5. MAINTENANCE SECTION 
 

 

 

 

Warning! 

Special  vacuum  maintenance  must  be carried  out  solely  by  specialised  technicians 

authorised by the DEPURECO dealer. 

 

 

 

5.1

 

    Informative notes 

 

This section describes the checks and routine maintenance operations required to ensure proper vacuum 

operation. 

 

Maximum  reliability  and  minimum  maintenance  costs  are  the  result  of  a  planned  maintenance  and 

inspection schedule carefully followed throughout the entire lifespan of the vacuum. 

Observe the set maintenance intervals and schedule the interventions according to specific requirements 

in relation with the vacuum production cycle. 

 

Always use perfectly working tools specifically intended for the operation to be carried out; the use of 

inadequate or inefficient tools can cause severe damages. 

 

Any other intervention required to remove faults or malfunctions must be expressly authorised by the 

manufacturer. 

In these cases, always communicate the vacuum identification data - see para. 1.4 of this manual. 

 

For significant repairs, refer to the authorised dealer, whose specialised personnel has the technological 

expertise and is always available for prompt interventions. 

 

For user maintenance operations, the vacuum must be disassembled, cleaned and maintained, where 

possible, in such a way as to prevent hazards to the maintenance personnel and to third parties. Suitable 

precautionary  measures  include  decontamination  before  dismantling,  measures  for  filtered  forced 

ventilation  of  the  room  where  the  appliance  is  disassembled,  cleaning  of  the  maintenance  area  and 

suitable personal protection equipment. 

 

Once every three months (or more frequently, according to the operating cycle and the conditions of use), 

the manufacturer or a qualified technician must check the filters, ensuring that they are not damaged; the 

tightness of the air system and proper operation of the control devices.  

 

Should maintenance operations or repairs be carried out, all contaminated objects must be adequately 

cleaned, placed in waterproof bags and disposed of in compliance with the regulations in force. 

 

 

 

 

 

 

 

Содержание M 100

Страница 1: ...INSTRUCTION AND MAINTENANCE MANUAL M SERIES...

Страница 2: ...y recommendations 13 2 3 Safety plates and symbols 15 2 4 Residual risks 16 2 5 Applied Directives 17 3 HANDLING UNPACKING AND INSTALLATION SECTION 3 1 Handling 18 3 2 Unpacking 19 3 3 Installation 21...

Страница 3: ...der for our customer to fully appreciate the quality of this machine Please read all sections before using the machine for the first time It includes information recommendations and important warnings...

Страница 4: ...sure limit value of 0 1 mg m3 on the basis of the occupied volume H High risk suitable to separate all dusts with all exposure limit values on the basis of the occupied volume including cancerogenic a...

Страница 5: ...expressly required by Machinery Directive 2006 42 EC and the technical data are taken from the technical file archived at DEPURECO With reference to Regulation 1907 2006 EC REACH DEPURECO hereby decl...

Страница 6: ...rts 1 Commands 2 Vacuum handle 3 JetClean valve 4 Filter chamber 5 Filter shaker handwheel 6 Suction inlet 7 JetClean sliding damper 8 Dust Debris Bin 9 Bin handle 10 Accessories Bin 1 2 3 4 5 6 8 9 1...

Страница 7: ...aler 1 6 Permitted Uses These vacuum cleaners are designed and built according to the 2006 42 CE Machine Directive for an exclusive professional industrial use either way for any non domestic use This...

Страница 8: ...t be clean and suitably lit 1 8 Noise level The phonometric tests performed on this specific vacuum cleaner model demonstrate a sound pressure level of M 65 100 M 100 Longopac M 65 100 JC M 100 JC Lon...

Страница 9: ...660 x 800 x 1300 1515 660 x 800 X 1515 660 x 800 x 1300 1515 660 x 800 X 1515 Voltage I Frequency V Hz 230 I 50 60 Power kW HP 3 9 5 2 Maximum vacuum mBar 250 Maximum air flow m h 570 M filter surfac...

Страница 10: ...e repair and must accompany the vacuum during its shipment Defects that are not evidently due to materials or manufacturing will be examined solely at our premises or at a Technical Service Centre of...

Страница 11: ...y occur Adequate training is crucial to this end DEPURECO shall not be held liable for accidents or damage due to the improper use of the vacuum by untrained personnel or to failure to comply even par...

Страница 12: ...electrical mains Plug the vacuum cleaner into a socket with a correctly installed ground contact connection Make sure that the vacuum cleaner is turned off The plugs and connectors of the connection...

Страница 13: ...luminium dusts etc To tamper with or modify the return valve set up by the manufacturer The use of the JETCLEAN system in the presence of potentially explosive clouds in the atmosphere To carry out ma...

Страница 14: ...d symbols Plates with safety symbols and or messages are applied to the vacuum and its packaging These pages show their precise location and the nature of the hazard Warning Ensure that all safety mes...

Страница 15: ...t use in presence of explosive and inflammable liquid substances The vacuum must not be used in environments containing liquid substances or liquids that can evaporate at room temperature inflammable...

Страница 16: ...30 EU Electromagnetic compatibility directive 2011 65 EU ROHS Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2014 35 UE Low tension dir...

Страница 17: ...oad 200 mm off the ground and swing backwards Always keep the height of the working environment in mind when lifting loads Before starting any movement ensure that the area is cleared and that there a...

Страница 18: ...Page 19 of 47 3 2 Unpacking Cut and unwind the two packaging fixing belts remove the staples that fix the carton packaging to the pallet with the aid of a screwdriver remove the carton completely...

Страница 19: ...brackets The cardboard packaging can be recycled To protect the environment make sure to dispose it off in specialised collection centres Warning Keep the pallet In the event of subsequent transport t...

Страница 20: ...ne or more components being damaged do not continue with installation inform DEPURECO about the anomaly and agree upon action to be taken The vacuum cleaner is already fitted with an appropriate filte...

Страница 21: ...wing operation must be carried out by a qualified electrician Ensure that the power supply line corresponds to the voltage and frequency indicated on the identification plate and that it is efficientl...

Страница 22: ...e vacuum must be adequately educated informed and trained in compliance with the occupational safety standards in force and during the various operations must wear personal protective equipment PPE su...

Страница 23: ...ac are located and blocked under the filtering chamber of the vacuum cleaner Secure the vacuum cleaner using the lever on the swivel caster as shown in the figure Warning Do not move the vacuum cleane...

Страница 24: ...hich indicates the vacuum level inside the vacuum cleaner If with the vacuum cleaner on and the suction inlet free the vacuum gauge shows the value reported in the table below the filter is clogged St...

Страница 25: ...lly stopped Lift and lower the lever vigorously to shake the inner filter Warning If the vacuum cleaner after cleaning the filter doesn t work correctly it s possible that the filter is clogged and mu...

Страница 26: ...ing to the dust becoming detached from the filtering fabric of the cartridge without needing to switch the vacuum cleaner off The system is made up of a disk lid on the filter chamber and a shutter si...

Страница 27: ...Page 28 of 47 Lower the shutter detail no 7 chap 1 2 and resume normal use Warning The JetClean cleaning system only works with the vacuum cleaner switched on...

Страница 28: ...bin to avoid filling it excessively Proceed as follows to empty the container Switch the machine off As previously mentioned the vacuum is blocked thanks to the brake on the pivoting wheel Unlock the...

Страница 29: ...for its replacement After having removed the bag tie it dispose of it and insert a new bag in the bin Warning If the bin weighs more than 15 Kg at least two people are needed to empty it Waste disposa...

Страница 30: ...eps below to insert and lock the container Place the bin under the vacuum s chamber Lower the lever blocking the container completely with both hands The pins A must be aligned with the slots B Warnin...

Страница 31: ...tween the two clamps Remove the portion of the sac containing the vacuumed material then pull the sac until it reaches the plate at the bottom of the vacuum cleaner to have another sac ready for use R...

Страница 32: ...vacuum off Rotate the red hooks under the filter chamber to unlock the sac s support ring Take the ring out and remove the last portion of the sac Position the sac inside the ring ensuring that both...

Страница 33: ...of the sac with the supplied clamp Switch the vacuum cleaner on and immediately assess its regular operation 4 9 Storage Decommissioning Remove the filter and clean it empty the refuse collection con...

Страница 34: ...te the vacuum identification data see para 1 4 of this manual For significant repairs refer to the authorised dealer whose specialised personnel has the technological expertise and is always available...

Страница 35: ...ous injury to personnel Maintenance operations must be carried out by trained technicians specialised in the following sectors Mechanical maintenance Electrical maintenance It is the Safety Manager s...

Страница 36: ...or on other electrical components must only be carried out by the specially trained electrical maintenance technician authorised by the Safety Manager Warning After any maintenance intervention the He...

Страница 37: ...the vacuum cleaner from the socket Remove the bin or the Longopac sac From the lower side of the filter chamber release the clip and remove the retaining pin of the cage from the filter shaking lever...

Страница 38: ...ter and place all components on a work bench Loosen the fastening clip H remove the filter from its support and using scissors cut the lower belts that clamp it to the filter s cage Remove the filter...

Страница 39: ...filtering chamber paying particular attention to the alignment of the cage with the filter shaker s handle Insert the lever s end into the appropriate seat on the bottom of the cag then insert the fas...

Страница 40: ...the applicable legislation on the type of material collected To reassemble the HEPA filter operate in reverse order Fit the new filter and screw it onto the holding cage by means of the screw previous...

Страница 41: ...ar values on the pressure gauge Clogged filter Shake the filter If this solution is not effective replace it Clogged hose Check the vacuum hose and clean it Dusts come out of the vacuum cleaner Pierce...

Страница 42: ...ectrical and electronic parts of this product must be disposed of in compliance with Italian Legislative Decree 151 2005 and subsequent amendments Directive 2002 96 EC on WEEE Waste Electrical and Ele...

Страница 43: ...MAINTENANCE LOG INTERVENTION 1 DATE TECHNICAL ASSISTANCE TYPE OF INTERVENTION INTERVENTION 2 DATE TECHNICAL ASSISTANCE TYPE OF INTERVENTION...

Страница 44: ...INTERVENTION 3 DATE TECHNICAL ASSISTANCE TYPE OF INTERVENTION INTERVENTION 4 DATE TECHNICAL ASSISTANCE TYPE OF INTERVENTION...