background image

9

www.DentalEZ.com

 866-DTE-INFO

9

DentalEZ

®

 

Equipment

PN: 2717-256E

Section II  Preinstallation

Packaging

Tools Required

• 

Pliers

• 

1/2" Socket & Ratchet

Unpacking Chair Carton

1.  Using pliers, remove the staples that secure the 

shipping carton to the wooden pallet.

2.  Remove the carton and packing inserts from 

the pallet by lifting up.

3.  Using a 1/2" socket and ratchet, remove the two 

bolts that secure the chair base to the shipping 

pallet.

4.  Grasp the chair mount casting and slide the 

chair o

ff

  of the pallet. 

(If air glide equipped,

 

do 

not slide

.

5.  Remove and set aside the following items from 

the chair carton for installation:

• 

Upholstered seat

• 

Headrest

• 

Chair controls

• 

Any ordered options

• 

Hardware package

•  During transportation, the chair must be 

at its lowest height and all attachments 

must be secured in their lowest and 

most central positions possible. Failure 

to comply may result in injury and/or 

damage to equipment.

•  The NuSimplicity Chair is shipped with 

a retaining strap to secure the base 

mechanism. 

DO NOT REMOVE

 this strap 

until the chair is out of the carton and in 

its position on the 

fl

 oor.

•  The chair is heavy and weighs in excess 

of 300 lbs. (depending on options). Use 

assistance to remove the chair from 

the pallet. Failure to do so may result in 

serious back injury.

•  DO NOT CONNECT

 the chair 

POWER

 cord 

until all shipping hardware is removed.

WARNING

•  To avoid damage to the carton contents, 

do not use a knife or sharp object to open 

the packaging.

•  If the chair is equipped with an air glide 

option, be careful not to damage the air 

bladder when lifting (do not slide) the 

chair o

ff

  of the delivery pallet and during 

placement of the chair.

CAUTION

Содержание NuSimplicity

Страница 1: ...NuSimplicityTM Chair User Manual ...

Страница 2: ...ols 13 Air Glide Optional 15 Upholstery 16 Installation Checklist 18 Section IV Operation Base Lowering Safety Switch 19 Chair Rotation 19 Armrests 20 Standard Fixed Headrest 20 Double Articulating Headrest Optional 21 Air Glide Optional 21 Manual Chair Positioning 22 Automatic Chair Positioning 23 Programming Chair Travel Limits 24 Control Valve Speed Adjustment 25 Section V Care Cleaning 27 Disi...

Страница 3: ...www DentalEZ com 866 DTE INFO ii NuSimplicityTM Chair PN 2717 256E ...

Страница 4: ...hair Headrest Back Seat Armrest Brake Base Cantilever Section Base Pump Cover Armrest Base Plate Touchpad Foot Control Wired or Wireless This manual contains the installation operation and care instructions and user service information for the DentalEZ NuSimplicity Chair The NuSimplicity Chair is intended to be used by trained professional dental care personnel only The dental chair supports a pat...

Страница 5: ...top of chair back Easily visible illuminated ON indicator Slim wider cantilever for ease of internal umbilical Integrated touchpad controls located on both sides of upper backrest provide easy and rapid patient positioning Simple chair controls include auto return last position three presets and manual settings Seamless or seamed upholstery Fixed headrest Base safety switch feature ensures nothing...

Страница 6: ...E INFO 3 DentalEZ Equipment PN 2717 256E Section I Introduction Dimensions Figure 2 Top view side reclining and side upright dimensions for the NuSimplicity dental chair 26 30 36 56 64 42 13 17 17 19 12 72 18 8 26 9 18 22 25 27 ...

Страница 7: ...www DentalEZ com 866 DTE INFO 4 NuSimplicityTM Chair PN 2717 256E Section I Introduction Range of Motion Figure 3 Range of motion for the NuSimplicity dental chair 30 30 ...

Страница 8: ...72 kg Maximum Patient Weight Factory tested to lift a load of 300 lb 136 kg Shipping Package Dimensions 58 5 L 34 H 32 5 W Specifications Minimum Installation Space 10 10 3 m 3 m Base Plate Footprint 42 25 106 cm 64 cm Recommended Environmental Conditions TransportationandStorage Temperature range 20 F to 165 F 29 C to 74 C Relative humidity range 0 to 95 Operation Temperature range 41 F to 104 F ...

Страница 9: ...chanical hazards only in accordance with UL 60601 1 CAN CSA C22 2 NO 601 1 CAN CSA C22 2 NO 60601 1 08 ANSI AAMI ES60601 1 2005 53HN RISK CLASS 2G The authorized European representative is Dental Hygienics Decontamination DHD 41 Blackwell Drive Braintree Business Park Braintree Essex CM7 2PU UK Phone 44 01787 877877 ext 200 Caution Warning Biohazard Warning Dangerous Voltage General Mandatory Acti...

Страница 10: ...acle NOTICE Before proceeding with electrical installation all wiring must be in accordance with NEC and local electrical codes To avoid the risk of electrical shock this equipment must only be connected to a supply mains with protective earth Do not modify the NuSimplicity Chair without permission from DentalEZ The use of ACCESSORY equipment not complying with the equivalent safety requirements o...

Страница 11: ...vice pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications however there is no guarantee that interference wi...

Страница 12: ... chair must be at its lowest height and all attachments must be secured in their lowest and most central positions possible Failure to comply may result in injury and or damage to equipment The NuSimplicity Chair is shipped with a retaining strap to secure the base mechanism DO NOT REMOVE this strap until the chair is out of the carton and in its position on the floor The chair is heavy and weighs...

Страница 13: ...holstery packaging NOTE The base cover must be removed before anchoring the chair Figure 5 NuSimplicity Chair anchor holes Anchor hole Anchor hole Unpacking Upholstery Carton If the upholstery is ordered separately from the chair remove and set aside the following items from the NuSimplicity Chair upholstery assembly packaging Figure 4 Upholstered back assembly Sling assemblies Upholstered seat Up...

Страница 14: ...eat frame tube 3 Using a Phillips head screwdriver and two 10 32 pan head screws one in front and one in the rear install a spring cover 4 Secure using four spring cover bracket screws two on top and two underneath 5 Repeat steps 2 through 4 for the opposite spring cover 10 32 Pan Head Screw Rear Spring Cover Bracket Screws Seat Frame Tube Spring Cover Bracket Spring Cover Phillips head screwdrive...

Страница 15: ...liary Wiring Harness Figure 7 Auxiliary wiring harness Delivery Units Install console mounted delivery units and Magellan style delivery units according to the manufacturer s instructions supplied with the delivery unit Section III Installation For more information regarding the installation of the additional controller follow the instructions supplied with the touchpad control package A wireless ...

Страница 16: ...ntrol and or wireless touchpad control options were ordered they must be paired with the NuSimplicity Chair Tools Required Phillips head Screwdriver Pair Wireless Devices to Chair 1 Raise chair base up its full UP position 2 Remove two 2 Phillips head screws from front of base pump cover and loosen two 2 screws in back of cover then slide off cover Figure 9 3 Make sure wireless device foot control...

Страница 17: ...ng correctly 9 Replace base pump cover Unpair Wireless Devices from Chair 1 Raise chair base up its full UP position 2 Hold the remote switch S3 on main chair power control board for 30 seconds Chair will stop beeping and wireless connections will be cleared 3 Re pair other devices as needed Wireless Control Operation After wireless control has been idle for an extended period of time foot control...

Страница 18: ...he air pressure by adjusting the air regulator on the base chassis until the chair begins to bounce This is an indication that the air pillow is over pressurized and can not seal to the floor Slowly decrease the pressure until the chair stops bouncing 4 Actuate the air regulator toggle switch Figure 16 at the rear of the chair on the base cantilever section cover Air Regulator Air Glide Tubing Fig...

Страница 19: ...hair Figure 18 and install the 1 4 20 thumb screw Slide Bosses Figure 17 Slide bosses Substrate 1 4 20 Thumb Screw Figure 18 Seat frame tube aligned to substrate Back Factory Installed NOTE Make sure the blind grip fasteners are firmly secured to the back of the upholstered chair back 1 Align the two upper and two lower blind grip fasteners on the upholstered chair back to the studs on the chair b...

Страница 20: ...ndard Fixed Headrest Blade Figure 20 Standard fixed headrest Blade Double Articulating Headrest Optional Chair Back Casting Opening Figure 21 Double articulating headrest optional 2 Place the magnetic headrest cushion on the chair or the fixed headrest of the chair Magnetic Cushion Figure 22 Headrest shown with magnetic cushion The headrest shown Figure 22 contains magnets which can interfere with...

Страница 21: ...on a few times to ensure proper function Does the rotational brake function properly Does the headrest stay in position after adjustment Is the foot switch or touchpad functioning correctly Do all chair functions operate smoothly and quietly Do the armrests lock into position Answering NO to any of these questions is the result of improper installation or a product malfunction After ensuring all c...

Страница 22: ... base will start moving upward immediately while the chair emits a constant short warning beep 3 Moving the base up and off of the obstruction deactivates the safety switches and silences the warning beep If any auto position buttons are pressed the chair will sound three short beeps to indicate auto positioning is not available The NuSimplicity Chair is capable of swiveling 30 to either side of i...

Страница 23: ... lock it into position Figure 24 NuSimplicity Chair armrest To position the standard fixed headrest Firmly push down or pull up the blade from the chair back to change the standard fixed headrest height Figure 25 NOTE The use of disposable headrest covers is recommended to prevent soiling of the headrest These covers may be purchased through a local dental supplier Standard Fixed Headrest Blade Fi...

Страница 24: ...supplier Release Mechanism Double Articulating Headrest Figure 26 Double articulating headrest The optional air glide aids the operator in repositioning the chair To operate the air glide option 1 Make sure the chair is on a smooth hard level and non obstructive surface 2 Activate the air regulator toggle switch on the base cover at the rear section of the chair Figure 27 3 The rear of the chair b...

Страница 25: ...igure 28 To operate these controls 1 Select the direction of travel base up base down back up or back down 2 Depress and hold the corresponding button to move chair to factory set travel limit NOTE The chair will continue running until the directional button is released Back Up Button Figure 28 NuSimplicity Chair touchpad control and foot control Base Down Auto Buttons 1 2 and 3 Back Down Button B...

Страница 26: ...exit position Last position mode The chair returns to the last position after one mechanical movement Automatic Chair Positioning Activating Auto Positions 1 Depress the 1 2 3 A or L button once on the touchpad control side of chair back foot control or the unit touch pad control 2 A beep will sound 3 The chair will automatically stop in the programmed position selected NOTE Pressing any button on...

Страница 27: ...limits have been set correctly Lower Limits 1 Press 2 and 3 on the chair mounted touchpad for five 5 seconds The chair will start to beep and the display will show LL lower limit 2 Lower the base and back to its lowest position limit switches will be engaged 3 Raise the chair base and back to the lowest desired height Ensure that the limit switches are not engaged 4 Press 1 on the chair mounted to...

Страница 28: ...he chair a Move the base up and down adjusting the flow controls until it takes 12 seconds for the base tomoveeitherupordownthefulltravel b Move the back up and down adjusting the flow controls until it takes 12 seconds for the back tomoveeitherupordownthefulltravel NOTE With the flow adjustments closed all the way the seat may not move at all until the valve is adjusted open a little CV1 CV2 UP D...

Страница 29: ...www DentalEZ com 866 DTE INFO 26 NuSimplicityTM Chair PN 2717 256E ...

Страница 30: ...e harmful or irritating Use protective gloves and eye protection in a well ventilated area Do not inhale or swallow any cleaning product Protect surrounding surfaces and clothing from exposure When using strong cleaning agents such as bleach or alcohol it is advisable to first test them in an inconspicuous area to be certain they will not damage the upholstery plastic or metal surfaces of the NuSi...

Страница 31: ...ds using commercial dry cleaning solvents Ultraleather is a trademark of Ultrafabrics LLC Plastic and Coated Metal Surfaces 1 To remove ordinary dirt Prepare a soapy solution comprised of neutral detergent household dish washing liquid and water Using a soft cloth or sponge apply this soapy solution to the plastic and coated metal surfaces NOTE To remove heavier dirt apply Formula 409 or Fantastik...

Страница 32: ... disinfectant products containing sodium hypochlorite common household bleach diluted 1 10 Mayer Savoy with PERMABLOK3 from Spradling Mayer Savoy fabrics with PERMABLOK3 advanced vinyl protection contain an antimicrobial and antibacterial protection on an anti stain finish that is easily cleaned Mayer Savoy with PERMABLOK3 provides exceptional disinfectability using a wide range of cleaning produc...

Страница 33: ...www DentalEZ com 866 DTE INFO 30 NuSimplicityTM Chair PN 2717 256E ...

Страница 34: ...l circuit board and electrical cabling for recycle as electrical salvage Metal Salvage Remove all aluminum and steel components for recycle as metal salvage Plastic Salvage Remove all plastic components for recycle as plastic salvage Biologically Contaminated Salvage Cuspidor waste lines from the cuspidor and the oral extraction lines should be handled with precaution and disposed of appropriately...

Страница 35: ...www DentalEZ com 866 DTE INFO 32 NuSimplicityTM Chair PN 2717 256E ...

Страница 36: ... Part Kit No Seamless Seat Cushion 3802 466 Seamless Seat Cushion Ultra 3802 466U Seamless Back Cushion 3802 467 Seamless Back Cushion Ultra 3802 467U Plush Seat Cushion 3802 468 Plush Back Cushion 3802 469 Standard Headrest Cushion 3801 827 Standard Headrest Magnetic Cushion 3801 826 Double Articulating Headrest Cushion Optional 3801 535 Back Substrate Blind Grip Fasteners 3801 742 Seamed Back Cu...

Страница 37: ...ww DentalEZ com 866 DTE INFO 34 NuSimplicityTM Chair PN 2717 256E Section VII Parts Lists Diagrams To order parts online visit www dentalezparts com or scan QR code with smartphone DentalEZ Parts Online ...

Страница 38: ...crete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical Fast Transient Burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV...

Страница 39: ...romagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the NuSimplicity Chair is used exceeds the applicable RF compliance level above the NuSimplicity Chair should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorientin...

Страница 40: ...ion Structures Base Plate Castings Chair Seat and Back Hydraulic System Cylinders Solenoid Valves and Pump Electronics Master Circuit Board and Foot Control Circuit Board Chair Control The upholstery package is covered under this limited warranty for a period of one 1 year from the date of installation Please note the following additional terms of our warranty and return policy Warranties cover ma...

Страница 41: ...2500 Highway 31 South Bay Minette Alabama 36507 866 DTE INFO www dentalez com DentalEZ Alabama Inc Printed in USA PN 2717 256E April 2019 ...

Отзывы: