INSTALLATION

Installing Variable Speed Blower Accessory (Cont.)

Installing Thermostatic Blower Accessory

INSTALLATION

Continued

Operating the Blower

Light your gas appliance with the blower off. After about 15
minutes, turn the blower on to deliver heated air at the top louvers.
The blower features a variable control which allows you to select the
speed you desire.

Note:

 Periodically check the louvers of the fire-

box and remove any dust, dirt, or other obstructions.

101584-05

120 Vac.   60 Hz. .  78 Amps
DESA International, Bowling Green, KY

 WARNING: Never attempt to service heater while it is plugged in, oper-

ating, or hot. Burns and electrical shock could result. Only a qualified ser-
vice person should service or repair heater.

If any of the original wire as supplied with the appliance must be replaced, it must be
replaced with 105°C wire or it’s equivalent.

 WARNING: Label all wires prior to disconnection when servicing con-

trols. Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.

Variable

Fan Switch 

White

White

Black

Green

On

110/115 

V.A.C.

Blower

Motor

Black

Black

Black

Off

Figure 17 - Location of Wiring Diagram Decal 3" from Blower

1.

If fireplace screen and floor are still installed, see Removing
Fireplace Screen and Floor Assembly
, page 8.

NOTICE: Shut off gas supply and disconnect heater
from gas supply if installing blower in previously
installed fireplace. Contact a qualified service person
to do this.

INSTALLING THERMOSTATIC BLOWER
ACCESSORY

2.

Using screw provided, attach green ground wire from speed
control cord to blower housing. Tighten screw securely (see
Figure 18).

3.

Place the blower against lower rear wall of firebox outer wrap-
per with the exhaust port directed upward. Align the holes in
top mounting tabs of blower with holes in wall of wrapper
(see Figure 19, page 14). Using two #8 screws provided, mount
blower and tighten screws firmly.

4.

Remove the three screws (do not discard) and cover plate from
center of firebox wrapper rear wall. Discard this cover plate
(see Figure 18).

5.

Mount the supplied thermostatic switch and cover assembly
into firebox wrapper wall. Do this by feeding terminal ends of
wire harness into the hole. Allow wires to fall to bottom of
firebox cavity (see Figure 18).

6.

Using three screws from step 7, attach switch and cover as-
sembly to firebox wrapper rear wall. Tighten screws firmly
(see Figure 18).

7.

Firmly attach red wire from the thermostatic switch and cover
assembly to either of the terminals on the blower motor (see
Figure 18).

8.

Firmly attach black wire from speed control cord to blue wire
from thermostatic switch and cover assembly (see Figure 18).

9.

Firmly attach white wire from speed control cord to remaining
terminal on blower motor (see Figure 18).

Figure 18 - Installing Switch and Cover Assembly, and Speed
Control

Va

ria

ble

Fa

n S

wi

tch

 

W

hit

e

W

hit

e

Bla

ck

Gr

ee

n

On

11

0/1

15

 

V.

A.

C.

Blo

we

r

Mo

to

r

Bla

ck

Bla

ck

Bla

ck

Of

f

Wiring
Diagram

Thermostatic Switch
and Cover Assembly

Red
Wire

Blue
Wire

Black
Wire

Green
Wire

White
Wire

Speed Control

Содержание Comfort Glow CGEFP33NR

Страница 1: ...icemustbeperformedbyaquali fied installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to thi...

Страница 2: ...patterns Altered burner patterns can cause sooting WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this fireplace Due to high temperatures the app...

Страница 3: ...This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is availabl...

Страница 4: ...at loss out a vent or up a chimney Heat is generated by both realistic flames and glowing embers When used without the optional blower the fireplace requires no electricity making it ideal for emergen...

Страница 5: ...ess provisions are provided for adequate combus tion and ventilation air Read the following instruc tions to insure proper fresh air for this and other fuel burning appliances in your home Unusually t...

Страница 6: ...Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the s...

Страница 7: ...A qualified service person must in stall fireplace Follow all local codes WARNING Never install the fireplace in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or o...

Страница 8: ...TALLATION Check Gas Type Electrical Hookup Installation Clearances Installation Sequence Removing Fireplace Screen And Floor Assembly INSTALLATION SEQUENCE After unpacking fireplace see Unpacking page...

Страница 9: ...Bushings Hole in Floor Support Bracket Hole in Outer Casing RELOCATING WALL SWITCH Note The decorative wall switch plate supplied is white The wall switch plate may be painted to match your decor The...

Страница 10: ...e Firebox Bottom Wall Switch Plate Assy Hole in Outer Casing Hole in Floor Support Bracket Mounting Wall Switch to Wall for Recessed Fireplace 7 Create three openings on wall according to Template 1 p...

Страница 11: ...corners of the rectangle may be round IMPORTANT Do not exceed the size of the rectangle on template 12 Carefully pass switch plate assembly through rectangular open ing from inside mantel see Figure...

Страница 12: ...all electrical cords are completely clear of the blower wheel and that there are no other foreign objects in blower wheel Turn blower on and check for opera tion Turn blower off by rotating knob fully...

Страница 13: ...lledfireplace Contactaqualifiedserviceperson to do this INSTALLING THERMOSTATIC BLOWER ACCESSORY 2 Using screw provided attach green ground wire from speed control cord to blower housing Tighten screw...

Страница 14: ...e power cord through plastic bushings and plug the power cord into a prop erly grounded three prong wall receptacle near the firebox b If your fireplace system installation is recessed and if an outle...

Страница 15: ...will not turn on and off at the same time The fireplace may run for several minutes before the blower turns on After the heater modulates to the pilot position the blower will continue to run The blo...

Страница 16: ...local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Figure 24 External Regulator with Vent Pointing Down Propan...

Страница 17: ...ve Provided by Installer Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve con trol valve and equipment sh...

Страница 18: ...nstallation loca tion Cut an access hole in hearth top to run flexible gas line to fireplace see Figure 30 Make sure to locate access hole so cabinet mantel will cover it when installed Note You can s...

Страница 19: ...the clearances shown in Figure 37 page 20 Follow the instructions below to install the fireplace in this manner Actual Framing Height 32 3 8 33 Front Width 34 5 16 35 1 2 Depth 16 11 16 17 3 4 1 Frame...

Страница 20: ...combustible Material May Project Off this Surface above the Firebox Hood Mantel Shelf 13 16 19 21 2 1 2 6 8 10 Note All vertical measurements are from top of fireplace hood opening to bottom of mantel...

Страница 21: ...check to ensure that no flame comes in contact with any log With the heater set to HI check to see if flames contact any log If so reposition logs accord ing to the log installation instructions in t...

Страница 22: ...specifically approved with this heater may result in property damage or personal injury CAUTION Do not remove the warning and in struction labels attached to the heater base assem bly These markings c...

Страница 23: ...low these instructions exactly a fire or explosion may result causing prop erty damage personal injury or loss of life A This appliance has a pilot which lights automatically when using the supplied w...

Страница 24: ...igure 51 Control Locations Manual Ignition Bypass Switch Up is for Remote Control ON OFF Button HI LO Button Wall Switch LED B Using Hand Held Wireless Remote Control 1 Set manual ignition bypass swit...

Страница 25: ...ral attempts to light the pilot fail contact a qualified service person or gas supplier for repairs 8 When thermocouple is heated release override handle The main burner will immediately light on high...

Страница 26: ...spect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding mate...

Страница 27: ...ING AND MAINTENANCE Continued CLEANING AND MAINTENANCE Cleaning Pilot Air Inlet Hole Logs SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE SPECIFICATIONS Btu Variable 20 000 33 000 Type Gas Natural CG E...

Страница 28: ...in OFF position 4 Make sure power cord is plugged into electrical outlet and outlet has power 5 Reconnect ignitor cable 6 Replace ignitor cable 7 Replace pilot assembly 8 Replace pilot assembly 1 Mak...

Страница 29: ...ages 26 and 27 or re place ODS pilot assembly 6 Replace gas regulator 1 Turn control knob fully counterclock wise 2 After ODS pilot lights hold control knob for 30 seconds 3 Fully open equipment shuto...

Страница 30: ...ingwithinburner box or on adjacent walls or furniture REMEDY 1 This is common with most fireplaces If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using o...

Страница 31: ...ur address model and serial numbers of your fireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factor...

Страница 32: ...12 23 41 42 24 43 39 13 31 30 11 10 7 38 5 27 26 6 13 15 32 14 18 37 28 33 20 21 19 35 36 9 17 29 34 22 25 16 8 1 2 4 3 40 44 ILLUSTRATED PARTS BREAKDOWN REMOTE CONTROL LOG BASE ASSEMBLY MODELS EFP33...

Страница 33: ...102334 01 Palnut Fastener 1 20 107562 01 107562 01 Switch and Wire Assembly 1 21 107685 01 107685 01 Bracket Switch and Piezo 1 22 101628 03 101628 03 Flexible Connector 1 23 098544 01 098544 01 Wire...

Страница 34: ...ch com For more information visit www desatech com 34 ILLUSTRATED PARTS BREAKDOWN Models EFP33PR NR and CGEFP33PR NR ILLUSTRATED PARTS BREAKDOWN FIREBOX MODELS EFP33PR NR AND CGEFP33PR NR 1 2 3 4 10 1...

Страница 35: ...UMBER DESCRIPTION QTY 1 101357 03 Top Outer Casing 1 2 Outer Casing 1 3 Right Front Side 1 4 Left Front Side 1 5 098304 01 Phillips Pan Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Fir...

Страница 36: ...gh and or unfinished mantel or wall opening edges etc Included with mantel accessory INFORMATION VIDEO 108917 01 For all models A care and maintenance video is available by calling 1 866 672 6040 CORN...

Страница 37: ...HEARTH BASE G3008F Series Walnut Finished G3009U Series Unfinished G3010F Series Oak Finished For all models The corner hearth base is designed for use with the corner mantels to create a handsome ris...

Страница 38: ...______________________________________________________ _______________________________________________________________________________________________ _________________________________________________...

Страница 39: ...r more information visit www desatech com 39 39 Template 1 Relocating Wall Switch to Hollow Room Wall Template2 RelocatingWallSwitchtoSideWallof Mantel 4 3 4 4 3 4 3 3 4 3 8 3 3 4 3 8 3 16 3 4 3 4 3 8...

Страница 40: ...108117 01H For more information visit www desatech com For more information visit www desatech com 40 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 41: ...ted College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to...

Страница 42: ...108117 01H For more information visit www desatech com For more information visit www desatech com 42 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TM TAPE TAPE...

Страница 43: ...________________________________________________________ _______________________________________________________________________________________________ _______________________________________________...

Страница 44: ...more information visit www desatech com For more information visit www desatech com 44 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 108117 01 Rev H 02 03 NOT A UPC...

Отзывы: