background image

Simplicity

®

 Cart 

20  

  

 Installation, Operation and Care Manual   

Section VIII  Parts List/Diagrams

1

2

5

11

3

8

7

6

4

10

9

14

15

16

12

13

17

*Optional Equipment

#

Part/Kit Name

Part/Kit No.

1 Master ON/OFF Switch

3801-960

2 Water Adjustment Valve

3801-922

3 Flush Toggle

3801-976

4 Water Control Valve

3800-417

5

Gauge Assembly

3802-083

6 Oil Collector Cover & Filter

3802-211

7 Water Bottle Manifold

3801-718

8 Water Bottle, 1.5L

3802-182

9 Pressure Regulator

3801-867

*10 City/Bottle Routing

3802-090

11 Bottle ON/OFF Switch

3802-091

12 Water Outlet

3801-854

13 Water Adjustment Valve

3801-208

14 Poppet Valve Assembly

3802-192

15 Handpiece Holder, Universal

3801-697

16 Handpiece Holder, Automatic

3801-696

17

Water Bottle Gasket

3802-342

18 Solids Collector Traps

3625-338

19 Solids Seperator Assembly

3801-594

Water Bottle Replacement Kit, 1L

3802-363

Delivery Head / Clean Water System       

19

18

Содержание Simplicity

Страница 1: ... Installation Operation Care Manual Simplicity Cart Duo Doctor s ...

Страница 2: ...f Control Symbols 9 Section IV Testing Delivery System 10 Foot Control Handpiece 10 11 Syringe 11 Fiber Optics Optional 11 SectionV Operation Delivery System 12 Handpiece 13 Syringe 14 Foot Control Chipblower 14 Fiber Optics Optional 14 Clean Water System 14 SectionVI Care Cleaning 15 Disinfecting 15 SectionVII User Service Information Delivery Head 16 Handpiece 17 18 Service Instruction 18 Dispos...

Страница 3: ...ility Service Compartment Clean Water System Doctor s Controls BASIC COMPONENTS Work Surface Specifications Power Supply 100 240V 50 60 Hz as applicable Air Pressure 551 6 pKa 80 PSI at regulator in USC Water Pressure 275 8 pKa 40 PSI at regulator in USC CleanWater System Reservoir Capacity 1 5 L CMU Shipping Weight Cart with transformer 61 2 kg 135 lbs Cart without transformer 47 6 kg 105 lbs Max...

Страница 4: ... follow instructions European Certification Serial Number Manufacture Date Manufacturer Explanation of Symbols and Signs SN In accordance with Part 15 of FCC rules this equipment was tested and complies with Class A digital device limits These limits are designed to give equipment reasonable protection against detrimental interference when operated in a commercial environment Medical electrical eq...

Страница 5: ...s 2 Fitting Assembly 10 x 1 2 Screws 4 Actuator Valve Assembly Assistant s Arm Supply Bag Duo only HVE Aseptic Sterling Tubing SE Sterling Tubing HVE Handle Valve SE Handle Valve Disposable Solid Trap Pkg Assembly Section I Introduction SHIPPING CONFIGURATION Cart Assembly Option Box Insert Foot Control Box USC Box Pallet Installation by an authorized DentalEZ dealer service technician is recommen...

Страница 6: ...ve Water Stop Valve Vacuum Elbow WALL SIDE Plumbing Contractor s Procedure 1 Remove the full size USC template found in the USC Carton 2 Position the USC template according to the exact layout indicated making certain correct distance from base to chair is maintained 3 Using the USC template drill two mounting holes for the USC base But do not secure the base to the floor at this time Typical Layo...

Страница 7: ...mplate 7 Flush the air and water lines to remove trash and debris from the lines 8 Connect the water actuator valve assembly to the water stop valve as shown in the template Using a 5 8 open end wrench tighten the nut securely 9 Connect the air fitting assembly to the air stop valve as shown in the template Using a 5 8 open end wrench tighten the nut securely Typical Layout Before proceeding with ...

Страница 8: ... 5 Open the air stop valve and check for leaks 2 Slide a 1 4 tubing clamp onto the red air line from the umbilical Connect this line to the remaining 1 4 barb on the air regulator assembly 5 8 Vacuum Line Incoming Green Water Line Green Line Marked W Water Regulator Before making tubing connections use soap to lubricate all in line barbs and lines After making each connection secure by sliding an ...

Страница 9: ...e instrument holder 3 Connect the tubing to an open 1 2 port under the solids collector located under the cart 4 If an optional second HVE valve is used do the following a Insert a sharp pointy object into the closed 1 2 port under the solids collector and create a smooth opening b Repeat Steps 1 through 3 Air Water Syringe Optional NOTE Connections for the optional air water syringe are factory i...

Страница 10: ...ry head chassis NOTE If the optional fiber optics were included in the original order electrical connections have been made inside the delivery head at the factory Plug the fiber optic transformer into the outlet and the harness from the cart umbilical ON Power Standby Power Water No Water Flush Chip Air Water Bottle City Water Handpiece Drive Air Coolant Air Coolant Water Variability Explanation ...

Страница 11: ...et 1 At the foot control flip the toggle valve to WET 2 Purge air from the coolant water lines for each handpiece as follows a Make sure master switch is in ON position b Open the water coolant valve to the full open position c Pick up a handpiece tubing and lay the end into a sink or cuspidor bowl d Simultaneously depress the foot control disc and hold the flush valve located in the back of the d...

Страница 12: ...justment Screws d Turn the air pressure adjustment screw on the control valve of the appropriate handpiece counterclockwise to increase pressure clockwise to decrease pressure until the handpiece manufacturer s correct specification registers on the pressure gauge 3 Repeat a through d in Step 2 to set the pressure for each handpiece NOTE If a low speed handpiece is required slide the pinch clamp o...

Страница 13: ... be adjusted by using an Allen wrench to loosen two set screws in the back of each section and rotating it to the desired angle then re tightening the screws An oil collector filter is designed to collect oil from the handpiece exhaust air Once a week check the filter for cleaning or replacement by removing the two screws that secure the filter cover Hanger Bar Handpiece Holder Section Automatic C...

Страница 14: ...er the heading Air Pressure on Page 11 NOTE These procedures must be done while The master switch is in the ON position The handpiece is out of its holder and The foot control is fully depressed NOTE When making necessary air pressure adjustments refer to the air pressure gauge located at the side of the cart to check the approximate amount of air pressure delivered to the handpiece Coolant Water ...

Страница 15: ...ndpiece is controlled by depressing the disc located on the foot control A light pressure on the foot control disc causes a slow speed Fiber Optics Optional If the handpiece utilizes coolant air the chipblower feature is used to blow debris away from the cutting site by creating an air blast through the handpiece without causing the burr to rotate To operate the chipblower depress and hold down th...

Страница 16: ...al disinfectant for the delivery unit NOTE Cavicide is the recommended disinfectant for use on all external surfaces Cavicide is a trademark of Micro Aseptic Products Inc Avoid using disinfectants in spray containers because they may cause premature staining discoloration and or damage to the Simplicity Cart Delivery Unit CAUTION SlugBusterTM solution and cleaning brushes for assistant s instrumen...

Страница 17: ...g of valve If air is present at top fitting of valve verify air to foot control tubing If no air at tubing valve is defective Unit has no electric power No building power Check main circuit supply or contact electrician Improper outlet voltage Verify proper outlet voltage in USC Unit has no air Unit is not turned on Ensure master switch is in ON position Air stop valve is closed Turn stop valve ON...

Страница 18: ...ted tubing from foot control Straighten or replace tubing Low air pressure Ensure air regulator gauge in floor box reads 80 PSI No fiber optic light at handpiece Power transformer is not plugged in Plug transformer into designated receptacle in USC Internal wires in control head and or USC are not connected Check connections in control head and or USC No signal air to fiber optic lamp control Chec...

Страница 19: ... regulatory requirements for disposal and decommissioning of equipment apply Electrical Salvage Remove fiber optic controller and transformer Metal Salvage Remove all aluminum and steel components for recycle as metal salvage Plastic Salvage Remove all plastic components for recycle as plastic salvage Biologically Contaminated Salvage Oral extraction lines should be handled with precaution and dis...

Страница 20: ...e Gauge 3800 534 5 Water Regulator 3802 107 6 Water Pressure Gauge 3800 533 7 Air Regulator Bowl Watts 3802 267 8 Water Regulator Bowl Watts 3802 268 9 Water Air Regulator Repair Kit Watts 3802 273 10 Water Regulator Filter Watts 3802 270 11 Air Regulator Filter Watts 3802 271 12 Regulator Retainer Watts 3802 272 Water Regulator Gauge Repl Kit Watts 3802 269 Air Regulator Gauge Repl Kit Watts 3802...

Страница 21: ...tor Cover Filter 3802 211 7 Water Bottle Manifold 3801 718 8 Water Bottle 1 5L 3802 182 9 Pressure Regulator 3801 867 10 City Bottle Routing 3802 090 11 Bottle ON OFF Switch 3802 091 12 Water Outlet 3801 854 13 Water Adjustment Valve 3801 208 14 Poppet Valve Assembly 3802 192 15 Handpiece Holder Universal 3801 697 16 Handpiece Holder Automatic 3801 696 17 Water Bottle Gasket 3802 342 18 Solids Col...

Страница 22: ...t Kit No 1 Diaphragm Repair Kit 3800 749 2 Manifold Assembly 3 HP no lock out 3802 219 3 Tubing Slide Clamp 2533 074 Manifold Part Kit Name Part Kit No 4 Replacement Block 3 HP 3802 320 5 Replacement Block 4 HP 3802 321 Control Block Repair Kit 3 HP or 4 HP 3802 324 Control Block ...

Страница 23: ...2 160 2 Cart Knob 3800 111 3 Cart Lid 3802 260 4 Hanger Bar 3802 261 5 Handpiece Holder Universal 3801 697 6 Handpiece Holder Automatic 3801 696 Cart Replacement Parts Part Kit Name Part Kit No 7 Drive Air Repair Kit 3802 417 8 Wet Dry Toggle Valve 3802 418 9 Chip Air Valve 3802 419 10 Shuttle Valve Kit 3801 585 Foot Control Complete 3801 706 Foot Control ...

Страница 24: ...artridges 3802 335 2 Syringe Tip Kit 3802 205 3 O Rings Complete Set 3658 420 Air Water Syringe Part Kit Name Part Kit No HVE Repair Kit 3802 154 Full Replacement Parts Kit 3801 927 HVE Nozzle Part Kit Name Part Kit No SE Repair Kit 3802 153 Full Replacement Parts Kit 3801 926 SE Nozzle ...

Страница 25: ...or a period of three 3 years from the date of installation with the exception of the following items which are covered under this warranty for a period of one 1 year from the date of installation Tubings and Fittings Syringe Wiring Handpiece Tubings Please note the following additional terms of our warranty and return policy Warranties cover manufacturing defects only and do not cover defects resu...

Страница 26: ...low and are not likely to cause any interference in nearby electronic equipment RF Emissions CISPR 11 Class A The Simplicity Cart is suitable for use in all establishments other than domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Not Applicable Voltage fl...

Страница 27: ...typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 di...

Страница 28: ...ing to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P v d 1 5 3 80 MHz to 800 MHz P E d 1 5 3 800 MHz to 2 5 GHz P E d 1 7 0 01 0 12 0 12 0 23 0 1 0 34 0 34 0 74 1 1 7 1 7 2 3 10 3 7 3 7 7 4 100 11 7 11 7 23 3 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equ...

Страница 29: ...rengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by abso...

Страница 30: ...CUATOR DUO CART ONLY WATER RETRACTION VALVE 1 8 YELLOW 5 8 SPIRALOCK UMBILICAL MASTER SWITCH WATER ADJUSTMENT AIR GAUGE SOLIDS COLLECTOR DUO CART ONLY 1 2 ID STERLING WATER PRESSURE ADJUSTMENT VALVE 1 8 RED 1 8 GREEN 1 8 TWIN STERLING HANDPIECE HOLDER 1 8 TWIN STERLING SYRINGE SALIVA EJECTOR DUO CART ONLY WATER BOTTLE SWITCH PN 2662 289A POWER MODULE 2 3 1 1 8 TWIN STERLING SYRINGE PLUGGED PORT 1 ...

Страница 31: ...2500 Highway 31 South Bay Minette Alabama 36507 1 866 DTE INFO Fax 251 937 0461 www dentalez com DentalEZ Alabama Inc Printed in USA PN 2717 258A October 2014 ...

Отзывы: