WARRANTY INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

COMFORT GLOW VENT-FREE NATURAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for one (1) year  from
the date of first purchase, provided that the product has been properly installed, operated and maintained in
accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required
to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers
of this product and/or DESA International who will provide original factory replacement parts. Failure to use
original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in
accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts
that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by
improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to
repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD-
ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE
(1) YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS
HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL
SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on
damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

Содержание Comfort Glow CGN18RA

Страница 1: ...ot touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Страница 2: ...injury or death from burns fire explosion electrical shock and carbon monoxide poisoning WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of...

Страница 3: ...operly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 5 throug...

Страница 4: ...march Park Quincy MA 02269 Figure 1 Vent Free Natural Gas Heater Model CGN30D Shown PRODUCT FEATURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pi...

Страница 5: ...ur home All fuel burning appliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must...

Страница 6: ...heater ___________________ BTU Hr Gas fireplace logs ___________________ BTU Hr Other gas appliances ___________________ BTU Hr Total ___________________ BTU Hr Example Gas water heater 40 000 BTU Hr...

Страница 7: ...ILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilat ing to an adjoining unconfined space you must provide two permanent openings...

Страница 8: ...to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 9: ...Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 27 LOCATING HEATER This heater is designed to be mounted on a wall WARNING ICON G 001 WARNING M...

Страница 10: ...NING ICON G 001 CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locate heater where moving vehicle will not hit it For convenience and...

Страница 11: ...nt Panel Of Heater Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their centers At...

Страница 12: ...oles drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to wall anchor method For attaching...

Страница 13: ...Mounting Screws 1 Locate two bottom mounting holes These holes are near bottom on back panel of heater see Figure 11 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installi...

Страница 14: ...st be upstream from heater see Figure 12 page 15 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged h...

Страница 15: ...ess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe wh...

Страница 16: ...RE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 13 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joi...

Страница 17: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result i...

Страница 18: ...oud click when the control knob reaches the PILOT IGN position If pilot does not light turn control knob clockwise Clockwise to the OFF position repeat steps 5 and 6 If pilot does not stay lit after s...

Страница 19: ...ion WARNING ICON G 001 CAUTION Do not try to adjust heating levels by using the manual shut off valve LOW OFF PILOT IGN MED OFF PILOT IGN HIGH OFF PILOT IGN OFF OFF HIGH MED LOW Control Knob CGN18RA C...

Страница 20: ...e control knob TO TURN OFF GAS TO APPLIANCE OPERATING HEATER Continued INSPECTING BURNER Check pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 18 shows a correct pilot fl...

Страница 21: ...shows an incorrect burner flame pattern Figure 20 Correct Burner Flame Pattern Figure 21 Incorrect Burner Flame Pattern Bad Burner Pattern 5 Plaque GRH OV 019A If burner flame pattern is incorrect as...

Страница 22: ...s of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material etc WARNING ICON G 0...

Страница 23: ...hermo couple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple dam aged 7 Cont...

Страница 24: ...nance page 22 or re place burner orifice s 2 Contact local natural gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local natural gas company 3 Turn control knob until i...

Страница 25: ...Warn ing statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warn ing statement at top of page 2 Control valve defective 1...

Страница 26: ...0 When calling DESA International have ready your name your address model number of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will a...

Страница 27: ...the address listed on the back page of this manual Send a check for 5 00 payable to DESA International Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Departme...

Страница 28: ...EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model CGN18RA 13 17 13 16 ODS PILOT BURNER ASSEMBLY 1 2 3 11 6 4 8 5 6 7 12 13 9 10 14 A B C 13 1 13 2 13 3 13 10 13 4 13 5 13 6 13 7 13 8 13 9 13 14 13 13 1...

Страница 29: ...ob 1 13 See Detail Burner Assembly 1 13 1 099218 01 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 03 Injector 3 13 4 099048 01 Tubing Valve to plaque A 1 13 5 099049 01 Tubing Valve to plaq...

Страница 30: ...D VIEW ILLUSTRATED PARTS BREAKDOWN Model CGN30D 13 17 13 16 ODS PILOT BURNER ASSEMBLY E D C 13 1 13 2 13 3 13 9 13 4 13 5 13 7 13 6 13 18 13 8 13 10 13 14 13 13 13 12 13 15 13 11 B A 1 2 3 11 6 13 4 8...

Страница 31: ...99218 02 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 02 Injector 5 13 4 099052 01 Tubing Valve to Plaque B D 1 13 5 099053 01 Tubing Valve to Plaque C 1 13 6 099057 01 Pressure Tap Fittin...

Страница 32: ...This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance...