EX, SGX VIBRATOR MOTORS
Figure 3 RTV Sealant Application
Power Connector Style
1. Remove cover from motor junction box, and discard O-ring (Figure 4).
2. Insert motor cord leads through junction box cover.
3. Match leads to power connector markings, and connect leads to terminals as shown.
4. Apply anti-seize compound to front gland nut, and install and tighten in threaded opening in
cover.
5. Install remaining gland components, and tighten backnut only sufficiently to cause red seal to
begin to protrude. Do not over-tighten backnut.