4
DERTEC Signature line SL3SS serie AC motoren
Open the cover of the junction box using an appropriate tool.
Prevent damage to the threads and O-ring.
Carefully remove the insulation from the earthing cable and get an
eye-type cable lug suitable for the cable used, with the corresponding
diameter. Fit the cable lug onto the earthing cable. Crimp the cable eye
to the earthing cable.
Connect the motor winding leads and the motor wires with suitable
crimp connections in accordance with the wiring diagram.
The same instructions apply for the built-in PTCs and bimetal thermal
protectors. Connect the earth wire to the earth connection in the motor.
The power cable must correspond with the size of the cable gland.It
must fit perfectly to ensure protection against moist.
Lightly grease the O-ring and blue hygiene ring. Grease the O-rings on
the central mounting pin. Place the terminal box cover over the central
mounting pin and make sure that the cable gland is positioned so that
the cable gland is facing down.Take the mounting bolt, grease the blue
sanitizer and place it around the mounting bolt.
Insert the mounting bolt into the center pin and tighten securely.
The O-rings offer sufficient protection against moisture penetration, the
blue hygiene rings ensure a hygienic seal.
Installation instructions