background image

26

104306

UVENTED NATURAL GAS LOG HEATER

CGD3924NR, CGB3924NR and CGB3930NR

Note:

 Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at
1-800-DESA LOG (1-800-337-2564).

REPLACEMENT
PARTS

These Parts Centrals are privately owned businesses. They have agreed to support our
customer’s needs by providing original replacement parts and accessories. When calling a
Parts Central, ask for the Parts Department.

Baltimore Electric

1348 Dixwell Avenue
Hamden, CT 06514
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts

342 N. County Rd. 400 East
Valparaiso, IN 46383
All States
219-462-7441
1-800-362-6951

FBD

1349 Adams St.
Bowling Green, KY 42103
502-846-1199
1-800-654-8534

Four Flags Power Products

1115 Stateline Road
Niles, MI 49120
616-684-2697
1-800-268-4983
Parts Only

Master Parts Distribution

1184 Wilson Ave. NW
Grand Rapids, MI 49504
616-791-8270
1-800-446-1446

Washer Equipment Co.

1715 Main Street
Kansas City, MO 64108
KS, MO, AR
816-842-3911

East Coast Energy Products

707 Broadway
W. Long Branch, NJ 07764
732-870-8809
1-800-755-8809

Tarantin Tank Co.

P.O. Box 6129
Freehold, NJ 07728
908-780-9340
1-800-922-0724

Dayton Hardware

P.O. Box 275
North Dayton Station
Dayton, OH 45404
All States
937-258-3721
OH 1-800-762-3426

Halco Enterprises

208 Carter Drive, Unit 21
West Chester, PA 19382
610-430-7717
1-800-368-0803

LA Porte’s Parts & Service

2444 N. 5th Street
Hartsville, SC 29550
803-332-0191
Parts Department

Cans Unlimited, Inc.

P.O. Box 645
Taylor, SC 29687
All States
803-879-3009
1-800-845-5301

Heater and Fireplace Store

1922 N Route 9
Cape May Court, NJ 08210
609-624-0678
Parts Department

PARTS CENTRAL

When calling DESA International, have
ready

• your name

• your address

• model number of your heater

• how heater was malfunctioning

• type of gas used (propane or natural gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see Below) or call DESA
International’s Parts Department at 1-800-
972-7879 for referral information.

When calling DESA International, have
ready

• model number of your heater

• the replacement part number

Содержание Comfort Glow CGB3924NR

Страница 1: ...ATERS CGD3924NR CGB3924NR CGB3930NR 24 and 30 Remote Controlled Model P I L O T O F F O N LO REMOTE OFF HI OWNER S OPERATION AND INSTALLATION MANUAL WARNING If the information in this manual is not fo...

Страница 2: ...7 You must operate this heater with a fire place screen in place Make sure fire place screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smok...

Страница 3: ...teries or other sources to light heater 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by burners This could damage heater Always handle base assembly by...

Страница 4: ...tion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings expo...

Страница 5: ...irect vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ________...

Страница 6: ...rom Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items direc...

Страница 7: ...ntilation pages 4 through 6 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install heater Call dealer where you bought heater for proper type heater NOTICE Stateorloc...

Страница 8: ...e opening Non combus tible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have non combus tible material behind it Non combustible materialmustextend...

Страница 9: ...ances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel 14 Min Combustible Material Non Combustible Mat...

Страница 10: ...ng Masonry Screw Mounting Flanges Installation Items Needed hardware package provided with heater approved flexible gas hose not provided if allowed by local codes sealant resistant to propane LP gas...

Страница 11: ...cate sedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is...

Страница 12: ...ry housing 3 Replace battery cover onto remote con trol unit Figure 15 Installing 9 Volt Battery In Receiver Battery Cover Terminal Wires 9 Volt Battery Remote Control Unit Battery Housing Receiver Te...

Страница 13: ...se and the cutout area is centered over the burner U bend 3 Locate the recesses on the back of the front log 3 Fit these recesses be tween the posts of the grate base see Figure 19 4 Locate the notche...

Страница 14: ...that no flame comes in contact with any log If so repo sition logs according to the log installation instructions in this manual Flames contacting logs will create soot 1 Place the base of the middle...

Страница 15: ...window to vent smell Thiswillonlylastafewhours Note Homeowners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be ti...

Страница 16: ...s and keep the pilot lit by doing one of the following Turn control knob clockwise to the PILOT position UseremotecontrolmanualOFFbutton Set remote selector switch in the OFF position Ignitor Electrod...

Страница 17: ...tedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting pet hair etc ODS PILOT AND BURNER Use a vacuum cleaner or small soft bristled brush to...

Страница 18: ...e B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinch...

Страница 19: ...e 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installation cl...

Страница 20: ...PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF posi...

Страница 21: ...ter will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local natural gas supplier SERVICE HINTS WIRING DIAGRAM Receiver White On Off Remote Red Red White...

Страница 22: ...3924NR and CGB3930NR ILLUSTRATED PARTS BREAKDOWN CGD3924NR 7 16 16 17 25 16 3 2 1 4 11 21 10 9 12 15 8 19 18 20 6 14 5 13 27 26 26 RE MOTE OFF ON 22 23 24 O F F P I L O T O N H I L O O F F P I L O T O...

Страница 23: ...2772 01 Burner 1 13 099387 12 Pilot Tube Valve to regulator 1 14 103781 01 Gas Control Valve 1 15 103345 01 Lower Bracket 1 16 M11084 38 Screw 8 x 38 7 17 102775 06CK Painted Base Assembly 1 18 098271...

Страница 24: ...and CGB3930NR ILLUSTRATED PARTS BREAKDOWN CGB3924NR CGB3930NR 28 16 16 17 25 16 5 4 1 2 3 11 21 10 9 12 15 8 19 18 20 7 14 6 13 27 26 26 RE MOTE OFF ON 22 23 24 O F F P I L O T O N H I L O O F F P I...

Страница 25: ...K 102775 06CK Painted Base Assembly 1 18 098271 07 098271 07 Ignitor Cable 1 19 102445 01 102445 01 Piezo Ignitor 1 20 103823 01 103823 01 Remote Set Incl Transmitter 1 21 104099 01 104099 01 Heat Shi...

Страница 26: ...Main Street Kansas City MO 64108 KS MO AR 816 842 3911 East Coast Energy Products 707 Broadway W Long Branch NJ 07764 732 870 8809 1 800 755 8809 Tarantin Tank Co P O Box 6129 Freehold NJ 07728 908 78...

Страница 27: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 28: ...h other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHE PRODUCT THIS EXPRESS WARRANTY EXCLU...

Отзывы: