- 82 -
•
Interleaved 2 of 5 (ITF) (I)
[Syntax]
I [:[mini.no.digits[-max.no.digits]][CD]]
The mini.no.digits and max.no.digits are the minimum and maximum numbers of barcode digits to be
read by the BHT, respectively.
These numbers must both be between 2 and 99 (inclusive) and satisfy the following condition:
mini.no.digits
≤
max.no.digits
If both mini.no.digits and max.no.digits are omitted, the default reading range will be from the minimum
number of digits specified at system mode up to 99 digits.
If only max.no.digits is omitted, the BHT will only be able to read as many digits as specified by
mini.no.digits.
CD is used to specify a check digit(s). If C is specified, barcodes are checked based on MOD-10. The
number of check digits is included in the number of digits to be read.
[Ex.] To enable the BHT to scan ITF with mini.no.digits 6, max.no.digits 10, and MOD-10:
[VB] MyScanner.RdType = "I:6-10C"
[C#] MyScanner.RdType = "I:6-10C";
[Ex.] To enable the BHT to scan ITF with mini.no.digits 6 and max.no.digits 10 or with
mini.no.digits 20 and max.no.digits 40:
[VB] MyScanner.RdType = "I:6-10,I:20-40"
[C#] MyScanner.RdType = "I:6-10,I:20-40";
Содержание BHT-400-CE
Страница 1: ...Class Library Reference Manual Bar Code Handy Terminal BHT 400 CE ...
Страница 49: ... 43 17 9 LED UsageCollection This class is invalid at the BHT 400 ...
Страница 66: ... 60 17 26 Display This function is not supported ...
Страница 67: ... 61 17 27 Display Settings This function is not supported ...
Страница 78: ... 72 Events Event Name Description OnDone Occurs when decoding is complete Enumeration None ...
Страница 166: ... 160 18 9 LED UsageCollection This class is invalid on the BHT400 ...
Страница 289: ... 283 18 26 Display This function is not supported ...
Страница 290: ... 284 18 27 Display Settings This function is not supported ...
Страница 296: ... 290 C MySysMod FileName SysModification BHT400New zl MySysMod Mode SysModification EN_MODE POWEROFF MySysMod Execute ...