111916-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
14
WARNING: The conversion kit must be installed
by a qualified service technician in accordance with
the manufacturers instructions and all applicable
codes and requirements of the authority having juris-
diction. If any information is these instructions is not
followed correctly, a fire, explosion or production of
carbon monoxide may result causing property dam-
age, personal injury or loss of life. The qualified
service technician is responsible for the proper in-
stallation of this conversion kit.
Figure 36- Installing New Parts for Gas Control Valve Conversion
CONVERTING FIREPLACE
FROM NATURAL GAS TO
PROPANE/LP GAS
Continued
HI
LO
O
FF
PIL
O
T
ON
Mounting
Screws
Rubber
Gasket
Identification Label
CONVERTING CONTROL VALVE
Convert the gas control valve by swapping out the valve regulator
portion of the gas valve.
1.
Using a TORX T20 or a slotted screwdriver, remove and dis-
card the three mounting screws, pressure regulator tower, and
diaphragm/spring components (see Figure 35).
2.
Insure that the rubber gasket is properly positioned on the new
pressure regulator assembly. Install new pressure regulator as-
sembly to valve using new mounting screws supplied with kit.
Tighten screws securely (approximately 25 in/lb). See Figure 36.
Figure 35 - Removing Parts for Gas Control Valve Conversion
HI
LO
O
FF
PIL
O
T
O
N
Pressure
Regulator
Tower
Mounting
Screws
Diaphragm/
Spring
Components
3.
Install the identification label enclosed with gas valve regulator
to the valve body where it can easily be seen (see Figure 36).
CONVERTING FIREPLACE FROM NATURAL GAS TO PROPANE/LP GAS
Converting Control Valve