Warranty 

Dentsply Sirona's Infection Control products are designed expressly for dental use, and this warranty is not applicable 
to other uses. The products are warranted against defects arising from faulty materials or workmanship from date of 
purchase for a period of 2 years. Parts will be repaired or replaced at the discretion of Dentsply Sirona.

This warranty extends to Resurge Ultrasonic Cleaner products purchased from an authorized Dentsply distributor, and 
only to the original purchaser. The Warranty is subject to the following conditions:

1. The online product registration must be completed online within four (4) weeks of date of purchase.  

 

   

Go to www.dentsplysirona.com/resurgeultrasonic.

2. Any servicing of the Resurge Ultrasonic Cleaner must be performed by Dentsply Sirona's service personnel. Contact   
  tech support at 1-800-637-8586.

3. Any warranty repair must be performed by Dentsply Sirona's service personnel.

4. Customer is responsible for shipping both ways outside of the continental USA, one way within. Contact us first,  
  then send the unit with a copy of the original invoice or receipt back to: 

Description

Resurge Ultrasonic Cleaner

Model

0.8 Gallon - 0060100

Tank Capacity

3 L/ 0.8 gallon (US)

Max. 2.5 L/ 0.65 gallon (US)

Min. 1.5 L / 0.4 gallon (US) 

Tank Size

25.0x17.4x7.8 cm 
 9.8inx6.9inx3.1in

Longest Item Fit Inside Tank

26.6 cm 

10.5in

Power Supply

170W ( AC 100~12ov 50Hz)

170W (AC 220~240V 50/60Hz) 

150W (AC 100V 50/60Hz)

Digital Timer Settings

Drainage

Drainage valve

Ultrasonic Frequency

35,000 Hz

Tank Material

Stainless Steel SUS304

Housing Material

ABS

Net Weight

5.1 kg/ 11.3 lb

Gross Weight

6.1 kg/ 13.4 lb

Unit Size

45.5x27.5x21.0 cm / 17.9"x10.8"x8.3"

Inner Carton Size

49.0x31.5x28 cm/ 19.3"x12.4"x11"

Qty per Master Carton

1 pcs/ctn

Master Carton Size

61.5x41.0x37.0 cm/ 24.2"x16.1"x14.6"

Specifications

› 10min  ›  15min  ›  20min  ›  25min  ›  30min  ›  5min

Dentsply Sirona
1301 Smile Way, York, PA 17404 USA
800-637-8582

THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. DENTSPLY neither 
assumes, nor authorizes any person to assume for it, any other liability in connection with the sale or use of its products. DAMAGES ARE LIMITED 
STRICTLY TO REPAIR OR REPLACEMENT OF PARTS. DENTSPLY EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL 
DAMAGES RESULTING FROM THE USE OF THE PRODUCTS.

Claims covered by this warranty will be honored when presented through your DENTSPLY Sirona distributor within thirty (30) days from discovery 
of defect within the applicable warranty period.

13

P/N 0060161CO Rev. 4 (1117)

Manufactured for:
Dentsply Sirona
1301 Smile Way
York, PA 17404 USA

Содержание Resurge 0060100

Страница 1: ...ec 2017 Approvals Sign off By Role Sign off Date DPD Document Control 11 Dec 2017 8 52 pm GMT Yerika Ramirez DPD Marketing Management 12 Dec 2017 12 49 pm GMT Dave Kierce DPD Quality Engineer 18 Dec 2017 11 11 pm GMT Maeve Bowers DPD Quality Assurance Regulatory Management 21 Dec 2017 5 10 pm GMT Heather Shellenberger DPD Document Control 22 Dec 2017 4 32 pm GMT Lucy Brenneman ...

Страница 2: ...r Finished Size 5 x 8 inch Languages English Graphics Revision Rev 4 11 17 Notes 1 Package to prevent damage 2 Artwork is maintained by DENTSPLY Professional York PA 17404 Revision History Rev Description of Change Author Dept Change No 1 Release of English only version of DFU R Gross Marketing CHO 074631 2 Update DFU with correct diameter symbol on page 1 and 2 R Gross Marketing CHO 076696 3 Upda...

Страница 3: ...cer Ø 45 mm stack transducer about 30 more powerful than standard stack transducers Multiple circuit protectors When overloaded or improperly used the protectors shut down the power to certain areas to protect the machine Moisture proofed Printed Circuit Board with industrial IC PCBs are placed vertically for better moisture proof performance Better anti interference Two cooling fans Improve heat ...

Страница 4: ...6 timer settings simple temperature setting simple and straightforward to operate Control panel with capacitive sensing technology durable reliable resistant to water and harsh chemicals Memory feature recalls last timer setting User friendly Electrical circuit features 1 Super sized ultrasonic transducer Ø 45 mm stack transducer about 30 more powerful than standard stack transducers 2 Multiple ci...

Страница 5: ... 1 Safety Precautions 1 2 2 Product Structure and Accessories 3 3 Control Panel and Operations 4 4 Operation Guidelines 5 7 5 Common Cleaning Methods 8 9 6 Care and Maintenance 10 7 Optional Accessories 10 8 Warranty 13 ...

Страница 6: ...cturer When removing the power cord from the socket grab the power plug not the cord To protect the power cord from damage do not cause it to get caught by things such as a cupboard door or a chair leg do not drag across a hot surface If there is damage to the power plug cord housing or other parts of the device do not use the device Contact your dental dealer for a replacement Do not disassemble ...

Страница 7: ...ubjected to severe electromagnetic interference it may malfunction stop operating or lose control functions If this happens unplug the power cord then reinsert it to restart the device Read all the instructions before using the appliance Only use attachments recommended or sold by the manufacturer Do not use outdoors To disconnect turn the power switch on the back of the unit to the off 0 position...

Страница 8: ...ture and Accessories Optional Accessories Standard Accessories Power cord See following page Hose Stainless steel rack and tray Single beaker holding set Indirect cleaning tank 3 1 3 5 6 8 2 4 7 9 0 8 Gallon 3 Liter ...

Страница 9: ...warning light then turns off and the operation can be resumed You do not need to turn unit off Start Stop Button After powering on the LED displays the last timer setting and the unit is ready under normal cleaning mode Touch Start Stop key twice and the cleaning starts The cleaning stops when the timer counts down to 00 00 If the unit needs to be stopped before the timer runs out touch Start Stop...

Страница 10: ...ctions for use for proper automated cleaning Prolonged cleaning time may result in a Loosening of the screws if used b If items are plated and have existing cracks the cracks may become more pronounced c Coating with preexisting damages may experience more peeling Degas Procedure a Add warm water to below the max fill line b Add Resurge Instrument Cleaning Solution per the instructions for use c T...

Страница 11: ...red time b Touch the Start Stop key twice to activate the cleaning cycle c When cleaning cycle is completed open the lid and retrieve the tray s or cassettes Draining Tank At the end of the day the tank should be drained and fresh water and cleaning agent added a Turn off unit b Connect the hose to the drainage pipe as shown c Turn the drainage valve handle clockwise to open the drain and remove t...

Страница 12: ...ting is changed but the cleaning cycle is not started it will stay until the cleaning cycle is started It will not stay if the power is turned off f If the Start Stop key is touched twice during the cleaning cycle the cycle will stop and the timer setting will stop running It ll resume the original cycle once the Start Stop key is touched twice again g If the power is turned off while degas is run...

Страница 13: ... can reduce the friction between the items and the tank Stainless steel basket absorbs approximately 8 of ultrasonic energy plastic basket absorbs about 35 of ultrasonic energy This significantly reduces the cleaning effectiveness 2 During cleaning dirt will come off like a cloud and the water will become murky over time This is debris being removed from the instruments and indicates the instrumen...

Страница 14: ...e recommended container Add your instrument cleaning solution We recommend Resurge Instrument Cleaner Make sure you follow the instrument cleaning solution instructions for use 2 Place the container in the tank directly Add water to a level between MIN and MAX at least half inch or 13 mm above the bottom of the container but not over the container 3 Turn the power switch on Touch Time key to set t...

Страница 15: ...room temperature then reconnect the power automatically Do not run the unit for extended time or continuously The unit is designed with overheat protection If the unit has been running for 45 minutes it is recommended to stop the unit for about 20 minutes to prolong the life of the unit Do not keep water in the cleaning tank at the end of the day After cleaning is completed open the drainage valve...

Страница 16: ...11 PAGE INTENTIONALLY BLANK ...

Страница 17: ...12 PAGE INTENTIONALLY BLANK ...

Страница 18: ...Max 2 5 L 0 65 gallon US Min 1 5 L 0 4 gallon US Tank Size 25 0x17 4x7 8 cm 9 8inx6 9inx3 1in Longest Item Fit Inside Tank 26 6 cm 10 5in Power Supply 170W AC 100 12ov 50Hz 170W AC 220 240V 50 60Hz 150W AC 100V 50 60Hz Digital Timer Settings Drainage Drainage valve Ultrasonic Frequency 35 000 Hz Tank Material Stainless Steel SUS304 Housing Material ABS Net Weight 5 1 kg 11 3 lb Gross Weight 6 1 kg...