LIMITED WARRANTY

COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase,
provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim
under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper
operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide
original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a
qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as
a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation
and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS
EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY
AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY
LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER
DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages,
so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

Model ____________________________________

Serial No. _________________________________

Date Purchased ____________________________

NOT A UPC

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make
no other warranty, expressed or implied.

104275 01

Содержание Comfort Glow CGP10RLA

Страница 1: ...alified installer service agency or the gas supplier WARNING This is an unvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti...

Страница 2: ...ts controls can be dan gerous 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane LP s...

Страница 3: ...plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Ox...

Страница 4: ...y iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecom...

Страница 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can...

Страница 6: ...23 1 Section5 3 AirforCombustionand Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controll...

Страница 7: ...nstalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may disco...

Страница 8: ...11 Installing Bottom Mounting Screw 1 16 Space Thin or Thick Wall thick wall shown Solid Wall Figure 8 Tightening Anchors Placing Heater on Mounting Screws 1 Locate two keyhole slots on back panel of...

Страница 9: ...pple Ground Joint Union From External Regulator 11 W C to 14 W C Pressure Equipment Shutoff Valve Sediment Trap Test Gauge Connection 3 Minimum Installsedimenttrapinsupplylineasshown in Figure 13 Loca...

Страница 10: ...1 Disconnect appliance with its appliance maingasvalve controlvalve andequip ment shutoff valve from gas supply pip ingsystem Pressuresinexcessof1 2psig will damage heater regulator 2 Cap off open end...

Страница 11: ...This will light pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH lo...

Страница 12: ...r small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months WARNING Turn off heater and let coo...

Страница 13: ...his prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace...

Страница 14: ...polish wax carpet cleaners or similar products POSSIBLE CAUSE 1 Burner orifice s is clogged 2 Burner orifice s diameter is too small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Bu...

Страница 15: ...paint hair spray glues etc see IMPORTANT statement above 2 Low fuel supply 3 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partia...

Страница 16: ...s Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat propane LP gas supply may be low When Gas Quality Is Bad pilot will not stay li...

Страница 17: ...616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542...

Страница 18: ...18 104275 PROPANE LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10RLA 7 2 7 1 ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B...

Страница 19: ...Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01 Tu...

Страница 20: ...n Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF...