background image

 

34

 

7.8  Multi-line Barcode Scanning 

The scanner can scan up to 3 lines of bar codes in the readable area at any one time. You can specify the number of 
lines to scan, the data output order and output format using the configuration software (ScannerSetting_2D). 

7.8.1  Number of lines 

The number of lines allowed for multi-line barcode scanning is 2 or 3. This setting is essential. 

7.8.2  Data output order 

You can specify the data output order by designating code types*

1

, heading characters*

2

, or the number of digits to 

scan*

3

*

1

  Code types should be selected from readable bar codes you enable. This setting is essential. 

*

2

  Up to two heading characters can be specified. If a question mark (?) is specified, it acts as a wild card. This setting 

can be omitted. 

*

3

  The number of digits to scan varies depending upon the code type. This setting is essential. 

7.8.3 Output 

format 

You may select either the header/terminator- or comma-delimited output format. 

(1)  Header/terminator-delimited output format 

Specifying this format allows the scanner to output multiple lines of barcode data in succession in the data 
transmission format selected (see Section 9.2) so that the headers and terminators act as delimiters. For UPC and EAN 
codes, the number of digits will be omitted. 

(2)  Comma-delimited output format 

Specifying this format allows the scanner to output multiple lines of barcode data delimited with commas in the data 
transmission format selected (see Section 9.2). Note that the scanner outputs the code ID mark specified for the first 
line barcode and the number of digits including the delimiter commas. The number of digits will not be omitted even 
for UPC and EAN codes. 

 

Note 1:

 Bar code types specified for multi-line barcode scanning cannot be read individually. 

Note 2:

 In the point scan mode or barcode reader mode, the scanning conditions specified for multi-line barcode 

scanning are invalid so that the scanner scans codes individually. 

Note 3:

 The scanner cannot read multi-line barcodes of UPC/EAN with add-on. 

Note 4:

 If linear components in a UPC/EAN Composite symbol are specified for multi-line barcode scanning, all 

EAN.UCC Composite symbols including the specified linear components cannot be read.   

 

7.9  Scanning an SQRC (Security QR Code) Symbol 

SQRC is a QR code with scanning restrictions. SQRC comes in the form of disclosed and undisclosed data. Scanning 
of undisclosed data is possible only if the encryption key set in the scanner matches. In order to perform SQRC 
scanning, it is necessary to either permit scanning of SQRC only, or to permit scanning of SQRC and QR codes. 

(Note)

 

With the SQRC scanning enabled, the parameters for “Encryption key mismatch” and “Encryption key match” can be 
selected with the configuration software.

 

Note:

 Encryption key setting is necessary in order to perform SQRC scanning. In order to set an encryption key(s), 

dedicated SQRC scan setting software (SQRC Setting) is required. 

 

 

Содержание GT10Q-SB

Страница 1: ...2D Code Handy Scanner GT10Q SB User s Manual...

Страница 2: ...oftware not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii any modification of DENSO WAVE s products by other s than...

Страница 3: ...nergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a parti...

Страница 4: ...de Automatic Detection of Labels 12 Chapter 6 Magic Key Control 13 Chapter 7 Scanning Functions 15 7 1 Data Verification Mode 15 7 1 1 Verification setup procedure 15 7 1 2 Specifying a verification o...

Страница 5: ...Cartridge 48 10 2 Replacing the Battery Cartridge 50 Chapter 11 Image Capturing 52 11 1 Outline 52 11 2 Image Capturing Specifications 52 Chapter 12 Parameters and Defaults 54 Chapter 13 QR Coded Par...

Страница 6: ...peedy reference Note The shape of the projected area marker differs according to the original target market This hand held scanner with built in area marker five point is designed for use in the Unite...

Страница 7: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...

Страница 8: ...uld cause battery rupture or leakage of battery fluid and result in a fire bodily injury or serious damage to property Never charge the battery cartridge where any inflammable gases may be emitted doi...

Страница 9: ...to the user LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Handling the scanner and AC adapter Do not put the scanner or AC adapter on an unstable or inclined plane It may drop creating inju...

Страница 10: ...or damp Doing so could result in an electrical shock Never use chemicals or organic solvents such as benzene and thinner to clean the housing Do not apply insecticide to the scanner or AC adapter Doin...

Страница 11: ...rface cable CBBA RS2000 9 6 AC adapter AD1 2005 3600 USA For communications adapter For RS 232C interface and communications adapter mounted in the charger 5 RS 232C interface cable Charger built in t...

Страница 12: ...etworking The following environments can sometimes block wireless networking Metal objects or particles in the vicinity Metal walls around the area Excessive vibration The communications range of 10 m...

Страница 13: ...ore periodically check the clear plate of the code reading window and clean it if dusty To clean the plate first blow the dust away with an airbrush Then wipe the plate with a cotton swab or the simil...

Страница 14: ...r initiate a Bluetooth wireless link The following read modes are available to match the needs of the intended application Auto off mode Momentary switching mode Alternate switching mode Continuous re...

Страница 15: ...n is selected requires scanning the Start operation QR Code symbol Scanning those code symbols enables the Bluetooth interface Note Always disable this scanner s Bluetooth interface in hospitals aircr...

Страница 16: ...rrently a master use the scanner to read the Configure as slave QR Code symbol given in Section 13 2 using the procedure in Section 13 1 to switch it to slave operation 2 Wait for the scanner to beep...

Страница 17: ...etooth address code that specifies the equipment s Bluetooth address to the scanner When using a commercially available code generator generate it in the following format Code type Data format QR Code...

Страница 18: ...re in Section 13 1 Note that when the scanner as a master is searching for a connection target or it is as a slave waiting for a master to connect the magic key can break the Bluetooth wireless link 2...

Страница 19: ...anner has scanned the End operation QR Code symbol When the trigger switch is pressed and released Indicator LED Beeper Scanner Status Blue flashing rapidly The scanner as a master is searching for a...

Страница 20: ...marker beam should be used merely as a guide It does not assure that a code within the marker beam range can be read Note Having more than one code within the field of view either causes the read to...

Страница 21: ...en The scanner can read codes even with the Bluetooth wireless link being broken Use this scanning way when scanning codes is required but data transfer is not for instance when the scanner itself che...

Страница 22: ...g_2D in your computer It is recommended that the scanner be configured as a master This software also offers batch process QR Code symbols for ready by scanners in the field The configuration software...

Страница 23: ...ch time you press the trigger switch the scanner toggles between the ready to scan and standby states 4 Continuous reading mode 1 Establishing the Bluetooth wireless link or selecting the Scan w Bluet...

Страница 24: ...trol the scanner by sending scanning control commands from the host computer via the Bluetooth interface instead of pressing the trigger switch Scanning control commands include R READON LON Z READOFF...

Страница 25: ...ignated range or move a code label within the same range These LEDs go off when a code label is moved away from the range or stays within the range without move for approx 3 seconds The scanner offers...

Страница 26: ...n 3 Specific character transfer function Pressing the magic key transfers a character string max 10 bytes specified with the configuration software ScannerSetting_2D 4 Ready standby switching function...

Страница 27: ...f mode Momentary switching mode Alternate switching mode Continuous reading mode 1 Continuous reading mode 2 Auto sensing mode Readable code switching function Data retransfer function Specific charac...

Страница 28: ...prox 2 seconds The indicator LED should light in green 2 With the magic key held down press the trigger switch to read the master code to be entered The scanner operates in the trigger switch operatin...

Страница 29: ...rification start position No of characters to verify Data string read Verification object Result 345 3 3 00345 Match 345 3 3 00345678 Match 345 3 3 00346 Mismatch 345 3 3 0034 Mismatch 2 Data block ve...

Страница 30: ...ou can enable or disable this function with the configuration software ScannerSetting_2D Once the scanner is locked it switches to standby regardless of the current trigger switch control selected The...

Страница 31: ...h no master data stored To break the Bluetooth wireless link with no master data stored follow the procedure given below Break Bluetooth wireless link Hold down the magic key for at least 2 seconds to...

Страница 32: ...l 7 2 1 1 Extracting a data string The scanner extracts a data string specified by the Extraction start position and Extraction end position from a code specified by the Code type and then outputs it...

Страница 33: ...h position Error 6th position Tail position Error 6th position By 10 positions Error Code type QR Code Data transfer regardless of error result Prohibit 1st position 6th position Error Head position 6...

Страница 34: ...Extraction conditions Choices Any code QR Code PDF Data Matrix MaxiCode UPC A EAN 13 UPC E EAN 8 Code 128 EAN 128 Codabar NW 7 Code 39 Interleaved 2of5 ITF RSS Code type EAN UCC Composite symbology Da...

Страница 35: ...90 2 and 5 STX ETX STX 7890 ETX 1 23 456 7890 5 Error 1 23 456 7890 4 and 5 Error Code type QR Code Data transfer regardless of error result Prohibit 1234567890 1 and 2 Error 1 23 456 7890 5 STX 1 23...

Страница 36: ...ID mark can be also added to each element string if their transmissions are enabled The number of digits is the count of each element string edited Example Data read 01 94901234567894 11 030808 13 030...

Страница 37: ...40208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 01 12 Data transfer regardless of error result Permit 01 01 Comma STX 01949012345678941103080813030810170 4020817040305 ETX Note 1...

Страница 38: ...Extraction conditions Data read Output data 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030808 13 030810 17 040208 ETX Data transfer regardless of error result Prohibit 0194901...

Страница 39: ...e YYMMDD 20 n2 n2 Product Variant 21 n2 an 20 Serial Number 22 n2 an 29 HIBCC Health Industry Business Communication Council Quantity Date Batch and Link 23n n3 n 19 Batch or Lot Number Transitional U...

Страница 40: ...34n n4 n6 Area Square Meters Symbology 335n n4 n6 Gross Volume Liters 336n n4 n6 Gross Volume Cubic Meters 337n n4 n6 Kilograms per Square Meter pressure 340n n4 n6 Gross Weight Pounds 341n n4 n6 Leng...

Страница 41: ...ngle Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Currency Code 400 n3 an 30 Customer s Purchase Order Number 401 n3 an 30 Consignment Number 402 n3 n17 Shipme...

Страница 42: ...ble Asset Identifier GRAI 8004 n4 an 30 EAN UCC Global Individual Asset Identifier GIAI 8005 n4 n6 Price Per Unit of Measure 8006 n4 n14 n2 n2 Identification of the Component of a Trade Item 8007 n4 a...

Страница 43: ...on a a3 a 3 Alphabetic characters 3 alphabetic characters fixed length Up to 3 alphabetic characters n n3 n 3 Numeric characters 3 numeric characters fixed length Up to 3 numeric characters an an3 an...

Страница 44: ...B CR 78 Code ID mark Disable Header STX Terminator ETX Transmission of the number of digits Disable BCC Disable Prefix Suffix None Conversion conditions Output data Code type PDF417 Data transfer rega...

Страница 45: ...be enabled concurrently The one set last will be enabled 7 5 Scanning a Mirror Image 2D Code If you enable the mirror image scanning with the QR coded parameter menu or the configuration software Sca...

Страница 46: ...ead the scanner sends the data read to the host computer When scanning split QR Code symbols the scanner beeps in a different way from usual That is when the scanner reads the first split code symbol...

Страница 47: ...nes of barcode data delimited with commas in the data transmission format selected see Section 9 2 Note that the scanner outputs the code ID mark specified for the first line barcode and the number of...

Страница 48: ...r than a parameter setting code is read from the QR coded parameter menu during a parameter setting sequence a transmission error or timeout has occurred during communication with the configuration so...

Страница 49: ...ansfer is started by the data retransfer function the scanner has read a code successfully with the readable code switching function or barcode reader mode switching function enabled data transfer is...

Страница 50: ...being entered or the entry is completed any error has occurred during entry of a master code the verification result is a mismatch the scanner is locked or no master data has been entered in the data...

Страница 51: ...bol generated with the configuration software ScannerSetting_2D NG vibrations The vibrator operates to indicate any of the following failure conditions Wrong number of digits in data for new master da...

Страница 52: ...conds When the scanner is ready to scan that is while the trigger switch is fully held down in the momentary switching mode or when the scanner is ready to scan in the alternate switching mode the mar...

Страница 53: ...rSetting_2D only provides ACK NAK timeout settings from 100 ms to 9 9 s in 100 ms increments ACK Normal end NAK Retransfer 2 Timeout period for slave to wait for a connection request The scanner as a...

Страница 54: ...fault LF CR LF or ETX For details refer to Chapter 12 2 Prefix Suffix A prefix or suffix consists of up to eight ASCII characters 00h to FFh You can set a prefix or suffix with the configuration softw...

Страница 55: ...gular Z dm Without add on A X0 Linear component A X3 X0 With 2 digit add on Add on None None X1 Note 3 Linear component A X3 X0 UPC A With 5 digit add on Add on None None X2 Note 2 Without add on C X0...

Страница 56: ...th 2 digit add on Add on None None None E1 Note 3 Linear component V A E3 E0 EAN 13 With 5 digit add on Add on None None None E2 Note 3 EAN 13 CC A EAN 13 CC B CC A CC B None Y Note 3 e0 Note 3 Withou...

Страница 57: ...a check digit Check digit transmission enabled Code 39 3 Scanning enabled with a check digit Check digit transmission disabled 0 Scanning enabled without a check digit 1 Scanning enabled with a check...

Страница 58: ...anner transmits the code number the number of splits parity and code data read The code number and the number of splits are 1 byte each and the parity 2 bytes in hexadecimal format SQRC The data conte...

Страница 59: ...ct whether or not to transmit a check digit A code ID mark precedes add on code data under the conditions Code ID mark Type 2 and Code ID mark output mode Separating For details about the code ID mark...

Страница 60: ...acter positions other than the 1st and 2nd ones from the start code will be converted to GS 1Dh and transferred RSS RSS 14 RSS 14 Truncated RSS Limited RSS 14 Stacked RSS Expanded RSS 14 Stacked Omnid...

Страница 61: ...ive vibration No splashing of water or other liquids Do not leave the charger in direct sunlight in an automobile or other location exposed to high temperatures Keep the charger away from telephones t...

Страница 62: ...ffect or Memory Accumulation The memory effect can be avoided by discharging a Ni MH battery fully before recharging i e refreshing using the following procedure 1 Connect the AC adapter to the charge...

Страница 63: ...ke the battery cartridge out of the scanner due to any scanner trouble 1 Remove the screw that secures the battery cover 2 Open the battery cover gently that is connected with the cable 3 Pull up the...

Страница 64: ...e around the battery cartridge to prevent them from getting pinched between the battery cover and the case and then close the battery cover and secure it with the screw Note After loading a new batter...

Страница 65: ...help you aim at a target The thumbnail images can be saved only as a BMP image in 1 64 VGA You can select the output format video mode output image area and whether or not to use a thumbnail by modif...

Страница 66: ...uppercase or numerical ASCII characters Transmission condition settings such as header terminator and transmission speed for the image transmission are the same as those for ordinary commands Upon co...

Страница 67: ...o Scan w Bluetooth link broken Scanning with Bluetooth wireless link broken Cancel Scan w Bluetooth link broken Section 3 2 Regular read mode Data verification mode Scan lock disabled Scanning modes D...

Страница 68: ...RKU Section 2 2 Specification of connection target s address only when local name is specified Connection target s address None Section 2 2 2 minutes 4 minutes 10 minutes Timeout period for slave to...

Страница 69: ...x Code ID mark position After prefix Section 9 2 Type 1 Code ID mark Type 2 Section 9 2 4 Coupling Code ID mark output mode Separating Section 9 2 4 Enable Transmission of the number of digits not app...

Страница 70: ...Data Matrix Square Disable Enable Scanning Data Matrix Rectangular Disable Section 13 2 See Note 1 QR Code min version readable 1 QR Code max version readable 1 to 40 40 MicroQR min version readable...

Страница 71: ...Items Parameters Defaults Refer to Enable Scanning UPC A and EAN 13 Disable Enable Scanning UPC E Disable Enable Scanning EAN 8 Disable Section 13 2 Enable Transmission of a check digit for UPC A Disa...

Страница 72: ...of digits to scan for Codabar NW 7 4 digits Max number of digits to scan for Codabar NW 7 3 to 99 digits including start stop codes 99 digits See Note 1 Enable Transmission of start stop codes for Cod...

Страница 73: ...of both Code 128 and EAN 128 at the same time RSS Composite symbols Items Parameters Defaults Refer to Enable Scanning RSS 14 RSS 14 Truncated RSS 14 Limited RSS Expanded Disable Enable Scanning RSS...

Страница 74: ...scan for the 1st line Max 99 digits Not specified Code type for the 2nd line Selectable from readable bar codes Not specified Heading characters for the 2nd line Up to 2 ASCII characters Not specified...

Страница 75: ...nsibility level in auto sensing mode Low Section 5 4 Data retransfer function Specific character transfer function Readable code switching function Marker mode switching function Ready standby switchi...

Страница 76: ...regardless of error result in data editing Prohibit Data transfer only after successful editing Data string extraction Data block extraction Data extraction mode AI prefixed string extraction Head po...

Страница 77: ...I delimited mode Tab Enable Transmission of ERROR command at the time of scanning failure Disable Section 7 2 Note 2 For details about AI candidates refer to Chapter 7 Section 7 2 1 3 3 AI table 9 Swi...

Страница 78: ...interface with the Start operation QR Code symbol Three beeps Scan parameter setting QR Code symbols If the Bluetooth interface is disabled with the End operation QR Code symbol scan the Start operat...

Страница 79: ...All defaults End setting The beeper volume can be set by scanning the following QR Code symbol only No Start setting or End setting QR Code symbol is required to scan Note that the Start operation of...

Страница 80: ...en Scanning the Scan w Bluetooth link broken QR Code symbol allows the scanner to scan codes with the Bluetooth wireless link being broken With this setting selected data transfer with the host comput...

Страница 81: ...ons parameters Procedure Non acknowledge mode default ACK NAK mode Header None default STX Terminator ETX CR default LF CR LF Timeout period for slave to wait for a connection request 2 minutes defaul...

Страница 82: ...69 Data transmission format Transmission of code ID mark Disable default Enable Transmission of the number of digits Disable default Enable Transmission of BCC Disable default Enable...

Страница 83: ...lack and white inverted codes Black cells bars on white background default White cells bars on black background Automatically identify black and white inverted codes Scanning split QR Code symbols Str...

Страница 84: ...Scanning Data Matrix Disable Enable default Bar codes Scanning UPC A UPC E EAN 13 and EAN 8 Disable Enable default Scanning Interleaved 2of5 Disable Enable without a check digit default Enable with a...

Страница 85: ...nning Codabar NW 7 Disable Enable without a check digit default Enable with a check digit Check digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of s...

Страница 86: ...enabled Enable with a check digit Check digit transmission disabled Transmission of start stop codes for Code 39 Disable default Enable Other settings Trigger switch control Auto off mode default Alte...

Страница 87: ...74 Beeper control Disable Enable default Indicator LED Disable Enable default Vibrator OK vibrations default NG vibrations Disable...

Страница 88: ...o the setup mode Hold down the SETUP button provided on the bottom of the communications adapter for at least 0 5 second with a pin or the like to switch to the setup mode Note Leaving the communicati...

Страница 89: ...ally the scanner s indicator LED turns red with three beeps Both the scanner and communications adapter automatically reset themselves regardless of whether the parameter transfer ends normally Commun...

Страница 90: ...Menu control Starting Ending the Setting Procedure and Reverting to Defaults Start setting Start setting When the White code on black background is set Cancel All defaults End setting Interface USB ke...

Страница 91: ...terface Monitoring CTS USB COM interface Disable Enable default Communications parameters for RS 232C interface Transmission speed RS 232C interface 1200 bps 2400 bps 4800 bps 9600 bps default 14400 b...

Страница 92: ...9 Data bit RS 232C interface 7 bits 8 bits default Parity RS 232C interface None default EVEN ODD Stop bit RS 232C interface 1 bit default 2 bits Monitoring CTS RS 232C interface Disable Enable defaul...

Страница 93: ...e activated Deactivate the power saving function Problem 3 Bar code data not displayed on the computer screen correctly Probable cause What to do The target Bluetooth device is not ready for communica...

Страница 94: ...ly broken Probable cause What to do The automatic disconnection may be enabled Press the trigger switch to reestablish the Bluetooth wireless link Change the timeout period for scanner to wait for a c...

Страница 95: ...ion Blue LED beeper and vibrator Interface Bluetooth Built in wireless module compliant with Bluetooth Specification Ver 1 1 Main power Ni MH battery cartridge Input power requirements Operating volta...

Страница 96: ...l is set to continuous reading mode 1 or 2 R Note 1 Note 2 READON LON Ready to scan Upon receipt of the R READON or LON command the scanner becomes ready to scan as long as the trigger switch control...

Страница 97: ...nd as long as the OK transmission is enabled for a match NG Verification mismatch If code data scanned does not match master data in data verification mode the scanner sends this command as long as th...

Страница 98: ...used to authenticate two Bluetooth devices in pairing Once authentication is performed no Bluetooth passkey input is required for the next authentication Local Name Bluetooth Device Name This is a us...

Страница 99: ...2D Code Handy Scanner GT10Q SB User s Manual First Edition March 2005 Second Edition November 2011 DENSO WAVE INCORPORATED...

Страница 100: ...DENSO WAVE INCORPORATED 1 Yoshiike Kusagi Agui cho Chita gun Aichi Japan 470 2297 http www denso wave com 496899 0370...

Отзывы: