Products Specification
Product Name: Air Humidifier
Product Model: M977
Capacity: 9.0L
Power: 26W
Voltage: 220-240V~50/60Hz
Mist: 300mL/H
Dimension: Approx. 216*216*699mm
Weight: Approx. 2.2kg
Packing List
Parts Name
Quantity
Air Humidifier
1
Instruction Manual
1
Warranty Card
1
Failure Analysis and Solutions
Mist knob is switch on, no wind and mist?
Cause: Power is not connected or there is a
problem on the power.
Solution: Reconnect power supply. If still unable
to function, kindly contact our customer service.
The light is on, but there is no wind and no
mist?
Cause: Lack of water
Solution: Fill water in water tank.
Mist volume is low
Cause: Atomizer plate is not clean or water is not
pure enough.
Solution: Clean the atomizer plate and replace
with clean water.
Mist leak from mist nozzle surrounding
Cause: There are gap between mist nozzle with
water tank.
Solution: Soak the mist nozzle in water and
replace back.
Product Instructions
1. Remove the humidifier from box and place on
a flat surface. Remove the
fill with water (do not exceed the max. water
level), place back the water tank cover and
connect the cable plug.
2. Press On/Off button, the machine will enter
default mode; the mist will be at highest level.
UV light on; water tank with blue light; the
screen showing current humidity level; other
function at standby mode.
3. Timer: Press “Timer
show the timer digit (adjust starting from 1 hour).
Each press will add 1 hour, able to set until 14
hours, then enter timer mode. When the operating
time reaches the time set, the machine will stop
operating (Note: the timer
4. UV Sterilization: After on the humidifie
machine will enter the UV
automatically. Press UV sterilization button to off
the UV mode.
5. Sleep: Press “Sleep
and water tank light will off after 5 seconds, but
other functions are operating as normal. Press any
button to dismiss sleep mode.
6. Humidity: Press
humidity level. The starting humidity is 55%RH.
Press one time to add 5% RH. (The humidity
level setting is from 30
preferred humidity level, the digit will bli
seconds and enter the humidity mode. The
humidity digit shown is current humidity level.
When the humidity reaches the set level, the mist
function will stop working. When the humidity is
lower 5%RH than the setting, the misting
function will start wo
Product Instructions
Remove the humidifier from box and place on
a flat surface. Remove the water tank cover and
fill with water (do not exceed the max. water
level), place back the water tank cover and
connect the cable plug.
Press On/Off button, the machine will enter
the mist will be at highest level.
on; water tank with blue light; the
screen showing current humidity level; other
function at standby mode.
imer” button, the screen will
show the timer digit (adjust starting from 1 hour).
press will add 1 hour, able to set until 14
hours, then enter timer mode. When the operating
time reaches the time set, the machine will stop
operating (Note: the timer digit is by countdown)
UV Sterilization: After on the humidifier, the
enter the UV sterilization mode
automatically. Press UV sterilization button to off
Sleep” button, the screen, digit
and water tank light will off after 5 seconds, but
other functions are operating as normal. Press any
to dismiss sleep mode.
Press “Humidity” button to adjust
level. The starting humidity is 55%RH.
Press one time to add 5% RH. (The humidity
level setting is from 30-95%RH). After set to the
preferred humidity level, the digit will blink 3
seconds and enter the humidity mode. The
humidity digit shown is current humidity level.
When the humidity reaches the set level, the mist
function will stop working. When the humidity is
lower 5%RH than the setting, the misting
will start working.
Product Instructions
7. Mist: The default mode as highest level mist
“
”, press one time to set middle mist
level “
”, press another time for lowest
level “
”.
8. Water tank light: The function as default mode,
the light will automatically off after the machine
is off.
9. Cover and main motor auto cut-off when lift
up: The machine will auto cut-off operation when
the cover and main motor is lift up.
10. Water shortage: When the water tank is lack
of water, the machine will stop operate, LED
panel will show red color at the water shortage
icon. Refill water and restart the machine.
Cleaning And Maintenance
Add detergent powder (for humidifier) with clean
water and soak as per detergent instructions. Use
a brush to scrub gently the atomizer and rinse
with clean water and leave it dry. Recommend to
clean humidifier regularly, once a week or every
2-3 days
if using essential oil or sanitizer.
Water Tank Cleaning
Remove the main motor, clean the water tank and
place back the main motor.
Upper Component Cleaning
Remove cover and middle board, clean the water
tank and place back all accessories.
7. Mist: The default mode as highest level mist
press one time to set middle mist
, press another time for lowest
8. Water tank light: The function as default mode,
the light will automatically off after the machine
off when lift
off operation when
When the water tank is lack
ne will stop operate, LED
will show red color at the water shortage
Add detergent powder (for humidifier) with clean
Use
inse
Recommend to
once a week or every
Remove the main motor, clean the water tank and
Remove cover and middle board, clean the water
Precautions
1. The power supply voltage must be consistent
with the rated power of this product.
2. This appliances is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
experience and knowledge, unless they have been
given supervision or instruction concerning use
of the appliance by a person responsible for their
safety.
3. Please use the product at normal room
temperature (5
°
C~40
°
C), humidity: <80%RH.
4. Please put and use the product on a flat surface.
5. Please do not use the humidifier directly on a
wooden floor, to prevent the floor from damage.
6. Please put the humidifier 2 meter away from
furniture & electronic devices, to prevent from
wet.
7. Please prevent the humidifier from heat and
direct sunlight.
8. Do not insert water higher than 40
°
C into the
water tank to prevent product from damage.
9. Do not allow water to flow from the air outlet
to the body. If there is, wipe it with dry cloth to
prevent damage to the machine.
10. If there is any abnormal sound or smell, turn
off the humidifier immediately.
11. Please do not insert any metal, chemical or
detergent to the water tank or base.
12. Turn off the power supply and unplug before
pouring the water from the water tank.
13. Do remember to off the power supply and
unplug if there is need to adjust, clean and add
water. Do not move the product when it is
working.
14. Strictly not allowed to insert water into the
mist nozzle and air outlet.
15. When cleaning, prevent the product from
water.
16. Do not simply disassemble the product.
17. To avoid growth of bacteria, do clean the
humidifier regularly.
18. This humidifier is for household use only.