background image

LIMITED WARRANTY

BLUE-FLAME VENT-FREE NATURAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for one (1) year from
the date of first purchase, provided that the product has been properly installed, operated and maintained in
accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to
restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized
Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA
International who will provide original factory replacement parts. Failure to use original factory replacement parts
voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and
instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that
fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper
installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a
defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1)
YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY
LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE
LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental
or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may
not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

Model

Serial No.

Date Purchased

WARRANTY INFORMATION

KEEP THIS WARRANTY

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.

099569-01
REV. E
5/94

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

INTERNATIONAL

Содержание BLUE-FLAME

Страница 1: ...age personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light an...

Страница 2: ...d those at high altitudes Natural Gas Natural gas is odorless An odor making agent is added to natural gas The odor helps you detect a natural gas leak However the odor added to natural gas can fade N...

Страница 3: ...fresh air is available See Fresh Air for Combus tion and Ventilation pages 5 through 8 6 Never run heater in small closed room Open door into next room to help ventilate 7 If heater shuts off do not r...

Страница 4: ...om carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES S...

Страница 5: ...The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unus...

Страница 6: ...r Gas furnace ___________________ BTU Hr Vented gas heater ___________________ BTU Hr Gas fireplace logs ___________________ BTU Hr Other gas appliances ___________________ BTU Hr Total ______________...

Страница 7: ...or on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 WARNING ICON G 001 WARNING Rework worksheet adding the space of...

Страница 8: ...en to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation gr...

Страница 9: ...re 4 page 10 If you can provide greater clearances from floor ceiling and joining wall You can locate heater on floor away from a wall An optional floor mounting stand is needed Purchase the floor mou...

Страница 10: ...b to back of heater for proper operation Attaching Thermostat Sensing Bulb 1 Remove thermostat sensing bulb from holders inside heater Route through slot opening in bottom of heater 2 Place clamp on t...

Страница 11: ...ongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or t...

Страница 12: ...n each end of bracket with holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to wall...

Страница 13: ...s 1 Locate two bottom mounting holes These holes are near bottom on back panel of heater see Figure 12 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mount...

Страница 14: ...nt trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed w...

Страница 15: ...lation or servicing Correct all leaks at once Continued Manual Shutoff Valve CONNECTING TO GAS SUPPLY Continued 3 Minimum From Gas Meter 4 W C to 10 5 W C Pressure WARNING ICON G 001 WARNING Never use...

Страница 16: ...ual shutoff valve see Figure 14 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from manual shutoff valve to thermostat...

Страница 17: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result i...

Страница 18: ...ront of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 24 through 27 Also...

Страница 19: ...flame height At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be...

Страница 20: ...h in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may...

Страница 21: ...needed keep pressing ignitor button until pilot lights Note If pilot does not light refer to Troubleshooting pages 24 through 27 Also contact a qualified service person or gas supplier for repairs Unt...

Страница 22: ...match Hold match to pilot until pilot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob 5 Replace front panel TO TURN OFF GAS TO APPLIANCE...

Страница 23: ...Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Figure 22 Correct Burner Flame Pattern Figure 23 Incorrec...

Страница 24: ...cessive lint from carpeting bedding material etc WARNING ICON G 001 WARNING Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater WA...

Страница 25: ...ntrol valve OBSERVED PROBLEM When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released POSSIBLE CAUSE 1 Gas supply tu...

Страница 26: ...clean burner see Cleaning and Mainte nance page 24 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate...

Страница 27: ...OBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF positi...

Страница 28: ...3 5 x 18 5 x 8 0 23 5 x 25 9 x 8 0 Carton 25 8 x 21 3 x 10 1 25 8 x 28 7 x 10 1 Weight pounds Heater 22 30 Shipping 27 35 SPECIFICATIONS SERVICE HINTS When gas pressure is too low pilot will not stay...

Страница 29: ...ter the replacement part number These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories PARTS CENTR...

Страница 30: ...ite to the address listed on the back page of this manual MANUAL SHUTOFF VALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND 18 000 BTU Hr Models GA4000B 28 000 BTU...

Страница 31: ...31 099569 ILLUSTRATED PARTS LIST Manual Control 18 000 BTU Hr Non Thermostat Model Parts list on page 33 12 ODS Pilot Assembly Parts list on page 33 26 24 34 19 29 33 20 12 1 12 2...

Страница 32: ...32 099569 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 30 31 32 18 NOTE Thermostat Gas Valve Shown See page 31 for Manual Control Valve...

Страница 33: ...1 Thermocouple 1 12 2 098515 01 098515 01 098515 01 Ignitor Electrode 1 13 099120 02 099120 02 099126 02 Burner 1 14 098517 01 098517 01 098517 01 3 16 Pilot Tubing 1 15 098251 02 098251 02 098251 04...

Страница 34: ...34 099569 NOTES...

Страница 35: ...35 099569 NOTES...

Страница 36: ...ransportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS TH...

Отзывы: