background image

2.3 THE PACKAGING CONTAINS 

• 1 complete water softener IV 
• 1 instruction manual  
• 1 drain pipe 
• 2 joints for connection to the water sullpy network 
 

2.4 TECHNICAL FEATURES 

Pressure of feed water:  

0,1 ÷ 0,8 MPa (1 ÷ 8 bar) 

Nominal flow rate at 4 bar:  

800 l/h 

Room temperature:  

4°C - 35°C 

Joints for the connection to the water 
network:  

- inlet 3/4 "G (for normal washing machine or model trimmer hose 
- outlet for D. = 8x6 hose) 

 

2.5 FEATURES OF FEED WATER 

Feed water must be: 
• Drinkable and clean 
• Temperature must be between 6° and 25°C 
• Hardness must be below 900 ppm CaCO3 (90°f)  
 

2.6 EQUIPMENT PERFORMANCE BASED ON WATER HARDNESS 

 

 
 

3. INSTALLATION 

3.1 PACKAGING 

• Before the installation, check that the equipment was not damaged by the transport and does not show any 
anomaly. In case of doubt, ask your seller. 
• Don’t throw the package away for some time, being careful to keep any dangerous or small parts of the package 
away from children. 
 

3.2 CHOOSING THE PLACE OF INSTALLATION 

• Ensure that any other water treatment machine is not present upline of the place of installation. 
• Ensure that feed water comes from a drinking water pipe. We recommend to check the chemical and physical 
parameters of the drinking water as well as its hardness before installation. 
• Install the equipment near a floor sink to dispose of the waste water produced by the regeneration.  
• Install the equipment in a dry place easily accessible to maintain, regenerate and clean the equipment.  
Do not install the equipment in dirty and unhygienic places or in any place difficult to clean.  
• Ensure that room temperature in the place of installation is between 4°C and 35°C. 
• Keep away from corrosive or acid products. 
• Do not install in places where electric or personal safety regulations are openly disregarded. 
• Hydric pressure must not be under 0.1 Mpa (1 bar) or over 0.8 Mpa (8 bar). (We recommend at least 3 or 4 bar) 
• If water pressure is over 8 bar, it will be necessary to install a pressure regulator. 
• Salt packages or boxes must not be kept in humid places or in direct contact with the floor: keep it, for example, 
on a wooden pallet.  

Содержание H8

Страница 1: ...WATER SOFTENER mod H8 USER AND MAINTENANCE MANUAL ...

Страница 2: ...E REGENERATION 4 1 RINSING RESINS 4 2 PERIODIC REGENERATION 4 3 MIXER CONTROL 5 MAINTENANCE FOR THE INSTALLER 5 1 CHANGING THE RESINS 5 2 RESIN PRESERVATION AND ACTIVATION AFTER A LONG PERIOD OF INACTIVITY 6 IMPROPER USE OF THE EQUIPMENT 7 EQUIPMENT DISPOSAL 8 EXPLODED DRAWING AND SPARE PART LIST WARNINGS FOR THE USER This equipment must not be used by children or by people with physical mental or...

Страница 3: ...ponsibility for any damage caused to people things or animals and will consider the guarantee null and void 1 2 KEEPING THE MANUAL This manual is an integral part of the product It must be kept with care by the user and it must accompany the equipment even in case of a property transfer 1 3 EQUIPMENT IDENTIFICATION The equipment is identified by the numbers written in bold on the bottom left side ...

Страница 4: ...EQUIPMENT 2 1 HOW DOES IT WORK The cationic resins in the softener s tank transform calcium carbonate in sodium carbonate which is water soluble at the working temperatures of both coffee and ice machines The transfer of sodium ions between the resins and water is imperative to soften drinking water but this process tends to decline in proportion to the flow rate and to the consumption of water Fo...

Страница 5: ... INSTALLATION Ensure that any other water treatment machine is not present upline of the place of installation Ensure that feed water comes from a drinking water pipe We recommend to check the chemical and physical parameters of the drinking water as well as its hardness before installation Install the equipment near a floor sink to dispose of the waste water produced by the regeneration Install t...

Страница 6: ... from disconnecting To remove the pipe it is necessary to depressurize the tank then press on the black ring that surrounds the pipe next to the insertion and extract the pipe Ensure that The water inlet and outlet pipes comply with the regulations on drinking water pipes A water inlet tap C must be installed by the user between the water system and the water softener to ensure that water flow can...

Страница 7: ...not take responsibility for the corrosion of the tank caused by the failure to follow these instructions Put the lid back on pic 1 G and tighten the cover handle pic 1 F safely Position 3 RINSING MODE Turn the valve handle on number 3 Let the salt water come out from the drain pipe until the water is fresh around 40 minutes Position 4 BACKWASH CLEANING MODE Turn the valve handle on number 4 and wa...

Страница 8: ... the resins or if it is better to replace the water softener itself To change the resins it is necessary to turn the valve handle on number 2 pic 3 Wait a few seconds until tank depressurization When water stops coming out of the drain move the plastic blocks outwards pic 3 A It will then be possible to separate the valve from the tank pic 3 B Bring the tank to an appropriate place to change the r...

Страница 9: ...ment must not be used for any different purpose and it must not be modified or tampered with in any way Any other use than the one specified in this manual is improper and therefore dangerous The manufacturer cannot be considered responsible for any damage caused by improper mistaken or illogical use of the equipment It is forbidden to feed the equipment with any liquid other than drinking water I...

Страница 10: ......

Страница 11: ...T PIPE 14 B3 BASAMENTO BASE 15 VB3 RACCORDO 3 8 G T10 3 8 G T10 PIPE FITTING 17 VB4L RACCORDO 3 4 G T10 3 4 G T10 PIPE FITTING 18 NPR119 RACCORDO 8x6 1 4 8x6 1 4 PIPE FITTING 20 VB5 TAPPO MANOPOLA IV IV KNOB CAP 21 VB6 O RING 114 OR JOINT 114 22 VB7 MANOPOLA IV IV KNOB 23 VB8 COPERCHIO VALVOLA IV IV VALVE CAP 24 VB36 MISCELATORE IV IV MIXER 25 VB12 MOLLA VALVOLA IV DIA 21x26 IV VALVE SPRING Ø21x26...

Страница 12: ......

Страница 13: ......

Страница 14: ...DENTALFARM s r l Via Susa 9 a 10138 TORINO ITALY COMMERCIAL SERVICE 39 011 4346588 TECHNICAL SUPPORT 011 4346632 FAX 011 4346366 E mail info dentalfarm it Web www dentalfarm it ...

Отзывы: