Содержание Comfort Glow CGG2618P

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department Installation and service must be per formed by a qualified instal...

Страница 2: ...chimney flue for damage If damaged operate heater with flue damper closed 7 If fireplace has glass doors never operate this heater with glass doors closed If you operate heater with doors closed heat...

Страница 3: ...ough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteries or other sources to light heater Figure 1 Vent Ft_e Gas Log Heater LOCAL CODES Install an...

Страница 4: ...will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for com bustion and ventilatio...

Страница 5: ...ented gas heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 33 000 Btu Hr Total 73 000 Btu Hr Do not include dire...

Страница 6: ...space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide...

Страница 7: ...front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This heater cre ates warm air currents These cur rents move heat to wall surfaces next to heater Installing heat...

Страница 8: ...materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have non combustible material behind it Non combustible mate rial must extend at least 8 up for all mo...

Страница 9: ...n Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clear ances shown in Figur...

Страница 10: ...t the clearance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You prefer vented operation If reasons number 1 or 2 above apply to you...

Страница 11: ...ith wrench when connecting fittings 2 Position heater base assembly in fireplace exe as oo euro allowed by local codes Figure 11 Attaching Flexible Gas Hose to Heater Gas Regulator Masonry Screw Figur...

Страница 12: ...sealant lighdy to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves _k CAUTION Use pipe joint seal ant that is resistant t...

Страница 13: ...eater pages 14 through 16 Thermostat Controlled Models or pages 16 through 17 Variable Manually Controlled Models Check all other internal joints for leaks Turn off heater see To Turn Off Gas to Appli...

Страница 14: ...19 Installing Top Log OPERATING HEATER Thermostat Controlled Models FOR YOUR SAFETY I READ BEFORE LIGHTING _lh WARNING If you do not fol low these instructions exactly a fire or explosion may result c...

Страница 15: ...lot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 16 7 Kee...

Страница 16: ...light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cann...

Страница 17: ...ugh 7 Push in and turn control knob counterclockwise _ to the HIGH position Both burners should light Set control knob to desired setting Ignitor Button Control Knob Figure 23 Control Knob and Ignitor...

Страница 18: ...ly by a quali fled service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material etc Figure 25 Correct Pilot Flame Pattern Thermocouple Pilot Burner NOTIC...

Страница 19: ...lot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue...

Страница 20: ...ne_ 2 Replace damaged burner 3 Gas regulator defective 3 Replace gas regulator Yellow flame in front burner during burner 1 Not enough air 1 Check burner s for dirt and debris If combustion found clea...

Страница 21: ...dor causing products while heater carpet etc See IMPORTANTstatement is running above 2 Low fuel supply 3 Gas leak See Warning statement at top of page 2 Refill supply tank 3 Locate and correct all lea...

Страница 22: ...adhesive backed mounting clip 3 With 5 16 hex driver or socket loosen the thermostat screw Carefully slide the thermostat sensing bulb out of the retaining clamp see Figure 31 Note Do not remove the s...

Страница 23: ...you have decided on a location clean the area thoroughly Remove the paper backing from the adhesive on back of mounting clip Press the clip into the new location so that the thermostat sensing bulb wi...

Страница 24: ...91 Parts Department Four Flags Power Products 1115 Stateline Road Nile3 Ml 49120 616 684 2697 Parts Only Master Parts Distributors 1184 Wilson Ave NW Walker MI 49504 616 791 0505 U S 1 800 446 1446 Fa...

Страница 25: ...VALVE GA5010 For all models Manual shutoff valve with 1 8 NPT rap Fits 1 2 NPT pipe BLACK FIREPLACE HOOD GA6050 For all models Helps deflect heat away from mantel or wall above fireplace BRASS FIREPL...

Страница 26: ...UNVENTED VENT FREE GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models 4 27 27 1 27 2 21 7 6 10 29 8 I 11 13 CGG2618P 1 _ CGG3324P _ CGG3630P 18 19 20 26 i_4_...

Страница 27: ...03 098354 01 098354 01 098462 03 098462 03 098325 01 098325 01 098508 01 098508 01 102568 02 102568 02 101005 01 101005 01 Ml1084 26 Ml1084 26 101004 01 101004 02 101004 02 101004 06 i 102258 01 10225...

Страница 28: ...UNVENTED VENT FREE GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN Thermostat Controlled Models 13 10 CGG3324PT 12 27 28 fo34_...

Страница 29: ...1 101004 01 101004 02 102811 01 099387 09 102255 01 QTY Rear Log 1 1 Bottom Mid Log 2 1 Front Log 3 1 Top Log 4 1 Heat Shield 1 Screw 5 O D S Pilot 1 Ignitor 1 Thermocouple 1 Nut 4 Pilot Bracket 1 Fro...

Страница 30: ...UNVENTED VENT FREE GAS LOG HEATER NOTES 30 _os _...

Страница 31: ...OWNER S MANUAL...

Страница 32: ...structions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or par_ that fail or become damaged as a result of misuse ac...