background image

12

103873

Marking Screw Locations

1. Tape mounting bracket to wall where heater will be located. Make sure mounting

bracket is level.

30,000 Btu/Hr Model

20,000 Btu/Hr Models

2. Mark screw locations on wall (see Figure 8).

Note: 

Only mark last hole on each end of mounting bracket. Insert mounting

screws through these holes only.

3. Remove tape and mounting bracket from wall.

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: 

Wall anchors, mounting screws, and spacers are in hardware package. The

hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64" drill bit.
2. Place mounting bracket onto wall. Line up last hole on each end of bracket with

holes drilled in wall.

3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid
walls (concrete or masonry)
1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or

masonry), drill at least 1" deep.

2. Fold wall anchor as shown in Figure 9.

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

INSTALLING TO

WALL

Continued

Figure 9 - Folding Anchor

 WARNING

Maintain minimum clearances shown in Figure 8. If you can, provide
greater clearances from floor and joining wall.

18 3/4"

Min.

11"

Min.

16"

18 3/4"

Min.

7 1/4"

Min.

Adjoining Wall

16"

Adjoining Wall

Only Insert Mounting 

Screws Through Last 

Hole On Each End

Only Insert Mounting 

Screws Through Last 

Hole On Each End

Floor

Floor

Содержание Comfort Glow CGN20T

Страница 1: ...uctions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvente...

Страница 2: ...r the influence of alcohol and those at high altitudes Natural Gas Natural gas is odorless An odor making agent is added to natural gas The odor helps you detect a natural gas leak However the odor ad...

Страница 3: ...if not enough fresh air is available See Fresh Air for Combus tion and Ventilation pages 5 through 8 6 Keep air openings in front and bottom of heater clear and free of debris This will ensure enough...

Страница 4: ...ve heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUC...

Страница 5: ...space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are comm...

Страница 6: ...ted gas heater _________________ Btu Hr Gas fireplace logs _________________ Btu Hr Other gas appliances _________________ Btu Hr Total _________________ Btu Hr Example Gas water heater 40 000 Btu Hr...

Страница 7: ...nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 F...

Страница 8: ...the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openings f...

Страница 9: ...ure 4 page 10 If you can provide greater clearances from floor ceiling and joining wall You can locate heater on floor away from a wall An optional floor mounting stand is needed Purchase the floor mo...

Страница 10: ...ible Material 6 Left Side Right Side Figure 5 Attaching Thermostat Sensing Bulb Clamp Thermostat Sensing Bulb THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed inside the heater for...

Страница 11: ...two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to wall stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attachi...

Страница 12: ...ast hole on each end of bracket with holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attachi...

Страница 13: ...holes are near bottom on back panel of heater see Figure 12 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screws into hollow or solid wall insta...

Страница 14: ...rap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong...

Страница 15: ...cing Correct all leaks at once Continued Manual Shutoff Valve CONNECTING TO GAS SUPPLY Continued 3 Minimum Typical Inlet Pipe from Gas Meter 4 W C to 10 5 W C Pressure WARNING ICON G 001 WARNING Never...

Страница 16: ...l leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF po...

Страница 17: ...gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire...

Страница 18: ...ached to the front of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 22 t...

Страница 19: ...room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any heat level be...

Страница 20: ...flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down Thermocouple Pilot Burner Figure 18 Correct Pilot Flame Pattern P...

Страница 21: ...increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instructions at bottom of this page CORRECT FLAME PATTERN AT HIGH POSITION 1 2 GLASS HEIGHT Yellow Tipping BURN...

Страница 22: ...cessive lint from carpet ing bedding material etc WARNING ICON G 001 WARNING Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater W...

Страница 23: ...ontrol valve OBSERVED PROBLEM When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released POSSIBLE CAUSE 1 Gas supply t...

Страница 24: ...clean burner see Cleaning and Maintenance page 22 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate b...

Страница 25: ...king noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Moistu...

Страница 26: ...W x D Heater 23 5 x 18 5 x 8 0 23 5 x 25 9 x 8 0 Carton 25 8 x 21 3 x 10 1 25 8 x 28 7 x 10 1 Weight pounds Heater 22 30 Shipping 27 35 SPECIFICATIONS SERVICE HINTS When gas pressure is too low pilot...

Страница 27: ...reed to support our customer s needs by providing original replacement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portabl...

Страница 28: ...28 103873 12 ODS Pilot Assembly 12 1 12 2 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 17 19 20 21 22 23 24 16 25 26 18 CGN20T CGN20TL CGN30T CGN30TL...

Страница 29: ...98271 02 098271 02 Ignitor Cable 1 11 098249 01 098249 01 Nut M5 2 12 099440 05 099440 05 ODS Pilot Assembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098515 01 098515 01 Ignitor Electrode 1 13 1...

Страница 30: ...Manual shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND 20 000 Btu Hr Models CGN20TL GA4500L Ivory CGN20T GA4500 Champagne 30 000 Btu Hr Models CGN30TL GA4510L Ivory CGN30T GA4510 Champagne For lo...

Страница 31: ..._____ ___________________________________________________________________ ___________________________________________________________________ __________________________________________________________...

Страница 32: ...tation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE...

Отзывы: