background image

www.desatech.com

113101-01E

3

3

2

18

20

21

19

12

8

9

10

22

19

7

14

6

22

22

17

5

20

15

16

11

13

1

4

ILLUStRAtED PARtS bREAKDOWN

VARIABLE MANUALLY-CONTROLLED WINCHESTER OAK MODELS 
CGS2718NA, CGS2718pA 

CGS3124NA, CGS3124PA

 

SGS3124NA, SGS3124PA

Содержание CGS2718NA

Страница 1: ...he gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier IN...

Страница 2: ...supplier WARNING This appliance is for installation only in a solid fuel burning mason ry or UL127 factory built fireplaceorinalistedvent lessfireboxenclosure Itis design certified for these installat...

Страница 3: ...manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchange...

Страница 4: ...er 8 If fireplace has glass doors never operate this heater with glass doors closed If you operate heaterwithdoorsclosed heatbuildupinsidefire placewillcauseglasstoburst Makesurethereare no obstructio...

Страница 5: ...ined space or unusually tight con struction unless provisions are provided for adequate combus tionandventilationair Readthe following instructions to insure proper fresh air for this and other fuel b...

Страница 6: ...3 1 NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and...

Страница 7: ...54Section5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined sp...

Страница 8: ...o pane LP gas Field conversion is not permitted INSTALLATION AND CLEARANCES Vent Free Operation Only WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling an...

Страница 9: ...ontrol heaters may be used as a vented product If so you must always run heater with chimney flue damper open If running heater with damper open noncombustiblematerialabovefire place opening is not ne...

Страница 10: ...6 and Figure 7 see page 11 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory fo...

Страница 11: ...ombustible Material Figure 9 Minimum Fireplace Clearances Above Combustible Flooring Figure 8 Minimum Fireplace Clearances If Installed at Floor Level NOTICE Ifyourinstallationdoes not meet the minimu...

Страница 12: ...operation 3 You prefer vented operation If reasons number 1 or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory to order see Accessories p...

Страница 13: ...6 5 Center heater base and logs front to front and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through holes in mount ing brackets see Figure 12...

Страница 14: ...upstream from heater see Figure 14 IMPORTANT Installequipmentshutoffvalveinan accessible location The main gas valve is for turn ing on or shutting off the gas to the appliance Check your building cod...

Страница 15: ...ne LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply a commercial leak detection solution to al...

Страница 16: ...y CAUTION After installa tion and periodically thereafter check to ensure that no flame comes in contact with any log WiththeheatersettoHigh check toseeifflamescontactanylog If so reposition logs acco...

Страница 17: ...you identify the log when installing It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with heater 1 Place the base of the middle log 1 in the...

Страница 18: ...ting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle o...

Страница 19: ...18 column 2 If you don t smell gas go to the next step OPERATING HEATER Continued 5 Slightly depress and turn control knob counterclockwise to the PILOT position Press in control knob for five 5 secon...

Страница 20: ...y B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not...

Страница 21: ...ockwise to the PILOT position Press in control knob for five 5 seconds see Figure 28 OPERATING HEATER Continued Note You may be running this heater for the first time after hooking up to gas sup ply I...

Страница 22: ...rrect pilot flame pat tern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down BURNER PRIMARY AIR...

Страница 23: ...or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the directions on the can If you don t follow direct...

Страница 24: ...al numbers of your heater ready You can also visit DESAHeating Products techni cal service web site at www desatech com Service Hints When Gas Pressure Is Too Low pilot will not stay lit burners will...

Страница 25: ...in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When igni...

Страница 26: ...local natural or pro pane LP gas company 1 Contact local natural or pro pane LP gas company 2 Clean burner see Cleaning and Maintenance page 23 or replace burner orifice 1 Clean burner see Cleaning a...

Страница 27: ...e burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 8 4 Clean burner see Cleaning and Maintenanc...

Страница 28: ...Locate and correct all leaks see Checking Gas Connec tions page 15 1 Open window and or door for ventilation 2 Contact local natural or pro pane LP gas company 3 Clean ODS pilot see Cleaning and Main...

Страница 29: ...ing the thermostat sensing bulb IMPORTANT Do not force or bend the thermostat sensing bulb or capillary 3 The thermostat sensing bulb may be located to thelowerrightfrontsideoffireplace Determine loca...

Страница 30: ...o Piezo Manifold Pressure 3 5 W C 3 5 W C 3 5 W C 3 5 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 10 5 10 5 Minimum 5 5 5 5 Shipping Weight 27 lbs 27 lbs 29 lbs 29 lbs For the purpose of inpu...

Страница 31: ...8809 1 800 755 8809 www njplaza com ecep 21st Century 2950 Fretz Valley Road Perkasie PA 18944 4034 215 795 0400 800 325 4828 Laporte s Parts Service 2444 N 5th Street Hartsville SC 29550 7704 843 332...

Страница 32: ...3101 01E 32 3 2 18 20 21 19 12 8 9 10 22 19 7 14 6 22 22 17 5 20 15 16 11 13 1 4 Illustrated Parts Breakdown Variable Manually Controlled Winchester Oak Models CGS2718NA CGS2718PA CGS3124NA CGS3124PA...

Страница 33: ...6 19 Burner Orifice Injector 1 12 111124 01 111124 01 111124 01 111124 01 Burner Retainer Spring 1 13 102963 02 102963 02 102773 03 102773 03 Burner 1 14 102568 07 102568 08 102568 07 102568 08 Contro...

Страница 34: ...13101 01E 34 ILLUSTRATED PARTS BREAKDOWN Thermostatically Controlled Royal english oak Models CLD3924NTB CLD3924PTB CLD3018NTA CLD3018PTA 15 21 19 20 23 13 12 8 14 10 9 22 11 24 16 22 17 22 22 25 18 2...

Страница 35: ...099056 18 099056 19 Burner Orifice Injector 1 13 111124 01 111124 01 111124 01 111124 01 Burner Retainer Spring 1 14 102772 01 102772 01 102980 01 102980 01 Burner 1 15 101329 20 101329 19 101329 21...

Страница 36: ...e with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become da...

Отзывы: