background image

13

901049

OWNER’S MANUAL

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the
gas shutoff valve counterclockwise

 to open or clockwise 

 to

close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise  
to the OFF position.

During the 2-3 hour appliance break-in
period, you may detect an odor from the
appliance as the various paints and com-
pounds used in the manufacturing of this
log set cure. This is a normal and tempo-
rary situation that is not cause for alarm.
However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn the logs in consecutive 1 hour pe-

riods raising the flame an additional
2" to full flame height for a total of
three hours.

CURING LOGS

Note:

 Operation instructions for GA9153

Remote Ready Valve/Pilot Kit will be
included with the Kit.

1.

STOP! Read the safety information,
page 12.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-
wise 

  to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas around log set
and near floor. If you smell gas,
STOP! See Safety information
, page 2
and Air For Combustion And Ventila-
tion
, pages 4 through 6. If you don’t
smell gas, go to the next step.

5.

 Turn control knob counterclockwise

 to the PILOT position and

press in. Keep control knob pressed
in for five (5) seconds.

Note:

 You may be running this log

set for the first time after hooking up
to gas supply. If so, the control knob
may need to be pressed in for 30 sec-
onds. This will allow air to bleed from
the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the rear of the front burner. If
needed, keep pressing ignitor button
until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

 to the ON position. Burner

should light. If burner does not light,
call a qualified service person.

OPERATING

INSTRUCTIONS FOR

GA9053

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

ON

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

OFF

On

Off

OFF

OFF

Pilot

Thermo-
couple

Figure 22 - Ignitor and Control Knob

Figure 23 - Thermocouple and Pilot

OPERATING
APPLIANCE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.

Turn control knob clockwise 
to the PILOT position.

2.

Press in and turn control clockwise

 to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise 

 to

the PILOT position.

Содержание Comfort Glow CVTR18

Страница 1: ...rect installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only i...

Страница 2: ...d fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set w...

Страница 3: ...that can be purchased sepa rately for this log set You must use the millivolt valve safety pilot kit to use remote accessories with this appliance See Acces sories page 17 UNPACKING CAUTION Do not rem...

Страница 4: ...heatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is go...

Страница 5: ...combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support...

Страница 6: ...he two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and V...

Страница 7: ...must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical information regarding the installati...

Страница 8: ...s Needed Before installing log set make sure you have the items listed below piping check local codes sealant resistant to LP gas manual shutoff valve test gauge connection adjustable crescent wrench...

Страница 9: ...16 wrench 6 Slip the air restrictor over the 1 8 pipe nipple Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting Tighten with a 9 16 wrench 7 Place the grate...

Страница 10: ...alve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued rod to the front 9 Install valve cover to burner pan using screws provided 10 Install thermocouple pilot a...

Страница 11: ...e immedi ately Tighten or reassemble the loose connection s using pipe joint com pound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flam...

Страница 12: ...f you then smell gas STOP Fol low the safety information above If you don t smell gas go on to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the...

Страница 13: ...essed in for five 5 seconds Note You may be running this log set for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 sec onds This will allow air...

Страница 14: ...king sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas...

Страница 15: ...ce page 17 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP ga...

Страница 16: ...tatement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF positi...

Страница 17: ...onal sTechnicalServiceDe partment at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning t...

Страница 18: ...18 901049 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN CVTR18 CVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17...

Страница 19: ...Natural Gas 1 12 901761 01 901761 01 1 8 Hex Nipple 1 13 901760 01 901760 01 Manifold Block 1 14 901751 01 901751 01 Air Restrictor 1 15 901756 01 901756 01 Valve Cover 1 16 901056 01 901056 01 Brass...

Страница 20: ...s Parts and Service 2444 North 5th Street Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Depar...

Страница 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 22: ..._______________________ _______________________________________________________________________________________________ ________________________________________________________________________________...

Страница 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 24: ...log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...

Отзывы: