background image

2

104275

PROPANE/LP GAS HEATER

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.

Surface of heater becomes very
hot when running heater. Keep
children and adults away from
hot surface to avoid burns or
clothing ignition. Heater will re-
main hot for a time after shut-
down. Allow surface to cool be-
fore touching.

Carefully supervise young chil-
dren when they are in the same
room with heater.

Make sure grill guard is in place
before running heater.

Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable
vapors and liquids.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

 WARNING: Do not use any

accessory not approved for use
with this heater.

SAFETY
INFORMATION

 WARNINGS

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, and/or nau-
sea. If you have these signs, the heater may
not be working properly. Get fresh air at
once!
 Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Propane/LP Gas:

 Propane/LP gas is odor-

less. An odor-making agent is added to pro-
pane/LP gas. The odor helps you detect a
propane/LP gas leak. However, the odor added
to propane/LP gas can fade. Propane/LP gas
may be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.

 DANGER: Carbon monoxide

poisoning may lead to death!

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, and car-
bon monoxide poisoning.

 WARNING: Any change to this

heater or its controls can be dan-
gerous.

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch;
• do not use any phone in your building
• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

4.

Heater shall not be installed in a bath-
room.

5.

Always run heater with control knob
at LOW or HIGH locked positions.
Never set control knob between locked
positions. Poor combustion and higher
levels of carbon monoxide may result.

6.

This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 4 through 6.

7.

Keep all air openings in the front and
bottom of heater clear and free of de-
bris. This will insure enough air for
proper combustion.

8.

If heater shuts off, do not relight until
you provide fresh, outside air. If heater
keeps shutting off, have it serviced.

9.

Do not run heater
• where flammable liquids or vapors

are used or stored

• under dusty conditions

10. Before using furniture polish, wax, car-

pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

11. Do not use heater if any part has been

under water. Immediately call a quali-
fied service technician to inspect the
room heater and to replace any part of
the control system and any gas control
which has been under water.

12. Turn off heater and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

13. Operating heater above elevations of

4,500 feet could cause pilot outage.

14. To prevent performance problems, do

not use propane/LP fuel tank of less
than 100 lbs. capacity.

Содержание Comfort Glow CGP10RLA

Страница 1: ...alified installer service agency or the gas supplier WARNING This is an unvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti...

Страница 2: ...ts controls can be dan gerous 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane LP s...

Страница 3: ...plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Ox...

Страница 4: ...y iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecom...

Страница 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can...

Страница 6: ...23 1 Section5 3 AirforCombustionand Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controll...

Страница 7: ...nstalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may disco...

Страница 8: ...11 Installing Bottom Mounting Screw 1 16 Space Thin or Thick Wall thick wall shown Solid Wall Figure 8 Tightening Anchors Placing Heater on Mounting Screws 1 Locate two keyhole slots on back panel of...

Страница 9: ...pple Ground Joint Union From External Regulator 11 W C to 14 W C Pressure Equipment Shutoff Valve Sediment Trap Test Gauge Connection 3 Minimum Installsedimenttrapinsupplylineasshown in Figure 13 Loca...

Страница 10: ...1 Disconnect appliance with its appliance maingasvalve controlvalve andequip ment shutoff valve from gas supply pip ingsystem Pressuresinexcessof1 2psig will damage heater regulator 2 Cap off open end...

Страница 11: ...This will light pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH lo...

Страница 12: ...r small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months WARNING Turn off heater and let coo...

Страница 13: ...his prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace...

Страница 14: ...polish wax carpet cleaners or similar products POSSIBLE CAUSE 1 Burner orifice s is clogged 2 Burner orifice s diameter is too small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Bu...

Страница 15: ...paint hair spray glues etc see IMPORTANT statement above 2 Low fuel supply 3 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partia...

Страница 16: ...s Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat propane LP gas supply may be low When Gas Quality Is Bad pilot will not stay li...

Страница 17: ...616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542...

Страница 18: ...18 104275 PROPANE LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10RLA 7 2 7 1 ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B...

Страница 19: ...Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01 Tu...

Страница 20: ...n Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF...

Отзывы: