background image

7

107064

OWNER’S MANUAL

INSTALLATION

Continued

Note: 

Your  Comfort Glow fireplace is

designed to be used in zero clearance instal-
lations. Wall or framing material can be
placed directly against any exterior surface
on the rear, sides, or top of your  fireplace,
except where standoff spacers are integrally
attached. If standoff spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

 WARNING: Never install the

fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace

• in high traffic areas
• in windy or drafty areas

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Figure 5 - Assembling Brass Trim

IMPORTANT:

 If you are recessing the fire-

box in a wall, do not attach brass trim at this
time. See page 9.

Note: 

The instructions below show assem-

bling and attaching brass trim to fireplace.
1.

Remove packaging from three pieces
of brass trim.

2.

Locate four brass screws, two adjust-
ing plates with set screws, and two
shims in the hardware packet.

3.

Align shim under adjusting plate as
shown in Figure 5.

4.

Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 5).

5.

Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 5).

ASSEMBLING AND
ATTACHING OPTIONAL
BRASS TRIM
(Included with Mantel
Accessory)

Side Brass
Trim

Top
Brass
Trim

Slot

Mitered Edge

Slot

Shim

Set Screws

Adjusting
Plate

6.

While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.

7.

Repeat steps 1 through 6 for other side.

8.

Tighten trim hanging screws (#10 x
6.25 shoulder) into holes in cabinets.
Place the assembled trim onto fireplace
cabinet. Align hanging notches on trim
with hanging screws on side of fire-
place (see Figure 6). Push trim firmly
into place, sliding hanging notches over
hanging screws.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).

IMPORTANT: 

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 4 through 6.

IMPORTANT:

 Make sure the fireplace is

level. If fireplace is not level, log set will not
work properly.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP gas, do not install fire-
place. Call dealer where you bought fire-
place for proper type fireplace.

ELECTRICAL HOOKUP

(Optional GA3750 Blower
Accessory )

This fireplace accepts a blower assembly
with an electrical cord. The electrical cord is
five feet in length. You must locate fireplace
within reach of a 120 volt grounded electrical
outlet. If not, you must install an electrical
outlet within reach of fireplace power cord.

Figure 6 - Attaching Brass Trim to
Fireplace

Trim
Hanging
Screws

Assembled
Brass Trim

Hanging
Notches
on Trim

Содержание Comfort Glow LFP33PRA

Страница 1: ...justment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information consult a...

Страница 2: ...instructions in Cleaning and Main tenance page 18 9 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white p...

Страница 3: ...top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Chec...

Страница 4: ...Unusually Tight Construction Theairthatleaksarounddoorsandwindows mayprovideenoughfreshairforcombustion and ventilation However in buildings of PRODUCT FEATURES OPERATION This vent free fireplace is...

Страница 5: ...____ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual am...

Страница 6: ...rovide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl s...

Страница 7: ...crews two adjust ing plates with set screws and two shims in the hardware packet 3 Align shim under adjusting plate as shown in Figure 5 4 Slide one end of adjusting plate shim in slot on mitered edge...

Страница 8: ...earth top to run flexible gas line to fireplace see Figure 8 Make sure to locate access hole so cabi net mantel will cover it when installed Note You can secure base to floor us ing wood screws Counte...

Страница 9: ...see Acces sories pages 24 and 25 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The fl...

Страница 10: ...ling fireplace make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connec...

Страница 11: ...t is resistant to liquid pe troleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 17 Locate sediment trap where it is within reach for cleaning Install in pipi...

Страница 12: ...con nected 3 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 4 Check all joints of gas supply piping system Apply mixture of liquid soap and wat...

Страница 13: ...ure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the burner U bend 2 Locate pegs on the bottom of back log 2 Slide these pegs into the hol...

Страница 14: ...f re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 31 Installing Battery i...

Страница 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 36 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Страница 16: ...or loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the selector switch is in the ON position after the pilot is li...

Страница 17: ...ies pages 24 and 25 Follow instructionsincludedwiththeremotecontrol Figure 38 Pilot Ignitor Electrode Pilot Burner After lighting let pilot flame burn for about one minute Turn control knob to ON posi...

Страница 18: ...cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount...

Страница 19: ...ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ign...

Страница 20: ...irements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum...

Страница 21: ...statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces a c...

Страница 22: ...ay be low When Gas Quality Is Bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your l...

Страница 23: ...514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techs...

Страница 24: ...ERIMETER BRASS TRIM Not Shown GMC36F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medalli...

Страница 25: ...erated in a manually or thermostatically controlled mode Youcanturnthegaslogheateronand off without ever leaving the comfort of your easy chair BRASS TRIM ACCESSORY GA7090 Not Shown Optional with buil...

Страница 26: ...NVENTED PROPANE LP GAS FIREPLACE LFP33PRA ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33PRA 20 30 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 1 2 4 3 8 12 7 17 16 28 18 19 24 14 13 19 23 22...

Страница 27: ...rner Orifice Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 4 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1...

Страница 28: ...28 107064 UNVENTED PROPANE LP GAS FIREPLACE LFP33PRA 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33PRA...

Страница 29: ...K Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103207 0...

Страница 30: ...elated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL...