SPEcIFIcAtIONS
18" Model
18" Model
24" Model
24" Model
(CGS2718PA)
(CLD3018PTA)
(CGS3124PA)
(CLD3924PTB)
(SGS3124PA)
Btu (Variable)
16,000/27,000
18,000/30,000
16,000/31,500
20,000/39,000
Type Gas
Propane/LP
Propane/LP
Propane/LP
Propane/LP
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure
8.0" W.C.
8.0" W.C.
8.0" W.C.
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
14"
14"
14"
Minimum*
11"
11"
11"
11"
Shipping Weight
27 lbs.
27 lbs.
29lbs.
27 lbs.
* For the purpose of input adjustment
18" Model
18" Model
24" Model
24" Model
(CGS2718NA)
(CLD3018NTA)
(CGS3124NA)
(CLD3924NTB)
(SGS3124NA)
Btu (Variable)
16,000/27,000
18,000/30,000
16,000/31,500
20,000/39,000
Type Gas
Natural Gas
Natural Gas
Natural Gas
Natural Gas
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure
3.5" W.C.
3.5" W.C.
3.5" W.C.
3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
10.5"
10.5"
10.5"
Minimum*
5"
5"
5"
5"
Shipping Weight
27 lbs.
27 lbs.
29 lbs.
29 lbs
* For the purpose of input adjustment
4. The mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capil-
lary at the bottom (see Figure 40). Slide the
thermostat sensing bulb into the clip.
IMPORTANT:
Do not crimp capillary.
OPtIONAL POSItIONING
OF tHERMOStAt
SENSING bULb
Continued
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-
backed
Mounting Clip
Figure 40 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom