16
099569
ON
POSITION
OFF
POSITION
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 14).
2. Pressurize supply piping system by either using compressed air or opening main
gas valve located on or near gas meter.
3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply
mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open manual shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (thermostat
models) or control valve (non-thermostat model) (see Figure 15). Apply mixture
of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 17 through 22). Check the rest of the
internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 19 [thermostat models]
or page 22 [non-thermostat model]).
8. Replace front panel.
Figure 14 - Manual Shutoff Valve
Manual
Shutoff
Valve
Open
Closed
Thermostat Gas Valve or
Control Valve Location
Gas Meter
Figure 15 - Checking Gas Joints
CHECKING
GAS
CONNECTIONS
Continued
Manual
Shutoff
Valve
Содержание BLUE-FLAME
Страница 34: ...34 099569 NOTES...
Страница 35: ...35 099569 NOTES...