![Denyo DCA-10LSX Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/denyo/dca-10lsx/dca-10lsx_instruction-manual_2485059017.webp)
Indication/alarm lamp
(1) Preheat lamp
When the starter switch is set in the "PREHEAT" position,
this lamp goes on.
In a little time this lamp goes off, indicating that the machine
has been preheated to be ready for startup.
(2) Warning Lamps
This monitor indicates the following failures, if any one of
them occurs.
ф High jacket water temperature
This lamp goes on when the water temperature rises
abnormally.
If this lamp goes on during operation, the emergency stop
device immediately operates to shut down the engine
automatically.
(2) Oil pressure failure
If this machine is in normal operation, this lamp stays off.
When the starter switch is turned to "RUN" position to start
the engine, the lamp goes on, and when the oil pressure rises
after startup, it goes off.
If this lamp goes on during operation, the emergency stop
device immediately operates to shutdown the engine
automatically.
© Insufficient charge
This lamp goes on when the output voltage of the alternator
drops unusual value.
If this lamp goes on during operation, the emergency stop
device immediately operates to shutdown the engine
automatically.
13