VENTED NATURAL GAS LOGS

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 Early

signs of carbon monoxide poisoning re-
semble the flu, with headaches, dizziness,
or nausea. If you have these signs, the log set
may not be working properly. Get fresh air
at once!
 Have log set serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Natural Gas:

 Natural gas is odorless. An

odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.

Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this log set.

WARNING ICON

G 001

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this log set. Im-
proper use of this log set can cause
serious injury or death from burns,
fire, explosion, electrical shock,
and carbon monoxide poisoning.

 DANGER: Carbon monoxide

poisoning may lead to death!

 WARNING: Any change to this

log set or its controls can be
dangerous.

1.

This appliance, as supplied, is only for
use with the type of gas indicated on
the rating plate. This appliance is con-
vertible for use with propane/LP, using
the GA9053 or GA9153 pilot kit.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

3.

Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42 inches from the front, top, or sides
of the log set

• in high traffic areas
• in windy or drafty areas

4.

Before installing in a solid fuel burn-
ing fireplace, the chimney flue and fire-
box must be cleaned of soot, creosote,
ashes and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated.  Inspect chimney flue
for damage.

5.

You must operate this log set with a fire-
place screen in place. Make sure fireplace
screen is closed before running log set.

6.

This log set is designed to be smoke-
less. If logs ever appear to smoke, turn
off appliance and call a qualified ser-
vice person. 

Note:

 During initial op-

eration, slight smoking could occur due
to log curing and the burning of manu-
facturing residues. You may wish to add
more ventilation by opening a window.

7.

To reduce the creation of soot, follow
the instructions in Cleaning and Main-
tenance
, page 17.

8.

Do not allow fans to blow directly into
the fireplace. Avoid any drafts that al-
ter burner flame patterns. Ceiling fans
can create drafts that alter burner flame
patterns. Altered burner patterns can
increase sooting.

9.

Do not use a blower insert, heat ex-
changer insert or other accessory not
approved for use with this log set.

10. This log set needs fresh, outside air ven-

tilation to run properly. See Air for
Combustion and Ventilation
, pages 4
through 6.

11. Do not run log set

• where flammable liquids or vapors

are used or stored

• under dusty conditions

12. Do not burn solid fuel in the fireplace

after installing the log set. Do not use
this log set to cook food or burn paper
or other objects.

13. Log set becomes very hot when in use.

Keep children and adults away from hot
surface to avoid burns or clothing igni-
tion.  Log set will remain hot for a time
after shutdown. Allow surface to cool
before touching.

14. Carefully supervise young children

when they are in the room with log set.

15. Do not use appliance if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the room appliance and to replace
any part of the control system (if using
GA9053 or GA9153) and any gas con-
trol which has been under water.

16. To help prevent breakage, new logs

must be broken-in (see Curing logs
page 13).

17. Turn log set off and let cool before ser-

vicing, installing, or repairing. Only a
qualified service person should install,
service, or repair log set.

 WARNING: Keep flue open

when operating unit.

Содержание Comfort Glow CVTR18

Страница 1: ...rect installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only i...

Страница 2: ...d fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set w...

Страница 3: ...that can be purchased sepa rately for this log set You must use the millivolt valve safety pilot kit to use remote accessories with this appliance See Acces sories page 17 UNPACKING CAUTION Do not rem...

Страница 4: ...heatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is go...

Страница 5: ...combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support...

Страница 6: ...he two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and V...

Страница 7: ...must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical information regarding the installati...

Страница 8: ...s Needed Before installing log set make sure you have the items listed below piping check local codes sealant resistant to LP gas manual shutoff valve test gauge connection adjustable crescent wrench...

Страница 9: ...16 wrench 6 Slip the air restrictor over the 1 8 pipe nipple Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting Tighten with a 9 16 wrench 7 Place the grate...

Страница 10: ...alve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued rod to the front 9 Install valve cover to burner pan using screws provided 10 Install thermocouple pilot a...

Страница 11: ...e immedi ately Tighten or reassemble the loose connection s using pipe joint com pound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flam...

Страница 12: ...f you then smell gas STOP Fol low the safety information above If you don t smell gas go on to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the...

Страница 13: ...essed in for five 5 seconds Note You may be running this log set for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 sec onds This will allow air...

Страница 14: ...king sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas...

Страница 15: ...ce page 17 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP ga...

Страница 16: ...tatement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF positi...

Страница 17: ...onal sTechnicalServiceDe partment at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning t...

Страница 18: ...18 901049 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN CVTR18 CVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17...

Страница 19: ...Natural Gas 1 12 901761 01 901761 01 1 8 Hex Nipple 1 13 901760 01 901760 01 Manifold Block 1 14 901751 01 901751 01 Air Restrictor 1 15 901756 01 901756 01 Valve Cover 1 16 901056 01 901056 01 Brass...

Страница 20: ...s Parts and Service 2444 North 5th Street Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Depar...

Страница 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 22: ..._______________________ _______________________________________________________________________________________________ ________________________________________________________________________________...

Страница 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 24: ...log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...

Отзывы: