control against inner wall of front panel pushing the plastic control shaft forward through the opening see Figure 3 Figure 1 Removing Screws from Firebox Bottom 8 While supporting speed control...

Страница 3: ... concrete firebrick floor from the firebox see Figure 5 Some model fireboxes require that you remove the side and rear panels first Follow the directions below to remove the side and rear fire brick panels for those fireboxes a Using a Phillips screwdriver remove the screw and retainer bracket at the top of the brick liner panel on the left side Care fully remove the left panel from the firebox se...

Страница 4: ...st front panel Place control knob provided on shaft see Figure 11 10 Turn on power to duplex outlet if previously turned off per the warning in column 2 page 3 11 Plug in blower power cord a If your firebox is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install 1 plas tic bushing provided into t...

Страница 5: ...ght your gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the firebox and remove any dust dirt or other obstructions INSTALLING BLOWER ACCESSORY IN MODEL SVFBC FREESTANDING STOVE NOTICE Shutoffgasheaterduringthefollow...

Страница 6: ...touch the blower wheel while in operation Figure 16 Attaching Blower to Mounting Bracket Blower Mounting Bracket Screws Exhaust Port Ground Wire OPERATING THE BLOWER Lightyourgasappliancewiththebloweroff Afterabout15minutes turn theblowerontodeliverheatedairatthetoplouvers Theblowerfeatures a variable control which allows you to select the speed you desire INSTALLING BLOWER ACCESSORY IN 32 FIREPLA...

Страница 7: ... an outlet is not installed in your fireplace you must install the GA3555 Outlet kit with cover in your fireplace which will sup ply a convenient 3 prong grounded electrical outlet for your blower Refertotheinstallationmanualprovidedwiththemodel GA3555 accessory for instructions on wiring the duplex outlet Note Aqualifiedinstallermustmakeallelectricalconnections CAUTION Never touch the blower whee...

Страница 8: ...gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the fire box and remove any dust dirt or other obstructions NOTICE Shut off gas supply and disconnect heater from gas supply Contact a qualified service person to do th...

Страница 9: ...lower Assembly Green Ground Wire CAUTION Never touch the blower wheel while in operation WARNING Failure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes INSTALLING BLOWER ACCESSORY IN FREESTA...

Страница 10: ...t against the plate Place control knob provided onto shaft see Figure 25 9 Replace plate containing switches and tighten screws securely 10 Plug in blower power cord a If your fireplace system is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install one plastic bushing provided into the 1 1 2 hole...

Страница 11: ...ure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury 13 Connect or reconnect gas supply following instructions given in the owner s manual supplied with your fireplace WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes Figure 26 Installing Pla...

Страница 12: ...n visit www desatech com For more information visit www desatech com 108319 01 REV B 09 03 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Technical Service Department 1 866 672 6040 www desatech com 108319 01 NOT A UPC ...