background image

9

107064

OWNER’S MANUAL

INSTALLATION

Continued

Figure 11 - Inserting Fireplace Into Cabinet
Mantel

Figure 10 - Location of Nailing Flanges

Nailing
Flanges

Continued

Actual

Framing

Height

32 

3

/

8

"

33"

Front Width

34 

5

/

16

"

35 

1

/

2

"

Depth

16 

11

/

16

"

17 

3

/

4

"

35 

1

/

2

"

17 

3

/

4

"

33"

Figure 12 - Rough Opening for Installing
in Wall

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. If installing a mantel above the
fireplace, you must follow the clearances
shown in Figure 15,

 

page 10. Follow the

instructions below to install the fireplace in
this manner.

Figure 14 - Attaching Fireplace to Wall
Studs

Nailing Flanges

Nails or
Wood
Screws

39 3/8"

27 7/8"

55 5/8"  

35 1/2"

Figure 13 - Rough Opening for Installing
in Corner

1.

Frame in rough opening. Use dimen-
sions shown in Figure 12 for the rough
opening.

If installing in a corner, use dimensions
shown in Figure 13 for the rough open-
ing. The height is 33" which is the same
as the wall opening above.

2.

If using blower, install and properly
ground GA3555, three-prong 120 volt
electrical outlet, in fireplace. Follow
instructions included in kit (see Acces-
sories, 
pages 24 and 25).

3.

Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The flexible gas line must be the
last item installed on the gas piping. See
Installing Gas Piping to Fireplace Lo-
cation,
 page 10.

4.

Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.

5.

Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Sup-
ply,
 page 11.

6.

Plug electrical cord into electrical out-
let installed in step 2.

7.

Carefully insert fireplace into rough
opening.

8.

Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange (see Figure 14).

9.

Check all gas connections for leaks. See
Checking Gas Connections, page 12.

10. Install brass trim after final finishing

and/or painting of wall (see Figure 6,
page 7).

11. Carefully insert fireplace into cabinet

mantel. Be careful not to scratch or
damage hearth base, cabinet mantel, or
any laminate trim on hearth base. Re-
move protective material from top of
hearth base and from front of fireplace
(if any). 

Note:

 You can secure fireplace

to hearth or floor. Open lower louver.
Locate screw holes in bottom of base.
Tighten wood screws through these
holes and into hearth or floor.

12. Check all gas connections for leaks. See

Checking Gas Connections, page 12.

Содержание Comfort Glow LFP33PRA

Страница 1: ...justment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information consult a...

Страница 2: ...instructions in Cleaning and Main tenance page 18 9 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white p...

Страница 3: ...top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Chec...

Страница 4: ...Unusually Tight Construction Theairthatleaksarounddoorsandwindows mayprovideenoughfreshairforcombustion and ventilation However in buildings of PRODUCT FEATURES OPERATION This vent free fireplace is...

Страница 5: ...____ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual am...

Страница 6: ...rovide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl s...

Страница 7: ...crews two adjust ing plates with set screws and two shims in the hardware packet 3 Align shim under adjusting plate as shown in Figure 5 4 Slide one end of adjusting plate shim in slot on mitered edge...

Страница 8: ...earth top to run flexible gas line to fireplace see Figure 8 Make sure to locate access hole so cabi net mantel will cover it when installed Note You can secure base to floor us ing wood screws Counte...

Страница 9: ...see Acces sories pages 24 and 25 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The fl...

Страница 10: ...ling fireplace make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connec...

Страница 11: ...t is resistant to liquid pe troleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 17 Locate sediment trap where it is within reach for cleaning Install in pipi...

Страница 12: ...con nected 3 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 4 Check all joints of gas supply piping system Apply mixture of liquid soap and wat...

Страница 13: ...ure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the burner U bend 2 Locate pegs on the bottom of back log 2 Slide these pegs into the hol...

Страница 14: ...f re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 31 Installing Battery i...

Страница 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 36 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Страница 16: ...or loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the selector switch is in the ON position after the pilot is li...

Страница 17: ...ies pages 24 and 25 Follow instructionsincludedwiththeremotecontrol Figure 38 Pilot Ignitor Electrode Pilot Burner After lighting let pilot flame burn for about one minute Turn control knob to ON posi...

Страница 18: ...cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount...

Страница 19: ...ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ign...

Страница 20: ...irements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum...

Страница 21: ...statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces a c...

Страница 22: ...ay be low When Gas Quality Is Bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your l...

Страница 23: ...514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techs...

Страница 24: ...ERIMETER BRASS TRIM Not Shown GMC36F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medalli...

Страница 25: ...erated in a manually or thermostatically controlled mode Youcanturnthegaslogheateronand off without ever leaving the comfort of your easy chair BRASS TRIM ACCESSORY GA7090 Not Shown Optional with buil...

Страница 26: ...NVENTED PROPANE LP GAS FIREPLACE LFP33PRA ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33PRA 20 30 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 1 2 4 3 8 12 7 17 16 28 18 19 24 14 13 19 23 22...

Страница 27: ...rner Orifice Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 4 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1...

Страница 28: ...28 107064 UNVENTED PROPANE LP GAS FIREPLACE LFP33PRA 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33PRA...

Страница 29: ...K Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103207 0...

Страница 30: ...elated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL...

Отзывы: