Denver Instrument PK-10 Скачать руководство пользователя страница 2

You have purchased a quality precision weighing instrument that
requires handling with care. 

Read entire contents of this 

Operation Manual

prior to operating

your new Denver Instrument balance. 

Disclaimer Notice

Calibrate your balance using a reference weight of the appropriate
tolerance (class). An instrument can be no more accurate than the
standard to which it has been compared. For assistance in the selec-
tion of reference weights, please contact the factory.

Caution!

Changes or modifications not expressly approved by the manufac-
turer could void the user’s authority to operate this equipment.

Warning

Never lift balance by the weighing pan as this may cause

damage to internal mechanisms.

Always lift and transport the balance by its base, including

removal from packing materials!

!

!

Содержание PK-10

Страница 1: ...PK Series Operation Manual Memory Counting ozt dwt oz g Print T A R E Off On Mem ory Cal Mode PK 202 Max 20 0g d 0 01 g 902378 1 Rev B...

Страница 2: ...ss An instrument can be no more accurate than the standard to which it has been compared For assistance in the selec tion of reference weights please contact the factory Caution Changes or modificatio...

Страница 3: ...Operation 3 Calibration 4 Features 5 Keypad Functions 6 Parts Counting 7 The Memory Key and Function 8 RS232 Interface 9 Communication Port Settings 9 User Configurable Balance Parameters 10 Printing...

Страница 4: ...0 1g 0 1g 5 5 x 5 7 141 x 145mm PK 4 4000g 1g 1g 5 5 x 5 7 141 x 145mm PK 6 6000g 1g 1g 5 5 x 5 7 141 x 145mm PK 10 10 000 1g 1g 5 5 x 5 7 141 x 145mm Common Specifications Dimensions L x W x H 10 3 x...

Страница 5: ...tons for tactile feel and audio function tone Housing is constructed of sturdy ABS material with special structural cross bracing for added rigidity 9V battery operation for complete portability Bubbl...

Страница 6: ...set weighing pan onto top of unit until level Gently apply all items to be weighed onto the center of pan Although designed to be quite durable avoid rough treatment as this may perma nently damage t...

Страница 7: ...e desired electrical outlet Check you use of any extension cord which may affect power output Unplug AC adapter when not in use for extended periods Battery Operation 1 To install battery open battery...

Страница 8: ...stable 0 with an arrow in the g gram mode press and hold the CAL MODE button until calibration weight value appears on the display 3 Gently place the correct calibration weight onto the pan 4 The sign...

Страница 9: ...time Tare can also be used to eliminate the value of a pan liner scoop beaker etc from a sample or procedure when the weighed material needs to be held in a container and only the net weight of the ma...

Страница 10: ...e used when turned on again The right facing arrow will point to the weighing mode the unit is cur rently displaying To change modes briefly press the CAL MODE key to scroll between grams g ounces oz...

Страница 11: ...ow the sample to stabilize for 3 5 seconds then press TARE The parts counting function is now set for the selected 5 10 20 50 piece quantity and you can start the counting procedure IMPORTANT Minimum...

Страница 12: ...ou are ready to see the cumulative weight of all samples weighed 4 To view the cumulative weight press and hold the ON MEMORY key until a beep is heard When the beep sounds the memory buffer is dumped...

Страница 13: ...1 digit 1 3 4 2 digits 1 3 5 4 digits External CAL Units 1 4 1 grams default External Calibration 1 5 1 external calibration is enabled default 1 5 2 external calibration is disabled Auto Zero 1 6 1 o...

Страница 14: ...fly press the CAL MODE key Increment each digit segment by the method explained in 2 above 4 When switching from the center to right segment the number displayed is the setting that is currently selec...

Страница 15: ...not configurable baud rate parity stop bits and handshake 3 If the balance is set to manual print default press and hold the TARE PRINT key until an audible beep is heard The LCD contents will be sen...

Страница 16: ...ypad Changes balance state ESC O Enable Balance Keypad Changes balance state ESC R Print When Stable Performs a function ESC P Tare Performs a function ESC T Invoke External Calibration Performs a fun...

Страница 17: ...ditions Before pushing the exist CAL MODE button the LCD should display a stable ZERO with the arrow mode E E 1 10 0 There is a value stored Clear the memory or in the memory when the turn the balance...

Страница 18: ...240V 50Hz 400084 1 For use in Europe AC 240V 50Hz 400081 1 For use in Japan AC 100V 50 60Hz 400083 1 Calibration Weights PK 202 1 PK 352 1 200g Class M1 400218 1 PK 401 1 PK 601 2 200g Class M2 400073...

Страница 19: ...n Number Please pack the product securely in its original approved packing carton or an other suitable container Include your Return Authorization Number on the shipping label Shipping charges must be...

Страница 20: ......

Страница 21: ...standards traceable to the National Institute of Standards and Technology This instrument has been fully inspected and has passed all quality tests as specified by Denver Instrument Company quality p...

Страница 22: ...1 U K and Ireland Denver Instrument Company Denver House Sovereign Way Trafalgar Business Park Downham Market Norfolk PE38 9SW England Tel 44 136 63862 42 Fax 44 136 63862 04 Europe Asia and Australia...