6.  With control knob pressed in, press and 

release ignitor button. This will light pilot. 

The pilot is attached to the front burner. If 

needed, keep pressing ignitor button until 

pilot lights.

 

Note:

 If pilot does not stay lit, refer to 

Troubleshooting

, page 30. Also, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

7.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

 

Note:

 

If  pilot  goes  out,  repeat  steps  3 

through 7. This fireplace has a safety inter

-

lock system. Wait one (1) minute for system 

to reset before lighting pilot again.

8.  Turn control knob counterclockwise  

 

to desired heating level. The burner should 

light. Set control knob to any heat level 

between HI and LO.

 CAUTION: Do not try to ad-

just heating levels by using the 

equipment shutoff valve.

opERaTiNG FiREplaCE

Continued

Figure 43 -Propane/LP Gas Pilot 

Thermocouple

Ignitor 
Electrode

Pilot Burner

Thermocouple

Ignitor 
Electrode

Pilot Burner

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Fireplace

1.  Turn control knob clockwise 

 to the 

OFF position.

2. 

Turn off all electric power to the appliance (if 

applicable) if service is to be performed.

Shutting Off Burners Only (pilot stays lit)

Turn  control  knob  clockwise 

  to  the 

PILOT position.

THERMOSTAT CONTROL 

OPERATION

The thermostat used on this fireplace senses the 

room temperature. At times the room may exceed 

the set temperature. If so, the burner will shut off. 

The burner will cycle back on when room tem-

perature drops below the set temperature. 

The control knob can be set to any heat level 

between HI and LO.

Note:

 The thermostat sensing bulb measures 

the air near the fireplace cabinet. This may 

not always agree with room temperature (de

-

pending on housing construction, installation 

location, room size, open air temperatures, 

etc.). Frequent use of your fireplace will let you 

determine your own comfort levels.

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 5 under 

Lighting 

Instructions

, page 22.

2.  With control knob pressed in, strike match. 

Hold match to pilot until pilot lights.

3.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control  knob.  Now  follow  step  8  under 

Lighting Instructions

, column 1. 

OPERATING 

BLOWER

This blower has three settings: ON, OFF, and 

AUTO. In the ON position, the blower will oper-

ate constantly. In the OFF position, the blower 

will not operate. In the AUTO position, the 

blower will start when the thermostat senses a 

sufficient increase in firebox temperature.

Note:

 Your fireplace and thermostat blower 

will not turn on and off at the same time. The 

fireplace may run for several minutes before the 

blower turns on. After the heater modulates to 

the pilot position, the blower will continue to 

run. The blower will shut off after the firebox 

temperature decreases.

Figure 42 - Natural Gas Pilot

Содержание CDCFNR

Страница 1: ...damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to ligh...

Страница 2: ...appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Table of Contents Safety Information 3 Product Identification 4 Op...

Страница 3: ...sand orgenerateschemicals known to the State of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assembl...

Страница 4: ...uld occur due to log curing and fireplace burning manufacturing residues 8 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 28 9 Before using furniture polish w...

Страница 5: ...s to light fireplace Thermostatic Heat Control for thermostat Controlled Models Thermostat Controlled models have a thermostat sensing bulb and a control valve The thermostat will automatically modula...

Страница 6: ...4 Tighten screws firmly Figure 3 Removing and Installing Screen Screen Shoulder Screw Figure 4 Assembling Hood Hood Sheet Metal Screws Firebox Top Louver Air for Combustion and Ventilation WARNING Th...

Страница 7: ...d in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that sp...

Страница 8: ...ction5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space...

Страница 9: ...ng the full width and depth of the fireplace Use the dimensions shown for rough openings to create the easiest installation see Built In Fire place Installation page 10 CHECK GAS TYPE Use the correct...

Страница 10: ...wheremoving vehicle will not hit it For convenience and efficiency install fireplace where there is easy access for operation inspec tion and service in coldest part of room An optional blower kit is...

Страница 11: ...Wood Screws Wall Studs Note Aqualified installer should make all electri cal connections 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed...

Страница 12: ...e Installing Optional Blower Accessory GA3450TA page 13 1 Assemble cabinet mantel as shown in acces sory instruction sheet 2 If blower is installed install a properly grounded 120 volt three prong ele...

Страница 13: ...gn shim under adjusting plate as shown in Figure 15 4 Slide one end of adjusting plate shim in slot on mitered edge of top brass trim see Figure 15 5 Slide other end of adjusting plate shim in slot on...

Страница 14: ...ring Diagram For Blower Accessory Standard Installation Red Red Fan Switch Auto Off On Blue Blue Thermostat Switch N O Green White Green White On 110 115 V A C Blower Motor Black Off 1 2 3 Auto Remote...

Страница 15: ...Set cable bundle between the remote blower bracket and outer casing away from the burner 5 Test to make sure blower is working properly 6 Reinstall upper louver beginning with bottom screws see Figur...

Страница 16: ...TO GAS SUPPLY WARNING This appliance requires a 45 male flare fitting 5 8 18 UNF Unified National Fine Thread inlet connection and the flexible gas line provided WARNING A qualified service person mus...

Страница 17: ...tly to male threads of gas connector attached to flex ible gas line equipment shutoff valve see Figure 25 CAUTION Avoid damage to regulator Holdgasregulatorwith wrenchwhenconnectingittogas piping and...

Страница 18: ...opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoffvalvefornaturalgasorpropane LPsup ply to equipment sh...

Страница 19: ...Disconnecting Wires From Control Valve Figure 30 Attaching Battery to Receiver Battery Clip 9 Volt Battery Receiver Terminal Wires Figure 31 Installing Remote Receiver Remote Receiver White Wire to T...

Страница 20: ...stat has been electroni cally calibrated at the factory No adjustment or leveling is necessary Figure 34 Back View of Thermostat Base Feed wires through rectangular slots W R Figure 35 Thermostat Base...

Страница 21: ...ward 3 Install left and right brick liners using brackets and screws from hardware kit as shown in Fig ure 38 Screw the bracket into top of firebox and against brick liners Adjust bracket before tight...

Страница 22: ...BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which mus...

Страница 23: ...LOT position THERMOSTAT CONTROL OPERATION The thermostat used on this fireplace senses the roomtemperature Attimestheroommayexceed thesettemperature Ifso theburnerwillshutoff The burner will cycle bac...

Страница 24: ...part has been underwater Immediatelycallaqualifiedser vicetechniciantoinspecttheapplianceandto replaceanypartofthecontrolsystemandany gas control which has been under water LIGHTING INSTRUCTIONS WARN...

Страница 25: ...clockwise to the OFF position 2 If Using Optional Hand Held Remote Set selector switch in the OFF position to prevent draining battery Shutting Off Burners Only pilot stays lit You may shut off the bu...

Страница 26: ...and Off Thermostat Series Model HRC200 Series The hand held remote can be operated using either the manual mode MANU or thermo static mode AUTO see Figure 50 To select Fahrenheit Centigrade mode displ...

Страница 27: ...m temperature for a minimum of 30 minutes for proper operation See installation instructions on page 19 optional GWMS2 Wall Mounted SWITCH MakesuretheheaterswitchisonAUTO Thiswall switchworksjustliket...

Страница 28: ...son Fireplace may need more frequent cleaning due to excessive lint from carpeting pet hair bedding material etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooti...

Страница 29: ...from where the pilot flame comes out of the pilot assembly see Figures 57 or 58 depend ing on model With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw...

Страница 30: ...PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor ca...

Страница 31: ...ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natur...

Страница 32: ...knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installa tion clearances see page...

Страница 33: ...e Warning state ment at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning state ment at top of page 2 Control valve defective...

Страница 34: ...10 5 Minimum 5 Dimensions H x W x D including hood and screws 25 7 8 x 26 13 16 x 15 5 16 For purpose of input adjustment Remote Ready Models VDCFRP FDCFRP CDCFPR Rating 17 000 26 000 Btu Hr Gas Type...

Страница 35: ...placement Parts Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If t...

Страница 36: ...19 19 19 19 19 19 19 1 9 9 10 10 10 16 17 10 10 14 6 3 11 12 13 11 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 Illustrated Parts Breakdown firebox Models CDCFTNA CDCFTPA VDCFTN VDCFTP FDCFTN FDCFT...

Страница 37: ...rebox Wrapper 1 7 110339 01CK Outer Base 1 8 102635 02 Front Left and Right Sides 2 9 103209 01 Extruded Louver 2 103209 05 Extruded Louver 2 10 098304 01 Screw PPH AB 10 16 x 0 38 8 11 M10908 2 Screw...

Страница 38: ...111244 01G 38 Illustrated Parts Breakdown firebox Models CDCFNR and CDCFPR 8 10 8 14 14 14 14 14 14 14 1 9 9 10 10 20 21 22 10 16 17 10 10 6 3 11 12 13 23 19 24 11 15 16 18 16 16 16 16 16 16 16 2 5 16...

Страница 39: ...8 102635 02 Front Left and Right Sides 2 9 103209 05 Extruded Louver 2 10 098304 01 Screw PPH AB 10 16 x 0 38 12 11 M10908 2 Screw SLTD HWH TPG 6 32 x 0 38 4 12 104313 01 Right Pin Hinge 1 13 104313...

Страница 40: ...www desatech com 111244 01G 40 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS FDCFTP FDCFTN VDCFTP VDCFTN CDCFTPA and CDCFTNA 8 7 5 6 6 12 2 4 19 18 15 16 9 9 17 11 14 3 13 20 9 1 21 10...

Страница 41: ...15 098522 13 Thermostat Gas Valve LP 1 098522 12 Thermostat Gas Valve NG 1 16 101381 01 Valve Cover with Piezo 1 17 101628 03 Flexible Connector 1 18 099211 01 Screw HWH AB 10 16 x 2 50 2 19 098544 0...

Страница 42: ...RATED PARTS BREAKDOWN REMOTE READY MODELS FDCFRN FDCFRP VDCFRN VDCFRP CDCFNR and CDCFPR O F F P I L O T O N H I L O 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 FDCFTN TP VDCFRN RP...

Страница 43: ...DS Nut 2 9 M11084 26 Screw HWH AB 10 16 x 0 38 10 10 Chamber Floor 1 11 110793 01 Piezo Bracket 1 12 102445 01 Piezo Ignitor with Palnut Fastener 1 13 101628 01 Flexible Connector 1 14 098271 10 Ignit...

Страница 44: ...dges of wall opening Included with all mantels THERMOSTAT CONTROLLED BLOWER KIT GA3450TA For all models Provides better heat distribution Makes fireplace more efficient Automatically turns off and on...

Страница 45: ...fire place to be operated in a manually or thermostati cally controlled mode You can turn the fireplace on and off without ever leaving the comfort of your easy chair A wall mount docking station is i...

Страница 46: ..._____________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________...

Страница 47: ..._____________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________...

Страница 48: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 111244 01 Rev G 01 06 NOT A UPC 111244 01...

Отзывы: