27
102664
CLEANING
AND
MAINTENANCE
WARNING ICON
G 001
WARNING
Turn off fireplace and let cool before cleaning.
OBSERVED
PROBLEM
When ignitor button
is pressed, there is no
spark at ODS/pilot
WARNING ICON
G 001
CAUTION
You must keep control areas, burners, and circulating air pas-
sageways of fireplace clean. Inspect these areas of fireplace
before each use. Have fireplace inspected yearly by a qualified
service person. Fireplace may need more frequent cleaning due to
excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNERS
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to
properly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
TROUBLE-
SHOOTING
Note: All troubleshooting
items are listed in order of
operation.
WARNING ICON
G 001
WARNING
Turn off fireplace and let cool before servicing. Only a qualified
service person should service and repair fireplace.
WARNING ICON
G 001
CAUTION
Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.
Continued
POSSIBLE
CAUSE
1. Ignitor cable pinched or
wet
2. Ignitor electrode not con-
nected to ignitor cable
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Ignitor electrode broken
6. Bad piezo ignitor
7. Ignitor electrode posi-
tioned wrong
REMEDY
1. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry
2. Reconnect ignitor cable
3. Tighten nut holding
piezo ignitor to base
panel of log set. Nut is
located behind base
panel.
4. Replace ignitor cable
5. Replace ignitor
6. Replace piezo ignitor
7. Replace ignitor