background image

115425-01

3

3

For  more information, visit www.desatech.com

SAFETY INFORMATION

PRODUCT IDENTIFICATION

LOCAL CODES

UNPACKING

PRODUCT IDENTIFICATION

Figure 1 - Product Identifi cation (Ramp Pan Burner)

Hearth Kit Model _________________________

Serial Number ___________________________

Log Set Model ___________________________

SAFETY INFORMATION

Continued

Grate

Burner 

Pan

Burner Inlet 
(Under Pan)

UNPACKING

 CAUTION: Do not remove the data plates from 

the burner pan. The data plates contain important 
product information.

1. 

Remove logs, hearth kit, pan materials, and hardware from car-
ton.

2.  Remove all protective packaging applied to logs and base for 

shipment.

3.  Check all items for any shipping damage. If damaged, promptly 

inform dealer where you bought the product.

LOCAL CODES

Install and use log set with care. Follow all local codes. In the 
absence of local codes, use the latest edition of The National Fuel 
Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

10. The installation and provisions for combustion and ventilation air 

must conform with the 

National Fuel Gas Code, ANSI Z233.1/

NFPA 54, Section 5.3, Air for Combustion and Ventilation

.

11

.  Do not run log set

• where fl ammable liquids or vapors are used or stored
•  under dusty conditions

12. Do not burn solid fuel in the fi replace after installing the log set. Do 

not use this log set to cook food or burn paper or other objects.

13. Log set becomes very hot when in use. Keep children and adults 

away from hot surface to avoid burns or clothing ignition. Log 
set will remain hot for a time after shutdown. Allow surface to 
cool before touching.

14.  Carefully supervise young children when they are in the room 

with log set. 

15.  To help prevent breakage, new logs must be broken-in (see 

Curing Logs page 10).

16. Turn log set off and let cool before servicing, installing, or re-

pairing. Only a qualifi ed service person should install, service, 
or repair log set. 

17.  Provide adequate clearances around air openings.

Содержание BCS18, BCS24, BCS30

Страница 1: ...ocedures For as sistance or additional information consultaquali edinstaller service agency or the gas supplier WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 fac...

Страница 2: ...set in a recreational vehicle where curtains furniture clothing or other ammable ob jects are less than 42 inches from the front top or sides of the log set in high traf c areas in windy or drafty are...

Страница 3: ...Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 10 Theinstallationandprovisionsforco...

Страница 4: ...liance must be installed only in a solid fuel burning replace with a working ue and constructed of noncom bustible material The charts in Figure 2 indicate technical information regarding the installa...

Страница 5: ...rap where it is within reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and c...

Страница 6: ...nce WARNING Never use an open ame to check for a leak Apply a noncorrosive leak detection uid to all joints Bubbles forming show a leak Correct all leaks at once CHECKING GAS CONNECTIONS Pressure Test...

Страница 7: ...are clear and producing ame evenly across the burner If any ports ap pear blocked clear them by removing the burner manifold and reaming the ports with a modi ed paper clip or other suitable tool 5 Wh...

Страница 8: ...s about installation operation or troubleshooting If so contact DESA s Technical Service Depart ment at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You c...

Страница 9: ...y true with propane LP gas Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner ame is too low or too high 1 Contact local natural or...

Страница 10: ...eak See Warning statement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob...

Страница 11: ...Use for additional decoration only 3 pine cones per box ASH BED MATERIAL Vermiculite GA9750A Not Shown For all models Use for rebox decoration only GLOWING EMBERS GA9950A Not Shown For all models Use...

Страница 12: ...www desatech com ILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWN Models PHK 18 24 30 BCS18 24 30 Models PHK 18 24 30 BCS18 24 30 Number and style of logs vary by model 1 3 2 4 5 6 9 8 19 18 1...

Страница 13: ...538 14538 Venturi 1 6 14527 14527 14527 Venturi Gasket 1 7 115482 01 115482 02 115482 03P Burner Pan 1 8 901242 01 901242 01 901242 01 Damper Clamp Std Assy 1 9 11209 11209 11209 Nut 10 24 2 10 114986...

Страница 14: ...leted Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to...

Страница 15: ...115425 01 15 15 For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 16: ...tive log set will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDESANYANDALL OTHER EXPRES...

Отзывы: