VENT-FREE PROPANE/LP GAS STOVE HEATER

TROUBLESHOOTING

 WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

 CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct
7. Depleted gas supply

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace piezo ignitor
6. Replace piezo ignitor

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 15) or replace ODS/
pilot assembly

6. Replace gas control
7. Contact local propane/LP gas company

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open equipment shutoff valve
4. A) Contact local propane/LP gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance, 
page 15) or replace ODS/
pilot assembly

5. Hand tighten until snug, then tighten

1/4 turn more

6. Replace thermocouple
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

Note:

 For additional help, visit DESA

International’s Technical Service web
site at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

www.desatech.com

Содержание Comfort Glow SL30PT

Страница 1: ...operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from...

Страница 2: ...ng could occur due to log curing and heater burning manufactur ing residues 9 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 15 10 Before using furniture pol...

Страница 3: ...There is no heat loss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas prohibit the use...

Страница 4: ...ating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to ar...

Страница 5: ...ot include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr u...

Страница 6: ...ir from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide t...

Страница 7: ...d adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must maintain minimum wall and ceiling clearan...

Страница 8: ...t to leg Thread bolt in tapped holes on stove body see Figure 8 and Figure 9 page 9 Figure 7 Removing Pallet Wood From The Bottom of The Stove Figure 8 Locating Threaded Holes for Stove Bottom Legs an...

Страница 9: ...ot holes and into threaded hole in stove body see Fig ure 11 Use an adjustable wrench or a 12mm socket to fasten step bolt Tighten step bolt until snug Make sure door moves freely 11 Install door catc...

Страница 10: ...t through heater base mounting hole and through stove bot tom Connect hex nut to bolt on under side of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sock...

Страница 11: ...quip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connec tion Purchase the optional CSA AGA de sign certifiedequipmentshutoffvalvefrom your dealer See Accessories pag...

Страница 12: ...nob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 21 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5...

Страница 13: ...n 1 If you don t smell gas go to the next step 5 Turn control knob counterclockwise C clockwise to the PILOT position Press in control knob for five 5 sec onds see Figure 22 Note You may be running th...

Страница 14: ...ESA International s technical service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specifi...

Страница 15: ...rner tube and pilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry...

Страница 16: ...aged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pi...

Страница 17: ...oved from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 15 or replace burner orifi...

Страница 18: ...e just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This i...

Страница 19: ...Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com Ea...

Страница 20: ...20 104464 VENT FREE PROPANE LP GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN SL30PT 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13...

Страница 21: ...80 01 Burner 1 11 101329 22 Control Valve 1 12 104472 01 Bracket 1 13 099211 01 Screw 2 14 102445 01 Piezo Ignitor 1 15 099387 13 Pilot Tube 1 16 098271 07 Ignitor Cable 1 17 104286 01 ODS Pilot LP 1...

Страница 22: ...22 104464 VENT FREE PROPANE LP GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN CISC CISG 7 4 6 4 5 4 5 1 5 2 3 5 3 5 4 2 1R 1C 1L...

Страница 23: ...1 Hardware Kit 1 5 1 Door Hinge Step Bolt With Shoulder 1 Per Unit 1 5 2 Door Catch Bolt M8 x 1 25 55mm Long With Two M8 Hex Nuts 1 Per Unit 1 5 3 Bottom Floor Bolts M6 x 1 25mm Long With Flat Washer...

Страница 24: ...a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WAR...

Отзывы: