Lighting Instructions
To Turn Off Gas To Appliance
Manual Lighting Procedure
LIGHTING
INSTRUCTIONS
1.
STOP! Read the safety information on page 16, column 2.
2.
Make sure equipment shutoff valve is fully open.
3.
Set switch in OFF position.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Open a
window to vent smell. This will only last a few hours.
WARNING: Burner will come on automatically
within one minute when the selector switch is in the
ON position after the pilot is lit.
4.
Press in and turn control knob clockwise
to the
OFF position.
5.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information on page 16, column 2. If
you don’t smell gas, go to the next step.
6.
Press in and turn control knob counterclockwise
to the PILOT position. Press in control knob for five (5)
seconds (see Figure 32).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
7.
With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure.
8.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 4 through 8.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
WARNING: Make sure the selector switch is in the
OFF position when you are away from home for long
periods of time. Heater will come on automatically
with selector switch in the ON position.
Figure 33 - Pilot
Ignitor
Electrode
Pilot Burner
Figure 32 - Control Knob and Ignitor Button Location (Shown as
Supplied, No Control Options)
O
F
F
PIL
OT
O
N
L O
I H
AUTO
OFF
ON
Control Knob
Ignitor Button
Selector Switch
Flame Adjustment Knob
9.
Slightly push in and turn control knob counterclockwise
to the ON position.
10. Wait one minute and switch selector switch to the ON posi-
tion to light burner.
11. Set flame adjustment knob to any level between HI and LO.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position
2b.
If Using Optional Hand-Held Remote:
Set selector switch
in the OFF position to keep from draining battery.
Shutting Off Burner Only (pilot stays lit)
You may shut off the burner and keep the pilot lit by doing one
of the following:
1.
Turn control knob clockwise
to the PILOT position.
2.
Use remote control manual OFF button.
3.
Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.
Follow steps 1 through 6 under Lighting Instructions.
2.
Depress control knob and light pilot with match.
3.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 through 11 under Lighting Instructions.