![Desa CGESS Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/desa/cgess/cgess_safety-and-operation-manual_2486495004.webp)
www.desatech.com
117889-01B
4
GROUNDING
INSTRUCTIONS
This stove is for use on 120 volts. The cord has a
plug as shown in Figure 2. An adapter is available
for connecting three-blade grounding-type plugs
to two-slot receptacles. The green grounding lug
extending from the adapter must be connected to
a permanent ground such as a properly grounded
outlet box. The adapter should not be used if a
three-slot grounded receptacle is available.
Figure 2 - Grounding Methods
Figure 3 - Electric Stove Control Panel
OPERATING
INSTRUCTIONS
Once the unit has been properly connected to a
ground electrical outlet, it is ready to operate.
Note:
Ensure the circuit breakers for power
supply are turned on.
CONTROL PANEL OPERATION
Controls are located on the back of the unit near
the top (see Figure 3).
1. Main ON/OFF power switch: This switch is
located at the furthest right corner on the
control panel when looking at the back of
the unit. Turn the switch to ON and unit
will be ready to operate. The "|" indicates
ON and "O" indicates OFF.
2. Flame ON/OFF Switch: This switch is
located in the middle between the Main
ON/OFF switch and the Heater ON/OFF
switch on the control panel when looking at
the back of the unit. Turn the switch to ON
and the flame effect will turn on. The "|"
indicates ON and the "O" indicates OFF.
3. Heater ON/OFF Switch: This switch is
located to the left of the Flame ON/OFF
switch on the control panel. It has a symbol
of the sun directly below it.
4. Thermostat Control Dial: This dial is located
at the furthest left corner on the control panel.
It has a symbol of a thermostat directly below
it. Turn the dial clockwise past the number 8.
Built-In
Thermostat
Main Power
Switch
Flame Switch
Heater Switch
Grounding Pin
Adapter
You should hear a small clicking sound indicat-
ing the heater has started and heat will emit
from the vents at the top of the unit from the
front. To turn off heater, turn the dial counter
clockwise past number 1 and turn the Heater
Switch to OFF position. To increase the desired
temperature, turn the dial clockwise towards
Number 9.
CLEANING AND
MAINTENANCE
WARNING: Always discon-
nect power and allow the heater
to cool before performing any
cleaning, maintenance or reloca-
tion of this heater. Turn controls
to OFF and remove plug from
outlet or turn off circuit breaker
to heater.
Turn off heater and circuit breaker to heater before
performing any cleaning and/or maintenance. Al-
low heater to cool completely.
BULB REPLACEMENT
WARNING: The halogen light
bulbs in your unit can become
extremely hot. Allow at least 10
minutes between turning off the
heater and removing the light
bulbs to avoid accidental burns.
There are a total of 4 ( halogen light bulbs (type
GX6.35 rated 120 volts, 35 watts) in your unit.
• 1 bulbs provide illumination for the ember bed
beneath the log set
• 1 bulbs provide illumination for the flame
generation assembly
• 2 bulbs for replacement