background image

For more information, visit www.desatech.com

 WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

—  Do  not  store  or  use  gasoline  or  other   flammable 

vapors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

UNVENTED (VENT-FREE) GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

24" THERMOSTAT MODELS

CSG3924NTA AND CSG3924PTA

Содержание CSG3924NTA

Страница 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your...

Страница 2: ...or these installations in accordance with ANSI Z21 11 2 Exception Do not install this appliance in a factory built fireplace that includes instructions stating it has not been test ed or should not be...

Страница 3: ...However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and p...

Страница 4: ...k of less than 100 lb capacity 18 Provide adequate clearances around air openings You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heat...

Страница 5: ...he Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas pro...

Страница 6: ...home needs to breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning applianc...

Страница 7: ...etermine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi mum Btu Hr the space can support Example 2 560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can supp...

Страница 8: ...an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You...

Страница 9: ...eated Adirtychimneyfluemay createanddistributesootwithin the house Inspect chimney flue and firebox for damage If dam aged repair flue before operat ing heater WARNING Seal any fresh air vents or ash...

Страница 10: ...tinued Note When installing your gas logs into a manufactured firebox follow firebox manufacturer s instructions for minimum clearances to combustible materials B Clearances from top of fireplace open...

Страница 11: ...al Slate Marble Tile etc Above Fireplace Figure 6 Minimum Mantel Clearances Without Using Hood Minimum Noncombustible Material Minimum Noncombustible Material Height Distances to Underside of Mantel T...

Страница 12: ...t meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between man tel shelf and top of fireplace opening a hood is not required see...

Страница 13: ...r base and logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through one hole on each side of the mounting bracket see Figure 1...

Страница 14: ...gas is commonly known as wellhead gas Installation Items Needed Before installing heater make sure you have the items listed below external regulator supplied by installer piping check local codes se...

Страница 15: ...ing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping Pre...

Страница 16: ...tion INSTALLING LOGS WARNING Failure to posi tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or perso...

Страница 17: ...n log 1 ember bed and rest back of log 6 on back log 4 see Figure 20 Figure 18 Installing Log 2 Right and Log 3 Left Figure 19 Installing Log 4 Figure 20 Installing Log 5 Right and Log 6 Left Log 5 Lo...

Страница 18: ...Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information in column 1 If you don t smell gas go to the next step Operation FOR YOUR SAFETY READ BEFORE LIGHTI...

Страница 19: ...tor Electrode Figure 24 Pilot Natural Ignitor Electrode Pilot Burner Thermocouple Thermocouple 9 To light the rear yellow flame burner push in and turn rear burner control knob coun terclockwise to th...

Страница 20: ...r flame pat ternsshowyellowtipping follow instructionsbelow Yellowflame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt orotherfineparticlesareburned by heater ca...

Страница 21: ...ted at the end of burner tubes again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holders 6...

Страница 22: ...en in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM Whenignitorbuttonispressed there is no spark at ODS pilot Whenignito...

Страница 23: ...qualified service person 1 Contact local natural or propane LP gas company 2 Clean burner s see Clean ing and Maintenance page 20 or replace burner orifice s 3 Contact qualified service person 1 Clea...

Страница 24: ...removed from line Have gas line checked by local natural or propane LP gas company 3 Observeminimuminstallation clearances see page 8 4 Clean burners see Clean ing and Maintenance page 20 1 Turn heat...

Страница 25: ...Locate and correct all leaks see Checking Gas Con nections page 16 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Mainte...

Страница 26: ...he mounting bracket This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications For positioning the thermostat sensing bulb elsewhere an...

Страница 27: ...Piezo Manifold Pressure 3 W C Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 5 W C Shipping Weight 30 lbs Certified Standards Z21 11 2 2000 For purpose of input adjustment Parts Log Models C...

Страница 28: ...www desatech com 123551 01D 28 PARTS Thermostat Controlled Models CSG3924NTA AND CSG3924PTA 1 16 17 2 18 12 28 24 27 27 27 27 27 27 8 8 7 9 13 5 6 19 20 4 14 10 25 3 26 22 15 21 11 23...

Страница 29: ...097159 04 Piezo Ignitor 1 15 098271 10 Ignitor Cable 1 16 099056 18 Burner Orifice Injector Back 1 099056 21 Burner Orifice Injector Back 1 17 101004 02 Burner Orifice Injector Front 1 101004 18 Burn...

Страница 30: ...r was malfunctioning purchase date Service Hints When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat for propane LP units...

Страница 31: ...__ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: