background image

9

104192

OWNER’S MANUAL

SERVICE
PROCEDURES

Continued

Figure 12 - Removing Air and Fuel Line
Hoses

Nozzle/
Adapter
Assembly

Combustion
Chamber

Figure 13 - Removing Nozzle/Adapter
Assembly

Nozzle Face

Nozzle

Nozzle
Seal

Nozzle

Adapter

Air Line
Fitting

Fuel Line

Fitting

Figure 14 - Nozzle and Nozzle Adapter

NOZZLE ASSEMBLY

1.

Remove upper shell (see page 7).

2.

Remove fan (see page 7).

3.

Remove fuel and air line hoses from
nozzle assembly (see Figure 12).

4.

Turn nozzle assembly 1/4 turn to left
and pull toward motor to remove (see
Figure 13).

5.

Place plastic hex-body into vise and
lightly tighten.

6.

Carefully remove nozzle from the
nozzle adapter using 5/8" socket wrench
(see Figure 14).

7.

Blow compressed air through face of
nozzle. This will free any dirt in nozzle area.

8.

Inspect nozzle seal for damage.

9.

Replace nozzle into nozzle adapter un-
til nozzle seats. Tighten 1/3 turn more
using 5/8" socket wrench (40-45 inch-
pounds). See Figure 14.

10. Attach nozzle assembly to burner strap.
11. Attach fuel and airline hoses to nozzle

assembly. See Fuel and Air Line Re-
placement and Proper Routing
.

12. Replace fan (see page 7).
13. Replace fan guard and upper shell (see

page 7).

Fuel Line
Hose

Nozzle/
Adapter
Assembly

Combustion
Chamber

Air Line
Hose

Burner
Strap

Photocell
Bracket

FUEL AND AIR LINE
REPLACEMENT AND
PROPER ROUTING

1.

Remove upper shell (see page 7).

2.

Remove side cover screws using 5/16"
nut driver.

3.

Remove side cover.

4.

Inspect fuel and air line hoses for cracks
and/or holes. If fuel line hose is dam-
aged, disconnect from nozzle adapter
(see Figure 12) and from fuel filter (see
page 8). If air line hose is damaged, dis-
connect from nozzle adapter (see Fig-
ure 12) and from barb fitting on pump
end cover (see Figure 15).

5.

Install new air and/or fuel line. Attach
one end of air line hose to barb fitting
on pump end cover (see Figure 15) and
the other end to nozzle adapter (see Fig-
ure 12). Attach one end of fuel line hose
to fuel filter (see page 8) and the other
end to nozzle adapter (see Figure 12).
Route air and fuel line approximately
as shown in Figure 12.

Note:

 Hoses are not to be touching pho-

tocell bracket.

6.

Replace side cover.

7.

Replace upper shell and fan guard (see
page 7).

Figure 15 - Air Hose to Barb Fitting

Barb Fitting

Air Hose

Pump End Cover

Continued

Содержание ARL B110BT

Страница 1: ... S MANUAL IMPORTANT Read and understand this manual before assembling start ing or servicing heater Improper use of heater can cause serious injury Keep this manual for future reference Heater Size 110 000 Btu Hr Models B110BT R110BT and REM110BT H S I Series ...

Страница 2: ...ed by a fire at lower elevation h Fuel storage shall be in accordance with the federal state or local author ity having jurisdiction Never use heater where gasoline paint thinner or other highly flammable va pors are present Follow all local ordinances and codes when using heater Heaters used in the vicinity of tarpau lins canvas or similar enclosure mate rials shall be located a safe distance fro...

Страница 3: ...ly tap with hammer to secure 3 Place heater on wheel support frame Make sure air inlet end rear of heater is over wheels Line up holes on fuel tank flangewithholesonwheelsupportframe 4 Placefronthandle andrearhandleifpro vided on top of fuel tank flange Insert screwsthroughhandle s fueltankflange and wheel support frame Attach nut finger tight after each screw is inserted 5 After all screws are in...

Страница 4: ...ly flammable fuels VENTILATION Figure 3 Cross Section Operational View Clean Heated Air Out The Fuel System The air pump forces air through the air line The air is then pushed through the nozzle This air causes fuel to lift from the tank A fine mist of fuel is sprayed into the combustion chamber The Air System The motor turns the fan The fan pushes air into and around the Fuel Filter Air Line To B...

Страница 5: ... ate this heater Follow all local codes when using this heater STORING TRANSPORTING OR SHIPPING Note If shipping transport companies re quire fuel tanks to be empty 1 Drain fuel tank Note This model has a drain plug on underside of fuel tank Remove drain plug to drain all fuel Be sure all fuel is removed 2 Replace drain plug PREVENTATIVE MAINTENANCE SCHEDULE WARNING Neverserviceheaterwhile it is p...

Страница 6: ...seeing the flame 6 Dirty photocell lens 7 Bad electrical connection between pho tocell and ignition control assembly 8 Defective photocell 9 Defective ignition control assembly REMEDY 1 Check circuit breaker in electrical panel 2 Turn thermostat knob to a higher setting 3 Check all electrical connections See Wiring Diagram page 11 4 See Ignition Control Assembly page 10 5 If fan does not turn free...

Страница 7: ... Tighten setscrew firmly 40 50 inch pounds 8 Replace fan guard and upper shell AIR OUTPUT AIR INTAKE AND LINT FILTERS 1 Remove upper shell see Upper Shell Removal column 1 2 Remove filter end cover screws using 5 16 nut driver 3 Remove filter end cover 4 Replace air output and lint filters 5 Wash or replace air intake filter see Preventative Maintenance Schedule page 5 6 Replace filter end cover 7...

Страница 8: ...bracket on top see Figure 11 7 Remove ignitor screw with a 1 4 nut driver Carefully remove ignitor from nozzle adapter bracket 8 Carefully remove replacement ignitor from styrofoam packing 9 Carefully guide ignitor into opening in nozzle adapter bracket Do not strike ignitor element Attach ignitor to nozzle adapter bracket with screw using a 1 4 nut driver see Figure 11 Torque 8 to 15 in lbs Do no...

Страница 9: ...e Fuel and Air Line Re placement and Proper Routing 12 Replace fan see page 7 13 Replace fan guard and upper shell see page 7 Fuel Line Hose Nozzle Adapter Assembly Combustion Chamber Air Line Hose Burner Strap Photocell Bracket FUEL AND AIR LINE REPLACEMENT AND PROPER ROUTING 1 Remove upper shell see page 7 2 Remove side cover screws using 5 16 nut driver 3 Remove side cover 4 Inspect fuel and ai...

Страница 10: ...o 003 004 if needed see Figure 17 Note Rotate rotor one full turn to in sure the gap is 003 004 at tightest position Adjust if needed 10 Install blades pump plate air filters and filter end cover 11 Replace fan guard and upper shell 12 Adjust pump pressure see page 7 Note If rotor is still binding proceed as follows 13 Perform steps 1 through 6 above 14 Place fine grade sandpaper 600 grit on flat ...

Страница 11: ...or No 1 Fuel Oil Fuel Tank Capacity U S Gal 9 0 Fuel Consumption Gal Per Hr 8 Electric Requirements 120 V 60 Hz Amperage Normal Run 3 6 Hot Air Output CFM 490 Motor RPM 3440 Motor HP 1 5 Shipping Weight Approximate Pounds 58 Heater Weight without Fuel Approximate Pounds 49 Figure 20 Wiring Diagram WIRING DIAGRAM Blue Photocell Power Plug 120V 60Hz Ignitor Ignitor Blue White Red Yellow Yellow Green...

Страница 12: ...11 12 15 25 26 27 24 28 29 20 22 21 30 31 17 14 14 33 34 35 36 32 26 13 18 5 4 6 7 8 7 2 7 1 7 5 7 4 7 3 40 39 38 ILLUSTRATED PARTS BREAKDOWN B110BT R110BT REM110BT Motor and Pump Assembly 10 11 10 13 10 17 10 16 10 15 10 14 10 13 10 12 10 10 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 ...

Страница 13: ... M10993 1 Relief Spring 1 10 11 M27694 Adjusting Screw 1 10 12 M22997 Plug 1 10 13 M12461 31 Screw 10 32 x 1 10 10 14 M12244 1 Output Filter 1 10 15 M11637 Lint Filter 1 10 16 M50820 02 Barb Fitting 1 10 17 M8643 Blade 4 11 M50631 Rubber Bumper 2 12 101206 01 Motor Mounting Bracket 1 13 101695 01 Button Plug 1 14 104068 02 Ignition Control Assembly 1 15 NTC 4C Hex Lock Nut 1 4 20 2 16 M51114 01 Fa...

Страница 14: ... 2 if equipped 2 M12345 33 Screw 10 24 x 1 3 4 B110BT 8 REM110BT R110BT 6 3 M12342 3 Wheel Support Frame 1 4 NTC 3C Hex Nut 10 24 B110BT 8 REM110BT R110BT 6 5 097896 04 Wheel Master and Remington 2 097896 01 Wheel Reddy 2 6 M28526 Cap Nut 2 7 M51015 01 Axle 1 PART NUMBER DESCRIPTION QTY 100621 06 Thermostat Decal 1 PARTS LIST 5 7 6 PARTS AVAILABLE NOT SHOWN ...

Страница 15: ...art s call DESA International s Parts De partment at 1 800 972 7879 for referral in formation Parts Centrals are listed in the AuthorizedServiceCenterbookletsupplied with heater When calling DESA International have ready model number of your heater the replacement part number AIR GAUGE KIT HA1180 Special tool to check pump pressure A 008 IGNITION CONTROL ASSEMBLY PHOTOCELL TESTER HA1170 Special to...

Страница 16: ... This warranty is extended only to the original retail purchaser when proof of purchase is provided This warranty covers only the cost of parts and labor required to restore the product to proper operating condition Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty Warranty service is available only through authorized dealers and service ...